Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques

被引:142
|
作者
Almeida e Silva, Junio S. [1 ,2 ]
Erdelt, Kurt [2 ]
Edelhoff, Daniel [2 ]
Araujo, Elito [3 ]
Stimmelmayr, Michael [2 ]
Cardoso Vieira, Luiz Clovis [4 ]
Gueth, Jan-Frederik [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Operat Dent, BR-75083350 Anapolis, Go, Brazil
[2] Ludwig Maximilians Univ Munchen, Sch Dent, Dept Prosthodont, Munich, Germany
[3] Univ Fed Santa Catarina, Comprehens Clin, Florianopolis, SC, Brazil
[4] Univ Fed Santa Catarina, Operat Dent Div, Florianopolis, SC, Brazil
关键词
CAD/CAM; Fit; Fixed dental prostheses; Zirconia; Digital impression; Precision; ALL-CERAMIC CROWNS; PROCERA ALLCERAM CROWNS; CLINICAL FIT; IN-VIVO; SYSTEMS; ACCURACY; RESTORATIONS; THICKNESS;
D O I
10.1007/s00784-013-0987-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vitro study was to evaluate the marginal and internal fit of CAD/CAM-generated four-unit zirconia fixed dental prostheses made with digital and conventional impressions. A titanium master model was used. For group conventional impression (CI), 12 polyether impressions of the master model with Impregum(TM) were made. For group digital impression (DI), 12 digital impressions of the master model using Lava(TM) C.O.S. system were made. The replica technique was applied. The Mann-Whitney U statistical test was applied to detect statistical differences between the groups, in terms of marginal and internal fit. Face-by-face comparisons between groups were also carried out. Groups DI and CI presented mean marginal fit of 63.96 and 65.33 mu m, respectively, and showed no statistically significant difference. Groups DI and CI presented significantly different internal fit with mean values of 58.46 and 65.94 mu m, respectively. Group DI showed statistically significantly lower values for marginal and internal fit on premolar mesial face, and on molar distal and palatal faces. Frameworks fabricated from digital and conventional impressions showed clinically acceptable marginal fit. Frameworks fabricated from digital impression demonstrated better internal fit than ones fabricated from conventional impression. Reviewing each retainer face, digital impression showed better marginal and internal fit at the premolar mesial and molar distal faces. The results of this in vitro study show that digital impressions made with the Lava(TM) C.O.S. system and its digital workflow are suitable for fabricating four-unit zirconia frameworks, with regard to marginal and internal fit requirements.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 50 条
  • [1] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Júnio S. Almeida e Silva
    Kurt Erdelt
    Daniel Edelhoff
    Élito Araújo
    Michael Stimmelmayr
    Luiz Clovis Cardoso Vieira
    Jan-Frederik Güth
    Clinical Oral Investigations, 2014, 18 : 515 - 523
  • [2] Clinical fit of four-unit zirconia posterior fixed dental prostheses
    Reich, Sven
    Kappe, Karsten
    Teschner, Hubertus
    Schmitt, Johannes
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (06) : 579 - 584
  • [3] Evaluation of marginal/internal fit of fixed dental prostheses after digital, conventional, and combination impression techniques: A systematic review
    Sarafidou, Katia
    Chatziparaskeva, Maria
    Chatzikamagiannis, Dimitrios
    Mpotskaris, Vasileios
    Tortopidis, Dimitrios
    Bakopoulou, Athina
    Kokoti, Maria
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2022, 130 (06)
  • [4] Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression
    Su, Ting-Shu
    Sun, Jian
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03): : 362 - 367
  • [5] Effect of number of pontics and impression technique on the accuracy of four-unit monolithic zirconia fixed dental prostheses
    Kim, Woong Ki
    Kim, Sunjai
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05): : 860.e1 - 860.e7
  • [6] Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
    Beuer, Florian
    Korczynski, Natalie
    Rezac, Antonia
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2010, 2 : 5 - 11
  • [7] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [8] Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study
    Bayramoglu, Emre
    Ozkan, Yasemin Kulak
    Yildiz, Coskun
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (01): : 52 - 58
  • [9] Digital technique for in vivo assessment of internal and marginal fit of fixed dental prostheses
    Park, Ji-Man
    Hammerle, Christoph H. F.
    Benic, Goran I.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 452 - 454
  • [10] Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
    Svanborg, Per
    Skjerven, Henrik
    Carlsson, Pablo
    Eliasson, Alf
    Karlsson, Stig
    Ortorp, Anders
    INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014