Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques

被引:142
|
作者
Almeida e Silva, Junio S. [1 ,2 ]
Erdelt, Kurt [2 ]
Edelhoff, Daniel [2 ]
Araujo, Elito [3 ]
Stimmelmayr, Michael [2 ]
Cardoso Vieira, Luiz Clovis [4 ]
Gueth, Jan-Frederik [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Operat Dent, BR-75083350 Anapolis, Go, Brazil
[2] Ludwig Maximilians Univ Munchen, Sch Dent, Dept Prosthodont, Munich, Germany
[3] Univ Fed Santa Catarina, Comprehens Clin, Florianopolis, SC, Brazil
[4] Univ Fed Santa Catarina, Operat Dent Div, Florianopolis, SC, Brazil
关键词
CAD/CAM; Fit; Fixed dental prostheses; Zirconia; Digital impression; Precision; ALL-CERAMIC CROWNS; PROCERA ALLCERAM CROWNS; CLINICAL FIT; IN-VIVO; SYSTEMS; ACCURACY; RESTORATIONS; THICKNESS;
D O I
10.1007/s00784-013-0987-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vitro study was to evaluate the marginal and internal fit of CAD/CAM-generated four-unit zirconia fixed dental prostheses made with digital and conventional impressions. A titanium master model was used. For group conventional impression (CI), 12 polyether impressions of the master model with Impregum(TM) were made. For group digital impression (DI), 12 digital impressions of the master model using Lava(TM) C.O.S. system were made. The replica technique was applied. The Mann-Whitney U statistical test was applied to detect statistical differences between the groups, in terms of marginal and internal fit. Face-by-face comparisons between groups were also carried out. Groups DI and CI presented mean marginal fit of 63.96 and 65.33 mu m, respectively, and showed no statistically significant difference. Groups DI and CI presented significantly different internal fit with mean values of 58.46 and 65.94 mu m, respectively. Group DI showed statistically significantly lower values for marginal and internal fit on premolar mesial face, and on molar distal and palatal faces. Frameworks fabricated from digital and conventional impressions showed clinically acceptable marginal fit. Frameworks fabricated from digital impression demonstrated better internal fit than ones fabricated from conventional impression. Reviewing each retainer face, digital impression showed better marginal and internal fit at the premolar mesial and molar distal faces. The results of this in vitro study show that digital impressions made with the Lava(TM) C.O.S. system and its digital workflow are suitable for fabricating four-unit zirconia frameworks, with regard to marginal and internal fit requirements.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 50 条
  • [21] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [22] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [23] Precision of fit: zirconia three-unit fixed dental prostheses
    Florian Beuer
    Michael Naumann
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13
  • [24] Marginal Discrepancy and Internal Fit of Bi-Layered and Monolithic Zirconia Fixed Dental Prostheses: An In Vitro Study
    Alsarani, Majed
    Rizkalla, Amin
    Fava, Joseph
    Coyle, Thomas
    El-Mowafy, Omar
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [25] Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    Kohorst, Philipp
    Brinkmann, Henrike
    Li, Jiang
    Borchers, Lothar
    Stiesch, Meike
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (03) : 319 - 325
  • [26] Accuracy of additively manufactured zirconia four-unit fixed dental prostheses fabricated by stereolithography, digital light processing and material jetting compared with subtractive manufacturing
    Luchtenborg, Jorg
    Willems, Evita
    Zhang, Fei
    Wesemann, Christian
    Weiss, Florian
    Nold, Julian
    Sun, Jinxing
    Sandra, Fabien
    Bai, Jiaming
    Reveron, Helen
    Chevalier, Jerome
    Spies, Benedikt C.
    DENTAL MATERIALS, 2022, 38 (09) : 1459 - 1469
  • [27] Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques
    Nesse, Harald
    Ulstein, Dina Mari Akeryik
    Vaage, Malene Myhre
    Oilo, Marit
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 686 - 692
  • [28] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [29] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Joana Schönberger
    Kurt-Jürgen Erdelt
    Daniel Bäumer
    Florian Beuer
    Clinical Oral Investigations, 2017, 21 : 2629 - 2635
  • [30] Accuracy of digital impressions for three- unit and four-unit implant supported fixed dental prostheses using a novel device
    Kao, Tzu-Yung
    Hsieh, Min-Chieh
    Liao, Chi -Chun
    Chang, Chih-Ling
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) : 702 - 708