Automated detection of lung nodules in CT scans:: Effect of image reconstruction algorithm

被引:51
|
作者
Armato, SG [1 ]
Altman, MB [1 ]
La Rivière, PJ [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
computer-aided diagnosis (CAD); lung nodules; computed tomography; image processing; image reconstruction;
D O I
10.1118/1.1544679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have investigated the effect of computed tomography (CT) image reconstruction algorithm on the performance of our automated lung nodule detection method. Commercial CT scanners offer a choice of several algorithms for the reconstruction of projection data into transaxial images. Different algorithms produce images with substantially different properties that are apparent not only quantitatively, but also through visual assessment. During some clinical thoracic CT examinations, patient scans are reconstructed with multiple reconstruction algorithms. Thirty-eight such cases were collected to form two databases: one with patient projection data reconstructed with the "standard" reconstruction algorithm and the other with the same patient projection data reconstructed with the "lung" reconstruction algorithm. The automated nodule detection method was applied to both databases. This method is based on gray-level-thresholding techniques to segment the lung regions from each CT section to create a segmented lung volume. Further gray-level-thresholding techniques are applied within the segmented lung volume to identify a set of lung nodule candidates. Rule-based and linear discriminant classifiers are used to differentiate between lung nodule candidates that correspond to actual nodules and those that correspond to non-nodules. The automated method that was applied to both databases was exactly the same, except that the classifiers were calibrated separately for each database. For comparison, the classifier then was trained on one database and tested independently on the other database. When applied to the databases in this manner, the automated method demonstrated overall a similar level of performance, indicating an encouraging degree of robustness. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:461 / 472
页数:12
相关论文
共 50 条
  • [31] The influence of CT dose and reconstruction parameters on automated detection of small pulmonary nodules
    Ochs, Robert
    Angel, Erin
    Boedeker, Kirsten
    Petkovska, Iva
    Panknin, Christoph
    Goldin, Jonathan
    Aberle, Denise
    McNitt-Gray, Michael
    Brown, Matthew
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [32] Automated lung segmentation in thoracic CT scans
    Armato, SG
    Maloney, MM
    MacMahon, H
    RADIOLOGY, 1999, 213P : 365 - 365
  • [33] The effect of pulmonary vessel suppression on computerized detection of nodules in chest CT scans
    Gu, Xiaomeng
    Xie, Weiyang
    Fang, Qiming
    Zhao, Jun
    Li, Qiang
    MEDICAL PHYSICS, 2020, 47 (10) : 4917 - 4927
  • [34] Automated System for the Detection of Lung Nodules
    Martinez-Machado, E.
    Perez-Diaz, M.
    Orozco-Morales, R.
    PROGRESS IN ARTIFICIAL INTELLIGENCE AND PATTERN RECOGNITION, 2021, 13055 : 337 - 348
  • [35] Multi-kernel driven 3D convolutional neural network for automated detection of lung nodules in chest CT scans
    Wu, Ruoyu
    Liang, Changyu
    Zhang, Jiuquan
    Tan, Qijuan
    Huang, Hong
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (02) : 1195 - 1218
  • [36] AUTOMATED SCHEME FOR THE DETECTION OF LUNG NODULES
    GIGER, ML
    DOI, K
    MACMAHON, H
    MEDICAL PHYSICS, 1987, 14 (03) : 494 - 494
  • [37] Effect of CAD on Radiologists' Detection of Lung Nodules on Thoracic CT Scans: Analysis of an Observer Performance Study by Nodule Size
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Cascade, Philip N.
    Kazerooni, Ella A.
    Chughtai, Aamer R.
    Poopat, Chad
    Song, Thomas
    Frank, Luba
    Stojanovska, Jadranka
    Attili, Anil
    ACADEMIC RADIOLOGY, 2009, 16 (12) : 1518 - 1530
  • [38] Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules
    Little, K.
    Reiser, I.
    Sanchez, A.
    Chung, J.
    MacMahon, H.
    Lu, Z.
    MEDICAL PHYSICS, 2016, 43 (06) : 3891 - 3891
  • [39] Computerized detection of lung nodules in computed tomography scans
    Armato, SG
    Giger, ML
    Moran, CJ
    Doi, K
    MacMahon, H
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 119 - 123
  • [40] Lung Nodule Detection in CT Scans
    Antonelli, M.
    Frosini, G.
    Lazzerini, B.
    Marcelloni, F.
    PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 1, 2007, 1 : 128 - 131