Electrode-separated Quartz Crystal Microbalance for Smart-sensor Mounting Application

被引:3
|
作者
Sakaguchi, Jun [1 ]
Sohgawa, Masayuki [1 ]
Abe, Takashi [1 ]
机构
[1] Niigata Univ, Grad Sch Sci & Technol, Nishi Ku, 8050 Ikarashi 2 No Cho, Niigata 9502181, Japan
关键词
quartz crystal microbalance; separated electrode; crystallographic x-axis; ACOUSTIC-WAVE SENSOR; PATTERN-RECOGNITION; RESONATOR; ARRAYS;
D O I
10.18494/SAM.2018.1712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Quartz crystal microbalances (QCMs) have found applications as popular chemical and biological sensing tools. However, their current device geometry prevents their commercialization for industrial use. In this study, we propose a new disposable QCM sensor with an electrode only on the sensing side, making it suitable for sensor mounting. In this sensor system, the excitation electrode is positioned on a glass plate separate from the QCM. Such electrode configurations are suitable for sensor applications in flow cell systems in preference to common QCM systems because QCM mounting on the flow cell and the electrical interconnections between the QCM and the oscillation circuit are simple. The optimized configurations of the electrode diameter, separation distance, and orientation relative to the crystallographic x-axis of the plate are revealed for the first time. The proposed QCM can be applied to realize a disposable QCM-based biochip or hazardous gas sensor located inside a flow tube.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [11] In situ monitoring of adsorption of lysozyme onto quartz using an electrode-separated piezoelectric sensor
    Shen, DZ
    Xue, YH
    Kang, Q
    Xie, QJ
    Chen, LX
    MICROCHEMICAL JOURNAL, 1998, 60 (01) : 1 - 7
  • [12] Application of the smart sensors using quartz crystal microbalance
    Noda, Kazutoshi
    Aizawa, Hidenobu
    IEEJ Transactions on Sensors and Micromachines, 2015, 135 (08) : 292 - 298
  • [13] Gravimetric monitoring of adsorption behavior of tetrakis(methylpyrdiniumyl)porphyrin onto quartz crystal surface using an electrode-separated piezoelectric sensor
    Dazhong Shen
    Qingji Xie
    Qi Kang
    Yanhui Xue
    Microchimica Acta, 1998, 128 : 229 - 233
  • [14] ADSORPTION OF METAL-IONS FROM SOLUTIONS ON THE QUARTZ PLATE OF AN ELECTRODE-SEPARATED PIEZOELECTRIC QUARTZ-CRYSTAL
    NOMURA, T
    ISAWA, M
    MATSUZAWA, H
    SHIBUKAWA, Y
    ANALYTICA CHIMICA ACTA, 1994, 286 (02) : 205 - 212
  • [15] Study of cationic polyelectrolyte adsorption onto quartz surface using an electrode-separated piezoelectric sensor
    Wang, LZ
    Huang, HL
    Zhang, P
    Zhao, HZ
    An, ZS
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2002, 79 (01) : 84 - 87
  • [16] Adsorption studies of cationic starch onto quartz surface through an electrode-separated piezoelectric sensor
    Shen, DZ
    Li, SH
    Li, WP
    Zhang, XL
    Wang, LZ
    MICROCHEMICAL JOURNAL, 2002, 71 (01) : 49 - 55
  • [17] FREQUENCY-CHARACTERISTICS OF AN ELECTRODE-SEPARATED PIEZOELECTRIC CRYSTAL SENSOR IN CONTACT WITH A LIQUID
    SHEN, DZ
    LIN, S
    KANG, Q
    NIE, LH
    YAO, SZ
    ANALYST, 1993, 118 (09) : 1143 - 1147
  • [18] An electrode-separated piezoelectric sensor as a surface monitoring technique for anionic surfactant adsorption on quartz surface
    Shen, DZ
    Kang, Q
    Zhang, XL
    Li, WP
    Liu, ZC
    MIKROCHIMICA ACTA, 2002, 138 (1-2) : 89 - 93
  • [19] Indirect determination of copper(II) in aqueous solution using an electrode-separated piezoelectric quartz crystal
    Kato, Y
    Maekawa, A
    Nomura, T
    BUNSEKI KAGAKU, 2003, 52 (03) : 165 - 170
  • [20] Gravimetric Monitoring of Adsorption Behavior of Tetrakis(methylpyrdiniumyl)porphyrin onto Quartz Crystal Surface Using an Electrode-separated Piezoelectric Sensor
    Shen, Dazhong
    Xie, Qingji
    Kang, Qi
    Xue, Yanhui
    Mikrochimica Acta, 1998, 128 (03): : 229 - 233