A Passive Wireless Crack Sensor Based on Patch Antenna with Overlapping Sub-Patch

被引:26
|
作者
Xue, Songtao [1 ,2 ]
Yi, Zhuoran [1 ]
Xie, Liyu [1 ,3 ]
Wan, Guochun [4 ]
Ding, Tao [5 ]
机构
[1] Tongji Univ, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[2] Tohoku Inst Technol, Dept Architecture, Sendai, Miyagi 9828577, Japan
[3] Tongji Univ, Minist Educ, Key Lab Performance Evolut & Control Engn Struct, Shanghai 200092, Peoples R China
[4] Tongji Univ, Dept Elect Sci & Technol, Shanghai 200092, Peoples R China
[5] Tongji Univ, Sch Phys Sci & Engn, Inst Precis Opt Engn, Shanghai 200092, Peoples R China
关键词
passive wireless sensor; patch antenna; crack width monitoring; covered radiation patch;
D O I
10.3390/s19194327
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monolithic patch antennas for deformation measurements are designed to be stressed. To avoid the issues of incomplete strain transfer ratio and insufficient bonding strength of stressed antennas, this paper presents a passive wireless crack sensor based on an unstressed patch antenna. The rectangular radiation patch of the proposed sensor is partially covered by a radiation sub-patch, and the overlapped length between them will induce the resonate frequency shift representing the crack width. First, the cavity model theory is adopted to show how the resonant frequencies of the crack sensor are related to the overlapped length between the patch antenna and the sub-patch. This phenomenon is further verified by numerical simulation using the Ansoft high-frequency structure simulator (HFSS), and results show a sensitivity of 120.24 MHz/mm on average within an effective measuring range of 1.5 mm. One prototype of proposed sensor was fabricated. The experiments validated that the resonant frequency shifts are linearly proportional to the applied crack width, and the resolution is suitable for crack width measuring.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A bolt loosening detection method based on patch antenna with overlapping sub-patch
    Xue, Songtao
    Li, Xianzhi
    Xie, Liyu
    Yi, Zhuoran
    Wan, Guochun
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2022, 21 (05): : 2231 - 2243
  • [2] An off-center fed patch antenna with overlapping sub-patch for simultaneous crack and temperature sensing
    Li, Xianzhi
    Xue, Songtao
    Xie, Liyu
    Wan, Guochun
    Wan, Chunfeng
    SMART MATERIALS AND STRUCTURES, 2022, 31 (09)
  • [3] A miniaturized passive wireless patch antenna sensor for structural crack sensing
    Li, Xianzhi
    Xue, Songtao
    Xie, Liyu
    Wan, Guochun
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024, 23 (05): : 3276 - 3295
  • [4] A wireless passive pressure sensor based on aperture coupled microstrip patch antenna
    Guo, YanJie
    Tan, QiuLin
    Lu, Fei
    Wu, GuoZhu
    Zhang, Lei
    SENSOR REVIEW, 2018, 38 (02) : 156 - 162
  • [5] Thermally Stable Wireless Patch Antenna Sensor for Strain and Crack Sensing
    Li, Dan
    Wang, Yang
    SENSORS, 2020, 20 (14) : 1 - 13
  • [6] Analysis of the Influence of Patch Antenna Shapes for Wireless Passive Temperature Sensor Applications
    Azahra, Trisa
    Liao, Ying-Ting
    Chen, Yi-Chien
    Kuo, Cheng-Chien
    APPLIED SCIENCES-BASEL, 2025, 15 (06):
  • [7] Simultaneous crack and temperature sensing with passive patch antenna
    Li, Xianzhi
    Xue, Songtao
    Xie, Liyu
    Wan, Guochun
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024, 23 (03): : 1299 - 1312
  • [8] Crack sensor based on patch antenna fed by capacitive microstrip lines
    Xue, Songtao
    Xu, Kangqian
    Xie, Liyu
    Wan, Guochun
    SMART MATERIALS AND STRUCTURES, 2019, 28 (08)
  • [9] Passive Inclination Sensor Based on a Patch Antenna with a Reconfigurable Water Load
    Yi, Zhuoran
    Xia, Zihan
    Li, Xianzhi
    Xu, Kangqian
    Xie, Liyu
    Xue, Songtao
    Wu, Yiyu
    SENSORS, 2024, 24 (20)
  • [10] Battery-free slotted patch antenna sensor for wireless strain and crack monitoring
    Yi, Xiaohua
    Cho, Chunhee
    Wang, Yang
    Tentzeris, Manos M.
    SMART STRUCTURES AND SYSTEMS, 2016, 18 (06) : 1217 - 1231