摘要
Drug monitoring of low molecular weight heparin is generally not recommended, but could be reasonable in critically ill patients, whose risk for bleeding or thrombosis shows a high interpatient variability. Anti-Xa assays are not available around the clock even in central hospitals, whereas rotational thrombelastometry (ROTEM) becomes increasingly used at the bedside. Prothrombinase-induced clotting time (PiCT) reagent allows determination of factor Xa-inhibition in plasma. The aim of our study was to evaluate enoxaparin determination in whole blood with the ROTEM using specific test modifications, including PiCT. After ethics committee's approval, citrated whole blood obtained from overall 16 healthy volunteers was incubated with enoxaparin at 16 different anti-Xa concentrations. Main endpoint was the clotting time (CT) in ROTEM representing initial activation of clot formation. CT was determined in the new PiCT-ROTEM test, in a low-tissue factor-activated modification (LowTF-ROTEM) as well as in the commercially available heparin-sensitive ROTEM assays (HEPTEM and INTEM). In the absence of enoxaparin, CT values were 168.6 +/- 6.1 s (PiCT-ROTEM), 247.3 +/- 18.6 s (LowTF-ROTEM), and -6.2 +/- 7.9 s (INTEM-HEPTEM). A linear dependency (P < 0.01) between anti-Xa concentration and CT was found for PiCT-ROTEM, LowTF-ROTEM, and for INTEM-HEPTEM with correlation coefficients of 0.93 for PiCT-ROTEM, 0.94 for LowTF-ROTEM, and 0.81 for INTEM-HEPTEM. This in-vitro experiment demonstrates a strong correlation between enoxaparin anti-Xa concentrations and specific ROTEM tests. These promising assays should be further evaluated for monitoring anticoagulation in high-risk patients in clinical studies. Blood Coagul Fibrinolysis 21:256-261 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [31] Determination of the Procoagulant Activity of Extracellular Vesicle (EV) Using EV-Activated Clotting Time (EV-ACT)
    Gao, Yalong
    Li, Kaiji
    Qin, Qiong
    Zhang, Jianning
    Liu, Li
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (198):
  • [32] Hirudin monitoring using the TAS ecarin clotting time in patients with heparin-induced thrombocytopenia type II
    Koster, A
    Hansen, R
    Grauhan, O
    Hausmann, H
    Bauer, M
    Hetzer, R
    Kuppe, H
    Mertzlufft, F
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (03) : 249 - 252
  • [33] REAL-TIME MEASUREMENTS OF ROTATIONAL-DYNAMICS USING RAMAN-INDUCED POLARIZATION SPECTROSCOPY
    PRICE, WD
    MORGEN, MM
    LUDOWISE, PD
    CHEN, Y
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 178 - PHYS
  • [34] On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system
    Song, Helen
    Li, Hung-Wing
    Munson, Matthew S.
    Van Ha, Thuong G.
    Ismagilov, Rustem F.
    ANALYTICAL CHEMISTRY, 2006, 78 (14) : 4839 - 4849
  • [35] Suitable reference genes determination for real-time PCR using induced sputum samples
    Moermans, Catherine
    Deliege, Esteban
    Pirottin, Dimitri
    Poulet, Christophe
    Guiot, Julien
    Henket, Monique
    da Silva, Jane
    Louis, Renaud
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54 (06)
  • [36] Identification and Determination of the Bloodstains Dry Time in the Crime Scenes Using Laser-Induced Breakdown Spectroscopy
    Wang, Qianqian
    Teng, Geer
    Zhao, Yu
    Cui, Xutai
    Wei, Kai
    IEEE PHOTONICS JOURNAL, 2019, 11 (03):
  • [37] Determination of soot particle size using time-gated laser-induced incandescence images
    Linghong Chen
    Jian Wu
    Mingming Yan
    Xuecheng Wu
    Gérard Gréhan
    Kefa Cen
    Applied Physics B, 2017, 123
  • [38] Determination of soot particle size using time-gated laser-induced incandescence images
    Chen, Linghong
    Wu, Jian
    Yan, Mingming
    Wu, Xuecheng
    Grehan, Gerard
    Cen, Kefa
    APPLIED PHYSICS B-LASERS AND OPTICS, 2017, 123 (04):
  • [39] Suitable Reference Gene Determination for Real Time Polymerase Chain Reaction (PCR) Using Induced Sputum Samples
    Moermans, C.
    Deliege, E.
    Pirottin, D.
    Poulet, C.
    Guiot, J.
    Henket, M.
    Da Silva, J.
    Louis, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [40] Determination of Stark Shifts and Widths Using Time Resolved Laser-Induced Breakdown Spectroscopy (LIBS) Measurements
    Kumar, Prashant
    Soumyashree, Swetapuspa
    Rao Epuru, Nageswara
    Banerjee, Swaroop B.
    Singh, R. P.
    Subramanian, K. P.
    APPLIED SPECTROSCOPY, 2020, 74 (08) : 913 - 920