APD arrays for scintillating fiber readout

被引:0
|
作者
Grazioso, RF [1 ]
Farrell, R [1 ]
Cirignano, L [1 ]
Shah, K [1 ]
机构
[1] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An investigation is underway to determine the feasibility of planar processed, high gain, silicon avalanche photodiode arrays as a readout mechanism for scintillating fibers (SCIFI). Avalanche photodiode (APD) arrays are a compact and rugged alternative to photomultiplier tubes (PMTs). Since SCIFI usually yield a small number of photons compared with bulk scintillators, one goal of this investigation was to determine the photon detection threshold of the APD arrays. A Monte Carlo code was used to simulate a minimum ionizing particle (MIP) interacting with the fiber. The number of photons produced that reach the fiber ends from a MIP was calculated to be between 40-70 photons. The number of photons that reach the fiber ends is dependent on where the MIP interacts along the fiber length, the attenuation length of the fiber, and the fiber length. The next step was to determine the photon detection threshold of an APD array when cooled to -35 degrees C. This was accomplished by using a pulsed LED and a Sr-90 beta source. The experimental data show that our APD arrays have a detection efficiency of nearly 100% for photon pulses of >30 photons at a wavelength of 492nm.
引用
收藏
页码:722 / 724
页数:3
相关论文
共 50 条
  • [31] The CHORUS scintillating fiber tracker and opto-electronic readout system
    Annis, P
    Aoki, S
    Brooijmans, G
    Brunner, J
    Dupraz, J
    Dupont, J
    Fabre, JP
    Favart, D
    Flegel, W
    Frekers, D
    Gregoire, G
    Gruwe, M
    Herin, J
    Hoepfner, K
    Kobayashi, M
    Konijn, J
    Kozaki, T
    Lamonte, P
    Lemaitre, V
    Lendermann, P
    Macina, D
    Drees, RM
    Michel, L
    Mommaert, C
    Nakamura, K
    Nakamura, M
    Nakano, T
    Nappey, P
    Niwa, K
    Niu, E
    Panman, J
    Pintus, R
    Riccardi, F
    Reynaud, S
    Rondeshagen, D
    Sato, O
    Stefanini, G
    Van Beek, G
    Vander Donckt, M
    Vilain, P
    Weinheimer, C
    Wilquet, G
    Winter, K
    Wong, HT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (01): : 19 - 37
  • [32] Test results of an electromagnetic calorimeter with 0.5 mm scintillating fiber readout
    Badier, J.
    Bouhemaid, N.
    Buontempo, S.
    Busson, P.
    Caloba, L.
    Cattaneo, P.
    Charlot, C.
    Chekhtman, A.
    Cousinou, M.C.
    Dagoret, S.
    Dell'Acqua, A.
    Ereditato, A.
    Ferrari, R.
    Fouchez, D.
    Fredj, L.
    Fumagalli, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A337 (2-3) : 314 - 325
  • [33] Si-PIN photodiode readout for a scintillating optical fiber dosimeter
    Rego, Florbela
    Peralta, Luis
    RADIATION MEASUREMENTS, 2012, 47 (10) : 947 - 950
  • [34] CHARACTERISTICS OF SCINTILLATING FIBER ELECTROMAGNETIC CALORIMETERS WITH WAVELENGTH-SHIFTER READOUT
    ARIMA, T
    ASANO, Y
    MIURA, M
    MORI, S
    TAKASAKI, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (03): : 417 - 424
  • [35] Single and multichannel scintillating fiber dosimeter for radiotherapic beams with SiPM readout
    Berra, A.
    Ferri, A.
    Novati, C.
    Ostinelli, A.
    Paternoster, G.
    Piemonte, C.
    Prest, M.
    Vallazza, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 838 : 1 - 11
  • [36] PRELIMINARY-RESULTS ON THE USE OF AVALANCHE PHOTODIODES FOR SCINTILLATING FIBER READOUT
    SALOMON, M
    KITCHING, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 140 - 143
  • [37] A beam hodoscope based on a scintillating-fiber array with multianode photomultiplier readout
    Dreossi, D
    Akchurin, N
    Bravar, A
    Giacomich, R
    Gregori, M
    Gulmez, E
    Iori, M
    Kaya, M
    Lamberto, A
    Newsom, C
    Northacker, D
    Onel, Y
    Ozel, E
    Ozkorucuklu, S
    Penzo, A
    Pogodin, P
    Rappazzo, GF
    Reia, S
    Schiavon, P
    Venier, G
    Winsor, R
    SCIFI 97: CONFERENCE ON SCINTILLATING FIBER DETECTORS, 1998, 450 : 286 - 293
  • [38] A HIGH-RESOLUTION SCINTILLATING FIBER (SCIFI) TRACKING DEVICE WITH CCD READOUT
    ATKINSON, MN
    CRENNELL, DJ
    FISHER, CM
    HUGHES, PT
    KIRKBY, J
    FENT, J
    FREUND, P
    OSTHOFF, A
    PRETZL, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (2-3): : 333 - 342
  • [39] STUDIES OF A NEW 16 CHANNEL PHOTOMULTIPLIER TUBE FOR SCINTILLATING AND WAVESHIFTING FIBER READOUT
    WEISENBERGER, A
    DAY, A
    KROSS, B
    MAJEWSKI, S
    WOJCIK, R
    ZORN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (2-3): : 500 - 508
  • [40] SIGNAL READOUT FROM SCINTILLATING-FIBER BY USING MULTIANODE PHOTOMULTIPLIER TUBES
    MURAKAMI, A
    YOSHINAKA, H
    SAHU, SK
    MAKI, A
    YAMAGUCHI, H
    ZHANG, NS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 490 - 494