ETAAS determination of lead with on-line preconcentration using a flow-through electrochemical microcell

被引:0
|
作者
Bulska, E [1 ]
Jedral, W [1 ]
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An on-line electrodeposition method in a flow-through microcell of 3-mu L volume coupled to an electrothermal atomic absorption spectrometer (ETAAS) was del-eloped for the preconcentration and determination of lead. The method was used for the determination of ultratrace levels of lead in high purity reagents (NaCl, Na2SO4). The system offers the high efficiency of the deposition (over 70%) and dissolution in 40 mu L eluent. The determination is free from interference, since the analyte is separated from the bulk matrix. A detection limit (3 sigma) of 1.2 ng/L was achieved with a 3-minute preconcentration step, The relative standard deviation (n=12) was 4.6% at the 100-ng/L level.
引用
收藏
页码:202 / 205
页数:4
相关论文
共 50 条
  • [31] Flame atomic absorption determination of lead through on-line preconcentration by surfactant mediated glass wool retention
    Katsaounos, CZ
    Paleologos, EK
    Karayannis, MI
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2006, 86 (1-2) : 45 - 52
  • [32] On-line coupling of electrochemical preconcentration in tungsten coil electrothermal atomic absorption spectrometry for determination of lead in natural waters
    Barbosa, F
    Krug, FJ
    Lima, EC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) : 1155 - 1166
  • [33] Flow injection spectrophotometry of lead(II) by on-line preconcentration method using silica capillary tube
    Watanabe, Kunihiro
    Ichihara, Fumitaka
    Itagaki, Masayuki
    BUNSEKI KAGAKU, 2006, 55 (08) : 579 - 585
  • [34] Electrothermal atomic absorption spectrometric determination of cadmium and lead in blood using flow injection on-line sorption preconcentration in a knotted reactor
    Ivanova, E
    Van Mol, W
    Adams, F
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) : 1041 - 1048
  • [35] A flow injection-ETAAS system for the on-line determination of total and dissolved silica in waters
    Burguera, M
    Burguera, JL
    Carrero, P
    Rondón, C
    TALANTA, 2002, 58 (06) : 1157 - 1166
  • [36] Recessed microelectrode array for a micro flow-through system allowing on-line multianalyte determination in vivo
    Lenigk, R
    Zhu, HX
    Lo, TC
    Renneberg, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2): : 66 - 71
  • [37] Recessed microelectrode array for a micro flow-through system allowing on-line multianalyte determination in vivo
    R. Lenigk
    H. Zhu
    Tai-Chin Lo
    Reinhard Renneberg
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 66 - 71
  • [38] Electrochemical Oxidation of Phenol using a Flow-through Micro-porous Lead Dioxide/Lead Cell
    Ferg, Ernst E.
    Gouws, Shawn
    Pongoma, Basanda
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2012, 65 : 165 - 173
  • [39] High temporal resolution monitoring of fermentations using an on-line amperometric flow-through microdetector
    Zor, Kinga
    Gaspar, Szilveszter
    Hashimoto, Masatoshi
    Suzuki, Hiroaki
    Csoregi, Elisabeth
    ELECTROANALYSIS, 2007, 19 (01) : 43 - 48
  • [40] Determination of lead in wine by the FIAS-FAAS combination on-line preconcentration system
    Sun, XJ
    Welz, B
    Sperling, M
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1996, 17 (08): : 1219 - 1221