Current sensor fault detection by bilinear observer for a doubly fed induction generator

被引:0
|
作者
Rothenhagen, Kai [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Chair Power Elect & Elect Dr, Kaiserstr 2, D-24143 Kiel, Germany
来源
IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11 | 2006年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A Bilinear Observer is presented to detect current sensor faults in a doubly fed induction generator. The state space model is derived from the voltage equations of stator and rotor. The bilinear behaviour of induction machines and its influence on the state space model is discussed. An open loop model suffers from model and parameter uncertainty. A closed loop observer is shown to greatly reduce these effects. Observer pole placement is mentioned. Feeding back rotor currents only, the observer becomes independent from stator current measurements. The resulting free residuals can be used for sensor fault detection. The observer is validated by laboratory experiment.
引用
收藏
页码:2475 / +
页数:2
相关论文
共 50 条
  • [41] Parameterization of a synchronous generator to represent a doubly fed induction generator with chopper protection for fault studies
    Martinez, Jorge
    Kjaer, Philip C.
    Rodriguez, Pedro
    Teodorescu, Remus
    WIND ENERGY, 2011, 14 (01) : 107 - 118
  • [42] Actuator Fault Diagnosis Approach for Doubly Fed Induction Generator of Wind Turbine
    Idrissi, I.
    Chafouk, H.
    El Bachtiri, R.
    2019 4TH CONFERENCE ON CONTROL AND FAULT TOLERANT SYSTEMS (SYSTOL), 2019, : 378 - 383
  • [43] A Novel Doubly Fed Induction Generator System with Fault Ride through Capability
    Jiang, Yang
    Huang, Xiaoyan
    Fang, Youtong
    Gerada, Chris
    Goodman, Andrew
    2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012), 2012,
  • [44] Fault Identification in Doubly fed Induction Generator using FFT and Neural Networks
    Patrício de Santana M.
    Boffino de Almeida Monteiro J.R.
    Silva Borges F.A.
    Teixeira de Paula G.
    Portes de Almeida T.E.
    de Andrade Pereira W.C.
    de Castro A.G.
    Journal of Control, Automation and Electrical Systems, 2017, 28 (2) : 228 - 237
  • [45] Unbalanced fault diagnosis of rotor winding in doubly-fed induction generator
    Ma H.-Z.
    Li S.-Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (02): : 138 - 143
  • [46] A fault ride through scheme for doubly fed induction generator wind turbine
    Ling Y.
    Ling, Yu (pleasurely@126.com), 2018, Taylor and Francis Ltd. (15): : 71 - 79
  • [47] A Stator Voltage Oriented Doubly Fed Induction Generator Control Method with a Disturbance Observer
    Ozsoy, E. Emre
    Golubovic, Edin
    Sabanovic, Asif
    Gokasan, Metin
    2013 IEEE EUROCON, 2013, : 1102 - 1107
  • [48] Sensorless Control of Stand-Alone Doubly Fed Induction Generator with an Adaptive Observer
    Forchetti, Daniel G.
    Garcia, Guillermo O.
    Valla, Maria I.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 2465 - +
  • [49] Fault Diagnosis based on Current Signature Analysis for Stator Winding of Doubly Fed Induction Generator in Wind Turbine
    Wang, Lulu
    Zhao, Yong
    Jia, Wei
    Han, Bin
    Liu, Yiying
    Tanaka, Toshikatsu
    Cheng, Yonghong
    Chen, Yu
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 233 - 236
  • [50] Research on Rotor Over-current of a Doubly-Fed Induction Generator Under Power Grid Fault
    Chen, Zhuo
    Hao, Zhenghang
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 397 - +