Fracture resistance of endodontically treated teeth restored with composite posts

被引:243
|
作者
Newman, MP
Yaman, P
Dennison, J
Rafter, M
Billy, E
机构
[1] Univ Michigan, Sch Dent, Dept Cariol Endodont & Restorat Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Dent, Dept Prosthodont, Ann Arbor, MI 48109 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 89卷 / 04期
关键词
D O I
10.1067/mpr.2003.75
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The most recent application of fiber-reinforced composites involves their use as post and core systems to restore endodontically treated teeth. Even though this last application has been advertised and used clinically by many dentists, there is very little information regarding the physical properties of these post systems. Purpose. The purpose of this study was to compare the effect of 3 fiber-reinforced composite post systems on the fracture resistance and mode of failure of endodontically treated teeth. Material and methods. Ninety maxillary central incisors were divided into 8 experimental groups and I stainless steel (ParaPost) control group of 10 specimens each. Eighty teeth were assigned to 2 main experimental groups called "narrow" and "flared" canals. For the narrow canal group, post spaces were prepared with the corresponding reamer to restore the teeth with FibreKor, Luscent anchors, and Ribbond posts of 1.5 mm, 1.6 mm, and 2.0 mm in diameter, respectively. For the flared canals group thin-walled canals were simulated. Teeth for the flared canals were restored with the same posts but were cemented into tapered 2 mm wide canals created with a tapered diamond bur. Prefabricated posts (FibreKor and Luscent anchors) for narrow and flared canals were cemented with an autopolymerized resin cement and a flowable composite, respectively, whereas customized Ribbond posts were luted with a light-polymerized flowable composite for both canal types. An additional set of 20 Ribbond posts with coronal portions of variable size and shape referred to as "Ribbond nonstandardized" were also prepared and evaluated. Specimens were loaded to failure (kg) with a universal testing machine at a crosshead speed of 0.05 cm/min until failure occurred. Data were analyzed with analysis of variance and Student t tests (P<.05). Results. Statistical analysis revealed no significant difference between flared and narrow canals in mean load to failure between the post systems except for the Ribbond posts (P<.01). For the narrow canal, the mean load ranged from a low of 4.55 (+/-1.49) kg for the Ribbond standard to a high of 12.9 (+/-1.64) kg for the Luscent anchors. For the flared canal the low mean was 9.04 (+/-1.76) kg for FibreKor and the high was equal for both Luscent anchors and Ribbond standard, 12.87 (+/-2.69) and 12.87 (+/-3.54), respectively. Overall, the ParaPost control group had the highest load value (18.33 +/- 3.27 kg) (P<.05). Ribbond nonstandardized had a mean load to failure of 24.91 (+/-11.53) Kg for the narrow canal group and 31.95 (+/-11.98) kg for the flared canal. Results from these groups were excluded from the statistical analysis because of the uncontrolled core sizes and high standard deviations. No root fractures occurred in any of the experimental groups. Conclusion. Results from the study show that the load to failure of the stainless steel posts were significantly stronger than all the composite posts studied. However, the mode of failure or deflection of the fiber-reinforced composite posts is protective to the remaining tooth structure.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 50 条
  • [31] Fracture resistance of endodontically treated teeth
    Carlini, B
    Paulillo, LAMS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1149 - 1149
  • [32] RESISTANCE TO FRACTURE OF RESTORED ENDODONTICALLY TREATED PREMOLARS
    TROPE, M
    MALTZ, O
    LANGER, I
    TRONSTAD, L
    JOURNAL OF ENDODONTICS, 1985, 11 (03) : 143 - 143
  • [33] Fracture Resistance of Cast Metal and Zirconia Posts on Endodontically Treated Teeth: An in Vitro Study
    Olloni, Tetore
    Staka, Gloria
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2022, 12 (04) : 606 - 610
  • [34] Cast coverage vs. composite restoration of endodontically treated teeth restored with fiber posts.
    Mannocci, F
    Watson, TF
    Sherriff, M
    Bertelli, E
    Ford, TRP
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 477 - 477
  • [35] Fracture resistance of endodontically treated teeth restored with ceramic inlays and different base materials
    Saridag, Serkan
    Sari, Tugrul
    Ozyesil, Atilla Gokhan
    Aydinbelge, Hale Ari
    DENTAL MATERIALS JOURNAL, 2015, 34 (02) : 175 - 180
  • [36] FRACTURE RESISTANCE OF ENDODONTICALLY TREATED TEETH RESTORED WITH GLASS FIBER REINFORCED POSTS AND CAST GOLD POST AND CORES CEMENTED WITH THREE CEMENTS
    Torres-Sanchez, Carlos
    Montoya-Salazar, Vanessa
    Cordoba, Paola
    Velez, Claudia
    Guzman-Duran, Andres
    Gutierrez-Perez, Jose-Luis
    Torres-Lagares, Daniel
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02): : 127 - 133
  • [37] Fracture resistance of endodontically treated molars restored with extensive composite resin restorations
    Plotino, Gianluca
    Buono, Laura
    Grande, Nicola M.
    Lamorgese, Vincenzo
    Somma, Francesco
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (03): : 225 - 232
  • [38] COMPARISON OF THE FRACTURE RESISTANCE OF ENDODONTICALLY TREATED TEETH RESTORED WITH DIRECT COMPOSITE RESTORATIONS VERSUS ENDOCROWNS- AN IN VITRO STUDY
    Marinescu, Adrian George
    Abuabboud, Osama
    Nica, Luminita-Maria
    Cirligeriu, Laura-Elena
    Rotar, Raul
    Cornacchia, Simona
    Stoia, Dan-Ioan
    Jivanescu, Anca
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2023, 15 (03): : 69 - 79
  • [39] Evaluation of fracture resistance of endodontically treated teeth restored with composite resin along with fibre insertion in different positions in vitro
    Rahman, Hena
    Singh, Shailja
    Chandra, Anil
    Chandra, Ramesh
    Tripathi, Supratim
    AUSTRALIAN ENDODONTIC JOURNAL, 2016, 42 (02) : 60 - 65
  • [40] RESISTANCE TO CUSP FRACTURE IN ENDODONTICALLY TREATED TEETH
    WENDT, SL
    HARRIS, BM
    HUNT, TE
    DENTAL MATERIALS, 1987, 3 (05) : 232 - 235