The Detection of Mercury in Solutions After Thermal Desorption-Enrichment by Energy Dispersive X-Ray Fluorescence

被引:0
|
作者
Ni Zi-yue [1 ]
Cheng Da-wei [2 ]
Liu Ming-bo [2 ]
Yue Yuan-bo [2 ]
Hu Xue-qiang [2 ]
Chen Yu [2 ]
Li Xiao-jia [1 ,2 ]
机构
[1] Cent Iron & Steel Res Inst, Beijing 100081, Peoples R China
[2] NCS Testing Technol Co Ltd, Beijing 100094, Peoples R China
关键词
Energy dispersive X-ray fluorescence; Mercury; Thermal desorption-enrichment; Sewage;
D O I
10.3964/j.issn.1000-0593(2022)04-1117-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
After designing a thermal desorption-enrichment device, the mercury in the solution could be enriched, and the sensitivity could be improved when tested by X-ray fluorescence. The test process was as follows: mercury would be desorbed at high temperature and then adsorbed selectively into the filter membrane when passing through it. After that, the membrane was tested with a spectrometer to calculate the concentration of mercury in sample finally. The thermal reduction temperature of mercury can be lowered by increasing the residence time by adding dolomite into the thermal pipeline, and in the presence of a mercury stabilizer, the desorption can be realized by heating to 600 degrees C. At the same time, the test conditions of the thermal desorption-enrichment were studied, the thermal-desorption time and the test time for the spectral instrument were chosen, the injection volume and the gas flow rate of pumping were optimized. The signal amplified apparently for this method compared with testing directly and increased with the increase of sample volume, which was 11. 78 times higher when the injection volume was 200 mu L. Different mercury concentrations were used to draw the calibration curves, and the linear correlation coefficient was 0. 993 7. A solution was tested 11 times with 0. 05 1 mu g . mL (1) and the relative standard deviation was 4. 048%. When a blank solution was tested, the detection limit and quantification limit were calculated as 0. 004 mu g . mL (1) concentration and 0. 015 mu g . mL (1) respectively. Mixed solutions were prepared to study the interferences of other ions. The results showed that mercury would not be affected by other ions even when their concentrations were up to 100 times. The river water and tap water were collected, and the standard recovery rate of this method was tested, which was between 94. 3% and 102. 6%. The device can improve the detection limit for X-ray fluorescence and detect mercury in sewage.
引用
收藏
页码:1117 / 1121
页数:5
相关论文
共 13 条
  • [1] Selective Detection of Sub-hundred Picomolar Mercuric Ion in Aqueous Systems by Visible Spectrophotometry Using Gripe Water Functionalized Gold Nanoparticles
    Anitha, R.
    Rajarajeswari, G. R.
    [J]. JOURNAL OF CLUSTER SCIENCE, 2019, 30 (04) : 907 - 917
  • [2] [Anonymous], GBT57502
  • [3] Betty Bbosa Naziriwo, 2010, LAKES RESERV, V15, P101
  • [4] Assay of Total Mercury in Commercial Food Supplements of Marine Origin by Means of DLLME/ICP-AES
    Bidari, Araz
    Ganjali, Mohammad Reza
    Assadi, Yaghoub
    Kiani, Armin
    Norouzi, Parviz
    [J]. FOOD ANALYTICAL METHODS, 2012, 5 (04) : 695 - 701
  • [5] Grieb Thomas M, 1990, ENVIRON TOXICOL CHEM, V9, P919
  • [6] Jaroslav Svehla, 2019, SPECTROCHIMICA ACT B, V156, P51
  • [7] Chemical Analysis of Hydroxyapatite Artificial Bone Powders by Energy Dispersive X-Ray Fluorescence Spectrometry (EDXRF)
    Koksal, O. K.
    Apaydin, G.
    Cengiz, E.
    Samek, L.
    Karahan, I. H.
    Tozar, A.
    Lankosz, M.
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (08) : 2645 - 2649
  • [8] A new fully automated on-line digestion system for ultra trace analysis of mercury in natural waters by means of FI-CV-AFS
    Leopold, K.
    Harwardt, L.
    Schuster, M.
    Schlemmer, G.
    [J]. TALANTA, 2008, 76 (02) : 382 - 388
  • [9] Mercury determination at trace levels using membrane preconcentration and benchtop total reflection X-ray fluorescence analysis
    Margui, E.
    Queralt, I.
    Guerra, M.
    Kallithrakas-Kontos, N.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 149 : 84 - 90
  • [10] Determination of total mercury in seafood by ion-selective electrodes based on a thiol functionalized ionic liquid
    Miao, Juan
    Wang, Xin
    Fan, Yunchang
    Li, Jing
    Zhang, Lina
    Hu, Guitao
    He, Can
    Jin, Can
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2018, 26 (02) : 670 - 677