Tribofilm formation in biotribocorrosion - does it regulate ion release in metal-on-metal artificial hip joints?

被引:20
|
作者
Yan, Y. [1 ]
Neville, A. [1 ]
Dowson, D. [1 ]
Williams, S. [2 ]
Fisher, J. [2 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Engn Thermofluids Surfaces & Interfaces iETS, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn iMBE, Leeds LS2 9JT, W Yorkshire, England
关键词
tribology; corrosion; tribocorrosion; hip implants; hip simulator; BIOLOGICAL ENVIRONMENTS; TIME-DEPENDENCE; IMPLANT ALLOYS; WEAR DEBRIS; CORROSION; TRIBOCORROSION; APPRAISAL; ARTHROPLASTY; FRICTION; BIOFILM;
D O I
10.1243/13506501JET762
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Metal-on-metal prostheses have been considered as alternatives to the well-established metal-on-polyethylene implants due to polyethylene wear debris-induced osteolysis. The release of metal ions from metallic components of metal-on-metal joint implants is of great concern to patients and surgeons. Clinical studies have shown that the level of ions in blood and urine samples of patients does not increase linearly with time. Understanding the processes of metallic ion release from the bearing surfaces of metal-on-metal implants is urgent, as more and more younger and active patients demand longer-lasting joint prostheses. In this study, a hip joint simulator with a novel integrated corrosion cell was used. The diameter of the hip joint head was 36 mm. In situ electrochemical measurements were carried out to investigate the interactions between the tribological contacts and corrosion (ion release) processes in simulated biological environments. The role of the tribofilm on the bearing surfaces is discussed. As a conclusion, the complex organometallic tribofilm once formed can protect the bearing surface from further ion release and act to control the level of overall damage from the implant.
引用
收藏
页码:997 / 1006
页数:10
相关论文
共 50 条
  • [41] The Development of a Standard Method for Assessing Wear of Explanted Metal-on-Metal Hip Joints
    Underwood, Richard J.
    Fowell, Mark
    Sayles, Ritchie
    Kurtz, Steven M.
    Cann, Philippa
    METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 130 - 145
  • [42] Wear of CoCrMo alloys used in metal-on-metal hip joints: A tribocorrosion appraisal
    Mischler, Stefano
    Igual Munoz, Anna
    WEAR, 2013, 297 (1-2) : 1081 - 1094
  • [43] Metal-on-metal total hip replacement - What does the literature say?
    Dumbleton, JH
    Manley, MT
    JOURNAL OF ARTHROPLASTY, 2005, 20 (02): : 174 - 188
  • [44] Metal-on-metal hip arthroplasty does equally well in osteonecrosis and osteoarthritis
    Dastane, Manish R.
    Long, William T.
    Wan, Zhinian
    Chao, Lisa
    Dorr, Lawrence D.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (05) : 1148 - 1153
  • [45] The absence of a metal-on-metal bearing does not preclude the formation of a destructive pseudotumor in the hip-a case report
    van Erve, R. H. G. P.
    ACTA ORTHOPAEDICA, 2013, 84 (06) : 598 - 598
  • [46] The absence of a metal-on-metal bearing does not preclude the formation of a destructive pseudotumor in the hip-a case report
    Bisseling, Pepijn
    Tan, Timothy
    Lu, Zhen
    Campbell, Pat A.
    Susante, Job L. C.
    ACTA ORTHOPAEDICA, 2013, 84 (04) : 437 - 441
  • [47] Ion production and excretion in a patient with a metal-on-metal bearing hip prosthesis
    Bitsch, Rudi G.
    Zamorano, Michelle
    Loidolt, Travis
    Heisel, Christian
    Jacobs, Joshua J.
    Schmalzried, Thomas P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12): : 2758 - 2763
  • [48] MODULAR IMPLANT DESIGN AFFECTS METAL ION RELEASE FOLLOWING METAL-ON-METAL HIP ARTHROPLASTY: A RETROSPECTIVE STUDY ON 75 CASES
    La Barbera, L.
    D'Apolito, R.
    Peretti, G. M.
    Piergiovanni, M.
    Banfi, G.
    Zagra, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (02): : 79 - 88
  • [49] Metal release from hip prostheses: biological monitoring of cobalt and chromium in patients with metal-on-metal hip arthroplasty
    Torra, Merce
    Sandalinas, Silvia
    Martin, Mayte
    Nogue, Santiago
    TRACE ELEMENTS AND ELECTROLYTES, 2017, 34 (01) : 1 - 4
  • [50] Concordance between laboratories in metal ion testing in patients with metal-on-metal hip implants
    Saini, Raghav
    Railton, Pam
    Boyd, Jessica
    Sadrzadeh, Hossein
    Powell, James N.
    CANADIAN JOURNAL OF SURGERY, 2019, 62 (01) : 9 - 13