Relationship between inferior vena cava diameter ratio and central venous pressure

被引:8
|
作者
Zhang, Qing [1 ]
Wang, Xiaoting [1 ]
Su, Longxiang [1 ]
Zhang, Hongmin [1 ]
Chai, Wenzhao [1 ]
Chao, Yangong [2 ]
He, Wei [3 ]
Liu, Dawei [1 ]
机构
[1] Chinese Acad Med Sci, Dept Crit Care Med, Peking Union Med Coll Hosp, Peking Union Med Coll, Beijing 100730, Peoples R China
[2] Tsinghua Univ, Hua Xin Hosp, Dept Crit Care Med, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Tongren Hosp, Dept Crit Care Med, Beijing, Peoples R China
关键词
central venous pressure; cross-section; diameter; inferior vena cava; ultrasonography; FLUID RESPONSIVENESS; SHOCK; FLAT;
D O I
10.1002/jcu.22586
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose: To explore the relationship between the shape of the inferior vena cava (IVC) lumen and central venous pressure (CVP). Methods: In 60 patients undergoing mechanical ventilation and CVP monitoring in the Intensive Care Unit of Peking Union Medical College Hospital from July to October 2016, we measured with B-mode ultrasonography the transverse maximum (MXD) and minimum diameter (MID) of the IVC at end expiration, and calculated the diameter ratio (DR) as MXD/MID. Patients were divided into three groups according to CVP: low (CVP < 8 mm Hg), intermediate (8 mm Hg <= CVP <= 10 mm Hg), and high (CVP > 10 mm Hg). Results: MXD was 2.32 +/- 0.41 cm, MID was 1.41 +/- 0.40 cm, and DR was 1.76 +/- 0.49. CVP was 9.27 +/- 2.99 mm Hg. DR correlated with CVP (r = -0.527, P < .001). The low-CVP group had greater dispersion of DR values, with a large variety in IVC shape (elliptical, irregular, teardrop-shaped, partially collapsed...). The area under the ROC curve for predicting CVP with DR, with a CVP threshold of 8 mm Hg was 0.835 (95% CI, 0.726-0.945; P<.05). With a DR cutoff value of 1.76, sensitivity was 0.765 and specificity was 0.781. Conclusions: DR above 1.7 is predictive of CVP < 8 mm Hg.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 50 条
  • [31] Respiratory variation in inferior vena cava diameter: surrogate of central venous pressure or parameter of fluid responsiveness? Let the physiology reply
    Laurent Bodson
    Antoine Vieillard-Baron
    Critical Care, 16
  • [32] Is there a relationship between the diameter of the inferior vena cava and hemodynamic parameters in critically ill patients?
    Aydin, S. A.
    Ozdemir, F.
    Taskin, G.
    Ocakoglu, G.
    Yildirim, H.
    Koksal, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2015, 18 (06) : 810 - 813
  • [33] Correlation between ultrasound-measured inferior vena cava diameter and peripherally inserted central catheter measured central venous pressure in low birth weight infants
    Li, Guang-Hong
    Du, Xiao-Qun
    Sun, Dong-Sheng
    Huang, Hui-Yi
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2025, 17 (03): : 2266 - 2275
  • [34] EFFECT OF AIRWAY PRESSURE ON INFERIOR VENA-CAVA PRESSURE AS A MEASURE OF CENTRAL VENOUS-PRESSURE IN CHILDREN
    REDA, Z
    HOURI, S
    DAVIS, AL
    BAUM, VC
    JOURNAL OF PEDIATRICS, 1995, 126 (06): : 961 - 965
  • [35] ACCURACY OF CENTRAL VENOUS-PRESSURE MEASUREMENTS IN THE INFERIOR VENA-CAVA IN THE VENTILATED CHILD
    MURDOCH, IA
    ROSENTHAL, E
    HUGGON, IC
    COUTINHO, W
    QURESHI, S
    ACTA PAEDIATRICA, 1994, 83 (05) : 512 - 514
  • [36] Ultrasonographic Inferior Vena Cava Indices Correlate with Central Venous Pressure in Mechanically Ventilated Children
    Hooper, Elisabeth
    Angst, Denise
    Neuberger, Stephen
    Tsifansky, Michael
    CHEST, 2013, 144 (04)
  • [37] DOES A SIMPLE BEDSIDE SONOGRAPHIC MEASUREMENT OF THE INFERIOR VENA CAVA CORRELATE TO CENTRAL VENOUS PRESSURE?
    De Lorenzo, Robert A.
    Morris, Michael J.
    Williams, Justin B.
    Haley, Timothy F.
    Straight, Timothy M.
    Holbrook-Emmons, Victoria L.
    Medina, Juanita S.
    JOURNAL OF EMERGENCY MEDICINE, 2012, 42 (04): : 429 - 436
  • [38] ACCURACY OF CENTRAL VENOUS-PRESSURE MEASUREMENT FROM THE ABDOMINAL INFERIOR VENA-CAVA
    LLOYD, TR
    DONNERSTEIN, RL
    BERG, RA
    PEDIATRICS, 1992, 89 (03) : 506 - 508
  • [39] The reliability of the central venous pressure measured via catheter inserted in the abdominal vena cava inferior
    M Cengiz
    L Dosemeci
    M Yilmaz
    F Purnek Akin
    A Ramazanoglu
    Critical Care, 9 (Suppl 1):
  • [40] INFERIOR VENA CAVA PRESSURE
    MULLANE, JF
    GLIEDMAN, ML
    GASTROENTEROLOGY, 1967, 52 (01) : 139 - &