Dynamic radial projection MRI of inhaled hyperpolarized 3He gas

被引:86
|
作者
Wild, JM
Paley, MNJ
Kasuboski, L
Swift, A
Fichele, S
Woodhouse, N
Griffiths, PD
van Beek, EJR
机构
[1] Univ Sheffield, Unit Acad Radiol, Sheffield, S Yorkshire, England
[2] Philips Med Syst, Cleveland, OH USA
关键词
radial projection; (3)helium; hyperpolarized; ventilation; lungs;
D O I
10.1002/mrm.10477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A radial projection sliding-window sequence has been developed for imaging the rapid flow of He-3 gas in human lungs. The short echo time (TE) of the radial sequence lends itself to fast repetition times, and thus allows a rapid update in the image when it is reconstructed with a sliding Window. Oversampling in the radial direction combined with angular undersampling can further reduce the time needed to acquire a complete image data set, without significantly compromising spatial resolution. Controlled flow phantom experiments using hyperpolarized He-3 gas exemplify the temporal resolution of the method. In vivo studies on three healthy volunteers, one patient with chronic obstructive pulmonary disease (COPD), and one patient with hemiparalysis of the right diaphragm demonstrate that it is possible to accurately resolve the passage of gas down the trachea and bronchi and into the peripheral lung. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:991 / 997
页数:7
相关论文
共 50 条
  • [41] Reproducibility of ventilation patterns observed using hyperpolarized 3He MRI in normal volunteers
    MacFall, JR
    Charles, HC
    Ravin, CE
    RADIOLOGY, 1998, 206 (02) : 575 - 576
  • [42] Detection of simulated pulmonary embolism in a porcine model using hyperpolarized 3He MRI
    Jalali, A
    Ishii, M
    Edvinsson, JM
    Guan, L
    Itkin, M
    Lipson, DA
    Baumgardner, JE
    Rizi, RR
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 291 - 298
  • [43] Hyperpolarized 3He and 129Xe MRI: Differences in Asthma Before Bronchodilation
    Svenningsen, Sarah
    Kirby, Miranda
    Starr, Danielle
    Leary, Del
    Wheatley, Andrew
    Maksym, Geoffrey N.
    McCormack, David G.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1521 - 1530
  • [44] Using Hyperpolarized 3He MRI to Evaluate Treatment Efficacy in Cystic Fibrosis Patients
    Sun, Yanping
    O'Sullivan, Brian P.
    Roche, John P.
    Walvick, Ronn
    Reno, Austin
    Baker, Dawn
    Mansour, Joey K.
    Albert, Mitchell S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (05) : 1206 - 1211
  • [45] Dynamic MRI of Respiration with a Compact Bolus of Hyperpolarized He-3
    O'Halloran, R. L.
    Holmes, J. H.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [46] 3D airway segmentation via hyperpolarized 3He gas MRI by using scale-based fuzzy connectedness
    Wang, BQ
    Saha, PK
    Udupa, JK
    Ferrante, MA
    Baumgardner, J
    Roberts, DA
    Rizi, RR
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (1-2) : 77 - 86
  • [47] Magnetic resonance imaging at low magnetic field using hyperpolarized 3He gas
    Suchanek, M
    Cieslar, K
    Palasz, T
    Suchanek, K
    Dohnalik, T
    Olejniczak, Z
    ACTA PHYSICA POLONICA A, 2005, 107 (03) : 491 - 506
  • [48] Gas cells for 3He hyperpolarized via spin-exchange optical pumping
    W. Kim
    S. S. Stepanyan
    A. Kim
    J. A. Tan
    S. Woo
    Journal of the Korean Physical Society, 2016, 68 : 183 - 189
  • [49] Susceptibility Effects in Hyperpolarized 3He Lung MRI at 1.5T and 3T
    Deppe, Martin H.
    Parra-Robles, Juan
    Ajraoui, Salma
    Parnell, Steven R.
    Clemence, Matthew
    Schulte, Rolf F.
    Wild, Jim M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (02) : 418 - 423
  • [50] Nonlinear NMR dynamics in hyperpolarized liquid 3He
    Baudin, Emmanuel
    Hayden, Michael E.
    Tastevin, Genevieve
    Nacher, Pierre-Jean
    COMPTES RENDUS CHIMIE, 2008, 11 (4-5) : 560 - 567