Unexpected foreign body in the bladder of a spinal cord injured patient: A case report

被引:0
|
作者
Mengi, Alper [1 ]
Erhan, Belgin [1 ]
Kara, Belgin [1 ]
Yalcinkaya, Ebru Yilmaz [1 ]
机构
[1] Gaziosmanpasa Taksim Training & Res Hosp, Dept Phys Med & Rehabil, Istanbul, Turkey
来源
JOURNAL OF SPINAL CORD MEDICINE | 2019年 / 42卷 / 06期
关键词
Bladder management; Clean intermittent catheterization; Foreign body; Neurogenic bladder; Spinal cord injury; INTERMITTENT SELF-CATHETERIZATION; HAIR NIDUS; RISK;
D O I
10.1080/10790268.2018.1557862
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Context: Bladder dysfunction is common in patients with spinal cord injuries. Clean intermittent catheterization is a preferred method of neurogenic bladder management among spinal cord injured patients. Some complications may occur due to the use of clean intermittent catheterization. Findings: In this report, we presented a case with an unexpected foreign body detected in the bladder of a patient who used to perform clean intermittent catheterization for her neurogenic bladder management, to our knowledge, which has not been reported in the literature so far. Conclusion/Clinical Relevance: In this case report, we want to emphasis the importance of different kind of foreign bodies remaining in the bladder during clean intermittent catheterization.
引用
收藏
页码:813 / 815
页数:3
相关论文