Evaluation of low-contrast detectability for iterative reconstruction in pediatric abdominal computed tomography: a phantom study

被引:4
|
作者
Rubert, Nicholas [1 ]
Southard, Richard [1 ,2 ]
Hamman, Susan M. [3 ]
Robison, Ryan [1 ,4 ]
机构
[1] Phoenix Childrens Hosp, Dept Radiol, 1919 E Thomas Rd, Phoenix, AZ 85016 USA
[2] Univ Arizona, Coll Med, Phoenix, AZ USA
[3] Univ Michigan Hlth Syst, Dept Radiol, CS Mott Childrens Hosp, Sect Pediat Radiol, Ann Arbor, MI USA
[4] Arizona State Univ, Coll Nursing & Hlth Innovat, Phoenix, AZ USA
关键词
Children; Computed tomography; Dose reduction; Iterative reconstruction; Low-contrast detectability; Phantom; TASK-BASED PERFORMANCE; DOSE REDUCTION; IMAGE QUALITY; CT; ALGORITHM; CAMPAIGN;
D O I
10.1007/s00247-019-04561-8
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Iterative reconstruction is offered by all vendors to achieve similar or better CT image quality at lower doses than images reconstructed with filtered back-projection. Objective The purpose of this study was to investigate the dose-reduction potential for pediatric abdominal CT imaging when using either a commercially available hybrid or a commercially available model-based iterative reconstruction algorithm from a single manufacturer. Materials and methods A phantom containing four low-contrast inserts and a uniform background with total attenuation equivalent to the abdomen of an average 8-year-old child was imaged on a CT scanner (IQon; Philips Healthcare, Cleveland, OH). We reconstructed images using both hybrid iterative reconstruction (iDose(4)) and model-based iterative reconstruction (Iterative Model Reconstruction). The four low-contrast inserts had circular cross-section with diameters of 3 mm, 5 mm, 7 mm and 10 mm and contrasts of 14 Hounsfield units (HU), 7 HU, 5 HU and 3 HU, respectively. Helical scans with identical kilovoltage (kV), pitch, rotation time, and collimation were repeated on the phantom at volume CT dose index (CTDIvol) of 2.0 milligrays (mGy), 3.0 mGy, 4.5 mGy and 6.0 mGy. We measured the contrast-to-noise ratio (CNR) in each rod across scans. Additionally, we collected sub-images containing each rod and sub-images containing the background and used them in two-alternative forced choice observer experiments with four observers (two radiologists and two physicists). We calculated the dose-reduction potential of both iterative reconstruction algorithms relative to a scan performed at 6 mGy and reconstructed with filtered back-projection. Results We calculated dose-reduction potential by either matching average equal observer performance in the two-alternative forced choice experiments or matching CNR. When matching CNR, the dose-reduction potential was 34% to 45% for hybrid iterative reconstruction and 89% to 95% for model-based iterative reconstruction. When matching average observer performance, the dose-reduction potential was 9% to 30% for hybrid iterative reconstruction and 57% to 74% for model-based iterative reconstruction. The range in dose-reduction potential depended on the rod size and contrast level. Conclusion Observer performance in this phantom study indicates that the dose-reduction potential indicated by an observer study is less than that of CNR; extrapolating the results to clinical studies suggests that the dose-reduction potential would also be less.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 50 条
  • [31] Comparison of the low-contrast detectability of two ultrasound systems using a grayscale phantom
    Lorentsson, Robert
    Hosseini, Nasser
    Johansson, Jan-Olof
    Rosenberg, Wiebke
    Stenborg, Benny
    Mansson, Lars Gunnar
    Bath, Magnus
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 366 - 378
  • [32] A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography
    Mishra, Saurav
    Mishra, Sandeep
    Regmi, Sabina
    Gupta, Vivek
    NEURORADIOLOGY JOURNAL, 2024, 37 (02): : 221 - 228
  • [33] New low-contrast resolution phantoms for computed tomography
    Inst. für Medizinische Physik, Universität Erlangen, Krankenhausstraße 12, D-91054 Erlangen, Germany
    Med. Phys., 2 (296-302):
  • [34] New low-contrast resolution phantoms for computed tomography
    Suess, C
    Kalender, WA
    Coman, JM
    MEDICAL PHYSICS, 1999, 26 (02) : 296 - 302
  • [35] Novel materials for low-contrast phantoms for computed tomography
    Allert, Keana D.
    Vangala, Sravanthi
    DiBianca, Frank A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (01) : 9 - 18
  • [36] Evaluation of subjective assessment of the low-contrast visibility in constancy control of computed tomography
    Thilander-Klang, Anne
    Ledenius, Kerstin
    Hansson, Jonny
    Sund, Patrik
    Bath, Magnus
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 449 - 454
  • [37] Effect of pitch, collimation and reconstruction interval on low contrast detectability in spiral computed tomography
    Shumaker, DJ
    McNitt-Gray, MF
    Kimme-Smith, C
    Farahani, K
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 603 - 614
  • [38] Dose and blending fraction quantification for adaptive statistical iterative reconstruction based on low-contrast detectability in abdomen CT
    Zhou, Yifang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 128 - 135
  • [39] Evaluation of Image Quality for 7 Iterative Reconstruction Algorithms in Chest Computed Tomography Imaging: A Phantom Study
    Jensen, Kristin
    Hagemo, Guro
    Tingberg, Anders
    Steinfeldt-Reisse, Claudius
    Mynarek, Georg Karl
    Rivero, Rodriguez Jezabel
    Fosse, Erik
    Martinsen, Anne Catrine
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (05) : 673 - 680
  • [40] Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study
    den Harder, Annemarie M.
    Sucha, Dominika
    van Doormaal, Pieter J.
    Budde, Ricardo P. J.
    de Jong, Pim A.
    Schilham, Arnold M. R.
    Breur, Johannes M. P. J.
    Leiner, Tim
    PLOS ONE, 2017, 12 (04):