The reliability of humerothoracic angles during arm elevation depends on the representation of rotations

被引:9
|
作者
Lopez-Pascual, Juan [1 ]
Liliana Caceres, Magda [1 ]
De Rosario, Helios [1 ,2 ]
Page, Alvaro [1 ,2 ]
机构
[1] Univ Politecn Valencia, Inst Biomecan Valencia, E-46022 Valencia, Spain
[2] CIBER Bioingn Biomat & Nanomed, Grp Tecnol Sanitaria IBV, Valencia, Spain
关键词
Reliability; Shoulder kinematics; Rotation sequence; Human motion analysis; Minimal clinically important difference; SHOULDER KINEMATICS; SYSTEMS;
D O I
10.1016/j.jbiomech.2015.12.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The reliability of joint rotation measurements is an issue of major interest, especially in clinical applications. The effect of instrumental errors and soft tissue artifacts on the variability of human motion measures is well known, but the influence of the representation of joint motion has not yet been studied. The aim of the study was to compare the within-subject reliability of three rotation formalisms for the calculation of the shoulder elevation joint angles. Five repetitions of humeral elevation in the scapular plane of 27 healthy subjects were recorded using a stereophotogrammetry system. The humerothoracic joint angles were calculated using the YX'Y '' and XZ'Y '' Euler angle sequences and the attitude vector. A within-subject repeatability study was performed for the three representations. ICC, SEM and CV were the indices used to estimate the error in the calculation of the angle amplitudes and the angular waveforms with each method. Excellent results were obtained in all representations for the main angle (elevation), but there were remarkable differences for axial rotation and plane of elevation. The YX'Y '' sequence generally had the poorest reliability in the secondary angles. The XZ'Y' sequence proved to be the most reliable representation of axial rotation, whereas the attitude vector had the highest reliability in the plane of elevation. These results highlight the importance of selecting the method used to describe the joint motion when within-subjects reliability is an important issue of the experiment. This may be of particular importance when the secondary angles of motions are being studied. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 50 条
  • [41] Differential activation of scapular muscles, during arm elevation, with and without trigger points
    Bohlooli, N.
    Ahmadi, A.
    Maroufi, N.
    Sarrafzadeh, J.
    Jaberzadeh, S.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2016, 20 (01) : 26 - 34
  • [42] Infraspinatus fatigue during resisted arm elevation with isometric contraction: an electromyographic study
    Kai, Yoshihiro
    Gotoh, Masafumi
    Nagata, Kensei
    Shiba, Naoto
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1104 - 1109
  • [43] Electromyographic activities of the biceps during arm elevation in shoulders with rotator cuff tears
    Kido, T
    Itoi, E
    Konno, N
    Sano, A
    Urayama, M
    Sato, K
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (06): : 575 - 579
  • [44] Three-dimensional scapulothoracic motion during active and passive arm elevation
    Ebaugh, DD
    McClure, PW
    Karduna, AR
    CLINICAL BIOMECHANICS, 2005, 20 (07) : 700 - 709
  • [45] RESPIRATORY RESPONSE AND VENTILATORY MUSCLE RECRUITMENT DURING ARM ELEVATION IN NORMAL SUBJECTS
    COUSER, JI
    MARTINEZ, FJ
    CELLI, BR
    RASSULO, J
    CHEST, 1992, 101 (02) : 336 - 340
  • [46] Biomechanical analysis of the maxillary sinus floor membrane during internal sinus floor elevation with implants at different angles of the maxillary sinus angles
    Yinxin Deng
    Ruihong Ma
    Yilin He
    Shujia Yu
    Shiyu Cao
    Kang Gao
    Yiping Dou
    Pan Ma
    International Journal of Implant Dentistry, 10
  • [47] Biomechanical analysis of the maxillary sinus floor membrane during internal sinus floor elevation with implants at different angles of the maxillary sinus angles
    Deng, Yinxin
    Ma, Ruihong
    He, Yilin
    Yu, Shujia
    Cao, Shiyu
    Gao, Kang
    Dou, Yiping
    Ma, Pan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [48] Representation of distribution system reliability during network restoration and repair
    McDonald, J. D. F.
    Pal, B. C.
    Lang, P. D.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 4151 - +
  • [49] Observer performance in estimating upper arm elevation angles under ideal viewing conditions when assisted by posture matching software
    Jackson, Jennie A.
    Mathiassen, Svend Erik
    Liv, Per
    APPLIED ERGONOMICS, 2016, 55 : 208 - 215
  • [50] Planar covariation of limb elevation angles during bipedal locomotion in common quails (Coturnix coturnix)
    Ogihara, Naomichi
    Oku, Takaaki
    Andrada, Emanuel
    Blickhan, Reinhard
    Nyakatura, John A.
    Fischer, Martin S.
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2014, 217 (22): : 3968 - 3973