X-ray Micro-CT: How Soil Pore Space Description Can Be Altered by Image Processing

被引:11
|
作者
Smet, Sarah [1 ]
Plougonven, Erwan [2 ]
Leonard, Angelique [2 ]
Degre, Aurore [1 ]
Beckers, Eleonore [1 ]
机构
[1] Univ Liege, Gembloux Agrobio Tech, BIOSE, Soil Water Plant Exchanges, 2 Passage Deportes, B-5030 Gembloux, Belgium
[2] Univ Liege, Prod Environm Proc PEPs, Chem Engn, B-4000 Liege, Belgium
关键词
COMPUTED-TOMOGRAPHY; THRESHOLDING METHOD; MICROTOMOGRAPHY; SEGMENTATION; TILLAGE; MODEL; QUANTIFICATION; TRANSPORT; POROSITY; QUALITY;
D O I
10.2136/vzj2016.06.0049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A physically accurate conversion of the X-ray tomographic reconstructions of soil into pore networks requires a certain number of image processing steps. An important and much discussed issue in this field relates to segmentation, or distinguishing the pores from the solid, but pre- and post-segmentation noise reduction also affects the pore networks that are extracted. We used 15 two-dimensional simulated grayscale images to quantify the performance of three segmentation algorithms. These simulated images made ground-truth information available and a quantitative study feasible. The analyses were based on five performance indicators: misclassification error, non-region uniformity, and relative errors in porosity, conductance, and pore shape. Three levels of pre-segmentation noise reduction were tested, as well as two levels of post-segmentation noise reduction. Three segmentation methods were tested (two global and one local). For the local method, the threshold intervals were selected from two concepts: one based on the histogram shape and the other on the image visible-porosity value. The results indicate that pre-segmentation noise reduction significantly (p < 0.05) improves segmentation quality, but post-segmentation noise reduction is detrimental. The results also suggest that global and local methods perform in a similar way when noise reduction is applied. The local method, however, depends on the choice of threshold interval.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Optimal X-ray micro-CT image based methods for porosity and permeability quantification in heterogeneous sandstones
    Callow, Ben
    Falcon-Suarez, Ismael
    Marin-Moreno, Hector
    Bull, Jonathan M.
    Ahmed, Sharif
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2020, 223 (02) : 1210 - 1229
  • [32] Morphological Functions with Parallel Sets for the Pore Space of X-ray CT Images of Soil Columns
    F. San José Martínez
    F. J. Muñoz Ortega
    F. J. Caniego Monreal
    F. Peregrina
    Pure and Applied Geophysics, 2016, 173 : 995 - 1009
  • [33] Morphological Functions with Parallel Sets for the Pore Space of X-ray CT Images of Soil Columns
    San Jose Martinez, F.
    Munoz Ortega, F. J.
    Caniego Monreal, F. J.
    Peregrina, F.
    PURE AND APPLIED GEOPHYSICS, 2016, 173 (03) : 995 - 1009
  • [34] Description of a new fossil Pseudogarypus (Pseudoscorpiones: Pseudogarypidae) with the use of X-ray micro-CT to penetrate opaque amber
    Henderickx, Hans
    Cnudde, Veerle
    Masschaele, Bert
    Dierick, Manuel
    Vlassenbroeck, Jelle
    Van Hoorebeke, Luc
    ZOOTAXA, 2006, (1305) : 41 - 50
  • [35] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [36] Data-Constrained Microstructure Characterization with Multispectrum X-Ray Micro-CT
    Mayo, Sheridan C.
    Tulloh, Andrew M.
    Trinchi, Adrian
    Yang, Sam Y. S.
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (03) : 524 - 530
  • [37] A reconstruction of the lophophore of Devonian rhynchonellids (Brachiopoda) by using X-Ray micro-CT
    A. V. Pakhnevich
    Paleontological Journal, 2017, 51 : 143 - 154
  • [38] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [39] X-ray micro-CT measurement of large parts at very low temperature
    Koutecky, T.
    Zikmund, T.
    Glittova, D.
    Palousek, D.
    Zivcak, J.
    Kaiser, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [40] X-ray Micro-CT based characterization of rock cuttings with deep learning
    Olsen, Nils
    Chen, Yifeng
    Turberg, Pascal
    Moreau, Alexandre
    Alahi, Alexandre
    APPLIED COMPUTING AND GEOSCIENCES, 2025, 25