An enhanced Nonenzymatic Electrochemical Glucose Sensor Based on Copper-Palladium Nanoparticles Modified Glassy Carbon Electrodes

被引:37
|
作者
Li, Zhan-Hong [1 ,2 ]
Zhao, Xue-Ling [1 ,2 ]
Jiang, Xin-Cheng [1 ]
Wu, Yi-Hua [1 ,2 ]
Chen, Cheng [1 ,2 ]
Zhu, Zhi-Gang [1 ,2 ]
Marty, Jean-Louis [3 ]
Chen, Qing-Song [4 ]
机构
[1] Shanghai Polytech Univ, Coll Engn, Sch Environm & Mat Engn, Shanghai 201209, Peoples R China
[2] Shanghai Innovat Inst Mat, Shanghai 200444, Peoples R China
[3] Univ Perpignan, BAE Lab, Via Domitia,52 Ave Paul Alduy, F-66860 Perpignan, France
[4] Chinese Acad Sci, Fujian Inst Res Struct Matter, State Key Lab Struct Chem, Fuzhou 350002, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose; nonenzymatic sensor; copper; palladium; synergistic effect; FORMIC-ACID OXIDATION; HYDROGEN-PEROXIDE; ELECTROCATALYTIC REDUCTION; ALKALINE MEDIA; ELECTROOXIDATION; BIOSENSORS; ALLOY; NANOMATERIALS; NANOSHEETS; NANOTUBES;
D O I
10.1002/elan.201800017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel copper-palladium nanoparticles modified glassy carbon electrodes (Cu-Pd/GC) with enhanced nonenzymatic sensing for glucose were facilely prepared by one-step electrodeposition. The structure and composition of the prepared nanoparticles were characterized by XRD, SEM, TEM and EDS, respectively. The electrode modified process was characterized by electrochemical impedance spectroscopy. Cyclic voltammetry and chronoamperometric experiments were used to evaluate the electrocatalytic activities of the electrodes toward glucose. The surface morphology and the electrocatalytic activities of Cu-Pd/GC was compared to Pd and Cu nanoparticles modified glassy carbon electrodes (Pd/GC and Cu/GC), respectively. Thanks to homogeneous distribution of Cu-Pd nanoparticles and the synergistic effect of Cu and Pd atoms, Cu-Pd/GC exhibited the highest sensitivity (298AmM(-1)cm(-2)) and the widest linear amperometric response (0.01mM to 9.6mM, R-2=0.996) toward glucose compared to Pd/GC and Cu/GC. The detection limit of Cu-Pd/GC was 0.32M (S/N=3). In addition, the as-prepared Cu-Pd/GC glucose sensor also exhibited exceptional capabilities of anti-interference, reproducibility and long-term stability. The as-prepared sensor was also evaluated for determination of glucose concentration in human blood serum samples, which exhibited high reliability and accuracy, having great potential in clinical application.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [31] Nonenzymatic Glucose Sensor: Glassy Carbon Electrode Modified with Graphene-Nickel/Nickel Oxide Composite
    Kumary, V. Anitha
    Nancy, T. E. Mary
    Divya, J.
    Sreevalsan, K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 2220 - 2228
  • [32] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Palanisamy, Selvakumar
    Ku, Shuhao
    Chen, Shen-Ming
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1037 - 1042
  • [33] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Selvakumar Palanisamy
    Shuhao Ku
    Shen-Ming Chen
    Microchimica Acta, 2013, 180 : 1037 - 1042
  • [34] Electrochemical Characterization of Modified Glassy Carbon Electrodes for Non-Enzymatic Glucose Sensors
    Mazurkow, Julia Maria
    Kusior, Anna
    Radecka, Marta
    SENSORS, 2021, 21 (23)
  • [35] Electrochemical Glucose Oxidation Using Glassy Carbon Electrodes Modified with Au-Ag Nanoparticles: Influence of Ag Content
    Gabriela Garcia-Morales, Nancy
    Alfonso Garcia-Cerda, Luis
    Alicia Puente-Urbina, Bertha
    Maria Blanco-Jerez, Leonor
    Antano-Lopez, Rene
    Castaneda-Zaldivar, Federico
    JOURNAL OF NANOMATERIALS, 2015, 2015
  • [36] Electrochemical sensor for amino acids based on gold nanoparticles/macroporous carbon composites modified glassy carbon electrode
    Zeng, Lijun
    Wang, Huan
    Bo, Xiangjie
    Guo, Liping
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 687 : 117 - 122
  • [37] An electrochemical capacitor using modified glassy carbon electrodes
    Sullivan, MG
    Bartsch, M
    Kotz, R
    Haas, O
    PROCEEDINGS OF THE SYMPOSIUM ON ELECTROCHEMICAL CAPACITORS II, 1997, 96 (25): : 192 - 201
  • [38] Electrochemical Sensing of Tinidazole on Modified Glassy Carbon Electrodes
    Jos, Theresa
    Jose, Ammu Rosin
    Sivasankaran, Unni
    Kumar, Krishnapillai Girish
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (04) : B94 - B100
  • [39] Electrochemical sensor based on glassy carbon electrode modified with copper vanadate nanobelts for detection of benzoic acid
    Lin, Nan
    Pei, LiZhai
    Wei, Tian
    Liu, HanDing
    Cai, ZhengYu
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (04) : 247 - 252
  • [40] Functionalization of Carbon Nanotubes with Copper for Nonenzymatic Electrochemical Detection of Glucose
    Guo, Chang
    Wang, Lin
    Li, Maoguo
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2014, 6 (06) : 481 - 487