An enhanced Nonenzymatic Electrochemical Glucose Sensor Based on Copper-Palladium Nanoparticles Modified Glassy Carbon Electrodes

被引:37
|
作者
Li, Zhan-Hong [1 ,2 ]
Zhao, Xue-Ling [1 ,2 ]
Jiang, Xin-Cheng [1 ]
Wu, Yi-Hua [1 ,2 ]
Chen, Cheng [1 ,2 ]
Zhu, Zhi-Gang [1 ,2 ]
Marty, Jean-Louis [3 ]
Chen, Qing-Song [4 ]
机构
[1] Shanghai Polytech Univ, Coll Engn, Sch Environm & Mat Engn, Shanghai 201209, Peoples R China
[2] Shanghai Innovat Inst Mat, Shanghai 200444, Peoples R China
[3] Univ Perpignan, BAE Lab, Via Domitia,52 Ave Paul Alduy, F-66860 Perpignan, France
[4] Chinese Acad Sci, Fujian Inst Res Struct Matter, State Key Lab Struct Chem, Fuzhou 350002, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose; nonenzymatic sensor; copper; palladium; synergistic effect; FORMIC-ACID OXIDATION; HYDROGEN-PEROXIDE; ELECTROCATALYTIC REDUCTION; ALKALINE MEDIA; ELECTROOXIDATION; BIOSENSORS; ALLOY; NANOMATERIALS; NANOSHEETS; NANOTUBES;
D O I
10.1002/elan.201800017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel copper-palladium nanoparticles modified glassy carbon electrodes (Cu-Pd/GC) with enhanced nonenzymatic sensing for glucose were facilely prepared by one-step electrodeposition. The structure and composition of the prepared nanoparticles were characterized by XRD, SEM, TEM and EDS, respectively. The electrode modified process was characterized by electrochemical impedance spectroscopy. Cyclic voltammetry and chronoamperometric experiments were used to evaluate the electrocatalytic activities of the electrodes toward glucose. The surface morphology and the electrocatalytic activities of Cu-Pd/GC was compared to Pd and Cu nanoparticles modified glassy carbon electrodes (Pd/GC and Cu/GC), respectively. Thanks to homogeneous distribution of Cu-Pd nanoparticles and the synergistic effect of Cu and Pd atoms, Cu-Pd/GC exhibited the highest sensitivity (298AmM(-1)cm(-2)) and the widest linear amperometric response (0.01mM to 9.6mM, R-2=0.996) toward glucose compared to Pd/GC and Cu/GC. The detection limit of Cu-Pd/GC was 0.32M (S/N=3). In addition, the as-prepared Cu-Pd/GC glucose sensor also exhibited exceptional capabilities of anti-interference, reproducibility and long-term stability. The as-prepared sensor was also evaluated for determination of glucose concentration in human blood serum samples, which exhibited high reliability and accuracy, having great potential in clinical application.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [1] Electrochemical Sensor Based on Glassy Carbon Electrode Modified by Palladium Doped ZnO Nanostructures for Glucose Detection
    Yuan, Qingshan
    Zhang, Zunju
    Li, Lei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (06): : 5245 - 5254
  • [2] Nonenzymatic Electrochemical Glucose Sensor Based on Pt Nanoparticles/Mesoporous Carbon Matrix
    Su, Chang
    Zhang, Cheng
    Lu, Guoqiang
    Ma, Chunan
    ELECTROANALYSIS, 2010, 22 (16) : 1901 - 1905
  • [3] Development of an electrochemical sensor for the determination of glycerol based on glassy carbon electrodes modified with a copper oxide nanoparticles/multiwalled carbon nanotubes/pectin composite
    Javier Arevalo, Fernando
    Osuna-Sanchez, Yolanda
    Sandoval-Cortes, Jose
    Di Tocco, Aylen
    Marcelo Granero, Adrian
    Noel Robledo, Sebastian
    Alicia Zon, Maria
    Roberto Vettorazzi, Nelio
    Luis Martinez, Jose
    Patricia Segura, Elda
    Ilina, Anna
    Fernandez, Hector
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 949 - 957
  • [4] Nonenzymatic sensing of glucose using a glassy carbon electrode modified with halloysite nanotubes heavily loaded with palladium nanoparticles
    Wu, Qian
    Sheng, Qinglin
    Zheng, Jianbin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 762 : 51 - 58
  • [5] Nonenzymatic glucose sensor based on a glassy carbon electrode modified with chains of platinum hollow nanoparticles and porous gold nanoparticles in a chitosan membrane
    Li, Jingjing
    Yuan, Ruo
    Chai, Yaqin
    Che, Xin
    Li, Wenjuan
    Zhong, Xia
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 163 - 169
  • [6] Nonenzymatic glucose sensor based on a glassy carbon electrode modified with chains of platinum hollow nanoparticles and porous gold nanoparticles in a chitosan membrane
    Jingjing Li
    Ruo Yuan
    Yaqin Chai
    Xin Che
    Wenjuan Li
    Xia Zhong
    Microchimica Acta, 2011, 172 : 163 - 169
  • [7] Electrochemical sensor for amino acids and glucose based on glassy carbon electrodes modified with multi-walled carbon nanotubes and copper microparticles dispersed in polyethylenimine
    Gutierrez, Fabiana A.
    Rubianes, Maria D.
    Rivas, Gustavo A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 765 : 16 - 21
  • [8] Nonenzymatic glucose sensor based on disposable pencil graphite electrode modified by copper nanoparticles
    Pourbeyram, Sima
    Mehdizadeh, Khadijeh
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2016, 24 (04) : 894 - 902
  • [9] Electrodeposition of Nickel Nanoparticles Modified Glassy Carbon Electrode for Nonenzymatic Glucose Biosensing
    Guo, Honghui
    Huang, Zhengjun
    Zheng, Yanjie
    Weng, Shaohuang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (12): : 10703 - 10712
  • [10] Nonenzymatic sensor for glucose based on a glassy carbon electrode modified with Ni(OH)2 nanoparticles grown on a film of molybdenum sulfide
    Ji, Shanshan
    Yang, Zhe
    Zhang, Chao
    Miao, Yue-E
    Tjiu, Weng Weei
    Pan, Jisheng
    Liu, Tianxi
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1127 - 1134