Use of adhesives to increase the load-bearing capacity of slip-resistant connections.

被引:7
|
作者
Glienke, Ralf [1 ]
Ebert, Andreas [1 ]
Denkert, Christian [1 ]
Henkel, Knuth-Michael [1 ]
Kalich, Jan [2 ]
Fuessel, Uwe [2 ]
机构
[1] Fraunhofer Einrichtung Grossstrukturen Prod Tech, Albert Einstein Str 30, D-18059 Rostock, Germany
[2] Tech Univ Dresden, Prof Fugetech & Montage, George Bahr Str 3c, D-01069 Dresden, Germany
关键词
TOWERS; STEEL;
D O I
10.1002/stab.201710493
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Slip-resistant connections are preferred for steel constructions if subjected to fatigue loads and/or load reversals, no slip in the connection is permitted and joining on construction site is necessary. These connections are pre-pared with a high manufacturing effort due to the intensive preparation of the faying surfaces, or the contact area between the steel plies and it must receive special consideration in design and coating application. The typical corrosion protection for steel structures is still the hot-dip galvanizing. The follow-up work of the faying surfaces for a use in slip-resistant connections is related to a high effort and guarantees no high slip factors. Furthermore the slip factor may deviate more or less high with the properties of the zinc layer. Against this background, investigations have been carried out in a recently concluded research project which show an increase in the load bearing capacity of slip-resistant connections by the combined use of adhesive. In the case of the process combination, which is also referred and named as a preloaded hybrid connection, the applied preload of the highstrength bolts is responsible for the considerable increase in load bearing capacity compared to the elementary joining processes adhesive bonding or just slip-resistant connections. If the two methods are carefully combined, the individual load bearing -capacities can approximately add up.
引用
收藏
页码:811 / 830
页数:20
相关论文
共 50 条
  • [31] LOAD-BEARING CAPACITY OF CAPTEK CROWNS AND BRIDGES
    JUNTAVEE, N
    GORDANO, R
    NATHANSON, D
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 471 - 471
  • [32] CHARACTERIZATION OF STRUCTURAL ADHESIVES FOR LOAD-BEARING COMPOSITE STRUCTURAL APPLICATIONS
    AHN, KJ
    EOM, YS
    SHIM, YT
    SEFERIS, JC
    COMPOSITE STRUCTURES, 1994, 27 (1-2) : 57 - 64
  • [33] Assessment of the load-bearing capacity of a primary pipeline
    Gubeljak, Nenad
    Tuma, Jelena Vojvodic
    Sustarsic, Borivoj
    Predan, Jozef
    Oblak, Maks
    ENGINEERING FRACTURE MECHANICS, 2007, 74 (06) : 995 - 1005
  • [34] Analysis of the Load-Bearing Capacity of Pebble Aggregates
    Liu, Pan
    Bai, Peiyi
    Liu, Wenju
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [35] STEEL FOR SPRINGS WITH A HIGH LOAD-BEARING CAPACITY
    TSVETOVKA, LG
    SOVIET ENGINEERING RESEARCH, 1983, 3 (10): : 33 - 35
  • [36] Load-bearing capacity of plain concrete walls
    Hegger, J.
    Dressen, T.
    Will, N.
    MAGAZINE OF CONCRETE RESEARCH, 2009, 61 (03) : 173 - 182
  • [37] Load-bearing capacity of tempered structural glass
    Carré, H
    Daudeville, L
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1999, 125 (08): : 914 - 921
  • [38] Load-Bearing Capacity of Deviated CFRP Strips
    Hwash, Mohamed
    Knippers, Jan
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (04)
  • [39] Load-bearing capacity of tempered structural glass
    Carré, Hélène
    Daudeville, L.
    Journal of Engineering Mechanics, 1999, 125 (08): : 914 - 921
  • [40] Calculation method for the axial load-bearing capacity of steel pipe-to-sleeve grouted connections
    Wu, Liwei
    Guo, Xueyuan
    Chen, Haibin
    Liu, Junyang
    Su, Youpo
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 314