Long-term testing of an intracranial pressure monitoring device

被引:16
|
作者
Kroin, JS
McCarthy, RJ
Stylos, L
Miesel, K
Ivankovich, AD
Penn, RD
机构
[1] Rush Med Coll, Dept Neurosurg, Chicago, IL 60612 USA
[2] Rush Med Coll, Dept Anesthesiol, Chicago, IL 60612 USA
[3] Mt Sinai Sch Med, Dept Neurosurg, New York, NY USA
[4] Medtron Inc, Minneapolis, MN USA
关键词
cerebrospinal fluid; intracranial pressure; head injury; hydrocephalus; dog;
D O I
10.3171/jns.2000.93.5.0852
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Long-term monitoring of intracranial pressure (ICP) is limited by the lack of an implantable sensor with low drift. The goal of this study was to demonstrate that a new capacitive transducer system will produce accurate and stable ICP records over extended periods. Methods. Intracranial pressure sensors were implanted into the frontal white matter of four dogs. Tn addition, a fluid-filled catheter was placed in the cisterna magna (CM) to measure cerebrospinal fluid (CSF) pressure. The animals were tested using standard physiological maneuvers such as jugular vein compression, head elevation, and CSF withdrawal from and saline injection into the CM to verify that the ICP sensor precisely matched CSF pressure changes. The mean ICP pressure and CM pressure were compared for months to demonstrate that the transducer system produced minimal drift over time. The change in the ICP sensor record closely duplicated that of the CSF waveform in the CM in response to well-known physiological stimuli. More important, mean ICP pressure remained within 3 mm Hg of CM pressure for months, with a mean difference of less than 0.3 mm Hg, Histological examination of the dog brains revealed only minimal tissue reaction to the presence of the sensor. Conclusions. The authors demonstrate a new implantable solid-state sensor that reliably measures ICP for months, with minimal drift. The clinical application of this sensor and its telemetry is for long-term monitoring of patients with head injury, mass lesions, and hydrocephalus.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 50 条
  • [1] LONG-TERM INTRACRANIAL-PRESSURE MONITORING
    DEJONG, DA
    MAAS, AIR
    DENOUDEN, AH
    DELANGE, SA
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1983, 10 (02) : 89 - 96
  • [2] Technique for very long-term monitoring of intracranial pressure
    Brindley, G.S.
    Polkey, C.E.
    Cooper, J.D.
    Medical and Biological Engineering and Computing, 1983, 21 (04): : 460 - 464
  • [3] NEW DEVICE FOR LONG-TERM INTRACRANIAL-PRESSURE MEASUREMENT
    MEYER, GA
    LYON, WC
    BUSTARD, TS
    CHILDS BRAIN, 1975, 1 (04): : 217 - 227
  • [4] TECHNIQUE FOR VERY LONG-TERM MONITORING OF INTRACRANIAL-PRESSURE
    BRINDLEY, GS
    POLKEY, CE
    COOPER, JD
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (04) : 460 - 464
  • [5] Clinical and radiological findings in long-term intracranial pressure monitoring
    Sebastian Antes
    Christoph A. Tschan
    Gerd Kunze
    Lara Ewert
    Anna Zimmer
    Alexander Halfmann
    Joachim Oertel
    Acta Neurochirurgica, 2014, 156 : 1009 - 1019
  • [6] Clinical and radiological findings in long-term intracranial pressure monitoring
    Antes, Sebastian
    Tschan, Christoph A.
    Kunze, Gerd
    Ewert, Lara
    Zimmer, Anna
    Halfmann, Alexander
    Oertel, Joachim
    ACTA NEUROCHIRURGICA, 2014, 156 (05) : 1009 - 1019
  • [7] A novel method for long-term monitoring of intracranial pressure in rats
    Uldall, Maria
    Juhler, Marianne
    Skjolding, Anders Daehli
    Kruuse, Christina
    Jansen-Olesen, Inger
    Jensen, Rigmor
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 227 : 1 - 9
  • [8] FALSE FONTANELLE AS A PRACTICAL METHOD OF LONG-TERM TESTING OF INTRACRANIAL PRESSURE
    FORREST, DM
    TSINGOGL.S
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1968, S : 17 - &
  • [9] Long-term telemetric intracerebral pressure monitoring as a tool in intracranial hypotension
    Thorbjørn Søren Rønn Jensen
    Harold L. Rekate
    Marianne Juhler
    Acta Neurochirurgica, 2021, 163 : 733 - 737
  • [10] CLINICAL EVALUATION OF LONG-TERM EPIDURAL MONITORING OF INTRACRANIAL-PRESSURE
    GUCER, G
    VIERNSTEIN, LJ
    CHUBBUCK, JG
    WALKER, AE
    SURGICAL NEUROLOGY, 1979, 12 (05): : 373 - 377