Compression-free biplanar radiography of the breast specimen with a specimen device

被引:5
|
作者
Grunert, JH
Wiechmann, U
Gmelin, E
机构
[1] Oststadtkrankenhaus Hannover, Med Hsch Hannover, D-31303 Burgdorf, Germany
[2] Hannover Med Sch, Forschungswerkstatten, Hannover, Germany
关键词
breast cancer; microcalcification; specimen device; specimen radiography;
D O I
10.1055/s-2003-37821
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a device for specimen radiography of impalpable breast lesions with microcalcifications in order to perform compression-free radiography in two planes and to document the original orientation of the specimen on the radiographic film. Materials and Methods: A curved plate with its radius equal to the film-focus-distance enables specimen radiography without compression and with minimizing artifacts induced by beam divergency. Adjustable markers can document the topographic orientation of the specimen on the radiographic film. Results: The presented specimen device for biplanar radiography avoids interfering compression artifacts for both radiologist and pathologist. Documenting the original topographic orientation of the specimen on the film helps to guide the surgeon in cases requiring further resection. Discussion: Biplanar specimen radiography without compression of the specimen measures the distance of microcalcifications to the margin of the resected tissue more accurately and thus provides a better basis for planning any necessary additional resection.
引用
收藏
页码:413 / 417
页数:5
相关论文
共 50 条
  • [31] Comparison of dedicated digital specimen radiography with direct digital specimen mammography images
    JC Morel
    V Milnes
    A Iqbal
    MJ Michell
    Breast Cancer Research, 13
  • [32] FILM MAMMOGRAPHIC TECHNIQUE IN SPECIMEN RADIOGRAPHY
    DCRUZ, CA
    PATEL, RB
    LABORATORY INVESTIGATION, 1983, 48 (01) : A98 - A98
  • [33] DOUBLE CONTRAST SPECIMEN RADIOGRAPHY OF THE GALLBLADDER
    SANDIN, BM
    MALTBY, DE
    WILKINS, RA
    CLINICAL RADIOLOGY, 1987, 38 (05) : 556 - 556
  • [34] Comparison of dedicated digital specimen radiography with direct digital specimen mammography images
    Morel, J. C.
    Milnes, V.
    Iqbal, A.
    Michell, M. J.
    BREAST CANCER RESEARCH, 2011, 13
  • [35] Clinical Evaluation of a Mobile Digital Specimen Radiography System for Intraoperative Specimen Verification
    Wang, Yingbing
    Ebuoma, Lilian
    Saksena, Mansi
    Liu, Bob
    Specht, Michelle
    Rafferty, Elizabeth
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 457 - 462
  • [36] SPECIMEN RADIOGRAPHY OF BONE-TUMORS
    JENSEN, OM
    MADSEN, EH
    ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (2-3): : 119 - 125
  • [37] SPECIMEN RADIOGRAPHY - MANDATORY ADJUNCT TO MAMMOGRAPHY
    BAUERMEISTER, DE
    HALL, MH
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1973, 59 (06) : 782 - 789
  • [38] Investigation of influence of stiffness of the loading device during specimen compression test
    Zaretskij-Feoktistov, G.G.
    Gornyi Zhurnal, 16 (9-10): : 43 - 46
  • [39] Specimen 'sandwich' - orientating the operative specimen in breast surgery
    Dimock, R.
    Pakzad, F.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2017, 99 (02) : 175 - 176
  • [40] DETECTION OF OCCULT CARCINOMA IN APPARENTLY BENIGN BREAST BIOPSY THROUGH SPECIMEN RADIOGRAPHY
    ROSEN, P
    SNYDER, RE
    FOOTE, FW
    WALLACE, T
    CANCER, 1970, 26 (04) : 944 - &