A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy

被引:51
|
作者
Clark, Catharine H. [1 ,2 ,3 ]
Hussein, Mohammad [1 ,4 ]
Tsang, Yatman [3 ,5 ]
Thomas, Russell [2 ]
Wilkinson, Dean [3 ,5 ]
Bass, Graham [2 ]
Snaith, Julia [2 ]
Gouldstone, Clare [2 ]
Bolton, Steve [6 ,7 ]
Nutbrown, Rebecca [2 ]
Venables, Karen [3 ,5 ]
Nisbet, Andrew [1 ,4 ]
机构
[1] Royal Surrey Cty Hosp, Dept Med Phys, Guildford GU2 7XX, Surrey, England
[2] Natl Phys Lab, London, England
[3] Univ Surrey, NCRI Radiotherapy Trials Qual Assurance Grp, Guildford GU2 5XH, Surrey, England
[4] Univ Surrey, Ctr Nucl & Radiat Phys, Guildford GU2 5XH, Surrey, England
[5] Mt Vernon Hosp, Northwood HA6 2RN, Middx, England
[6] Christie Hosp, Manchester, Lancs, England
[7] Inst Phys & Engn Med, York, N Yorkshire, England
关键词
Audit; IMRT; VMAT; Detector arrays; IMRT; METHODOLOGY;
D O I
10.1016/j.radonc.2014.11.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Rotational IMRT (VMAT and Tomotherapy) has now been implemented in many radiotherapy centres. An audit to verify treatment planning system modelling and treatment delivery has been undertaken to ensure accurate clinical implementation. Material and methods: 34 institutions with 43 treatment delivery systems took part in the audit. A virtual phantom planning exercise (3DTPS test) and a clinical trial planning exercise were planned and independently measured in each institution using a phantom and array combination. Point dose differences and global gamma index (gamma) were calculated in regions corresponding to PTVs and OARs. Results: Point dose differences gave a mean (+/- sd) of 0.1 +/- 2.6% and 0.2 +/- 2.0% for the 3DTPS test and clinical trial plans, respectively. 34/43 planning and delivery combinations achieved all measured planes with >95% pixels passing gamma < 1 at 3%/3 mm and rose to 42/43 for clinical trial plans. A statistically significant difference in gamma pass rates (p < 0.01) was seen between planning systems where rotational IMRT modelling had been designed for the manufacturer's own treatment delivery system and those designed independently of rotational IMRT delivery. Conclusions: A dosimetry audit of rotational radiotherapy has shown that TPS modelling and delivery for rotational IMRT can achieve high accuracy of plan delivery. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [21] Intensity-modulated radiotherapy for cancers in childhood
    Leseur, J.
    Carrie, C.
    Prise, E. Le
    Bernier, V.
    Beneyton, V.
    Mahe, M. A.
    Supiot, S.
    CANCER RADIOTHERAPIE, 2009, 13 (6-7): : 536 - 542
  • [22] Intensity-Modulated Radiotherapy for Pancreatic Adenocarcinoma
    Abelson, Jonathan A.
    Murphy, James D.
    Minn, Ann Yuriko
    Chung, Melody
    Fisher, George A.
    Ford, James M.
    Kunz, Pamela
    Norton, Jeffrey A.
    Visser, Brendan C.
    Poultsides, George A.
    Koong, Albert C.
    Chang, Daniel T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (04): : E595 - E601
  • [23] OPTIMIZING THE PLANNING OF INTENSITY-MODULATED RADIOTHERAPY
    WEBB, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (12): : 2229 - 2246
  • [24] Intensity-modulated radiotherapy for sinonasal teratocarcinosarcoma
    Gang Peng
    Yang Ke
    Tao Wang
    Yiming Feng
    Yuehua Li
    Gang Wu
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2011, 31 : 857 - 860
  • [25] Exploration of tradeoffs in intensity-modulated radiotherapy
    Craft, D
    Halabi, T
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24): : 5857 - 5868
  • [26] Intensity-modulated Radiotherapy for Sinonasal Teratocarcinosarcoma
    彭纲
    柯杨
    王涛
    冯一鸣
    李跃华
    伍钢
    Current Medical Science, 2011, (06) : 857 - 860
  • [27] Intensity-modulated radiotherapy for sinonasal teratocarcinosarcoma
    Peng, Gang
    Ke, Yang
    Wang, Tao
    Feng, Yiming
    Li, Yuehua
    Wu, Gang
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2011, 31 (06) : 857 - 860
  • [28] Practical experience with intensity-modulated radiotherapy
    James, HV
    Scrase, CD
    Poynter, AJ
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (913): : 3 - 14
  • [29] Nomogram for radiation-induced lymphopenia in patients receiving intensity-modulated radiotherapy based-chemoradiation therapy for newly diagnosed glioblastoma: A multi-institutional study
    Kim, Nalee
    Lee, Joongyo
    Shin, Hyunju
    Shin, Jungwook
    Nam, Do-Hyun
    Lee, Jung-Il
    Seol, Ho Jun
    Kong, Doo-Sik
    Choi, Jung Won
    Chong, Kyuha
    Lee, Won Jae
    Chang, Jong Hee
    Kang, Seok-Gu
    Moon, Ju Hyung
    Cho, Jaeho
    Lim, Do Hoon
    Yoon, Hong in
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 47
  • [30] Definitive-intent intensity-modulated radiation therapy for treatment of canine prostatic carcinoma: A multi-institutional retrospective study
    Walz, Jillian Z.
    Desai, Noopur
    Van Asselt, Nathaniel
    Poirier, Valerie J.
    Hansen, Katherine
    Selmic, Laura
    VETERINARY AND COMPARATIVE ONCOLOGY, 2020, 18 (03) : 381 - 388