A Self-calibration Method of Lander Manipulator for Deep Space Exploration Mission

被引:1
|
作者
Jia, Qingxuan [1 ]
Shao, Wen [1 ]
Chen, Gang [1 ]
Wang, Yifan [1 ]
Li, Lanpu [1 ]
机构
[1] Beijing Univ Posts & Telecommun, Beijing 100876, Peoples R China
基金
中国国家自然科学基金;
关键词
Self-calibration; Deep space exploration; Lander manipulator; MODEL;
D O I
10.1007/978-3-030-27538-9_30
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In view of the characteristics of the lander in deep space exploration mission, a self-calibration method of kinematics parameters is proposed; it uses the hand-eye camera at the end of the manipulator as the measuring equipment to calibrate the kinematics parameters of the manipulator carried on the lander. By establishing the kinematic model contains the relative pose of manipulator's base coordinate and target coordinate, and then establishing the kinematic error model of the lander manipulator system to realize the kinematics parameters calibration. The method realizes the kinematics parameters calibration under the condition of unknown of the relative pose of base coordinate system and target coordinate system, and calibrates the manipulator base coordinates in inertial system and the hand-eye relation at the same time. Through simulation experiments, it is verified that the self-calibration method proposed in this paper can obtain accurate kinematics parameters and effectively improve the accuracy of the lander manipulator terminal pose.
引用
收藏
页码:354 / 366
页数:13
相关论文
共 50 条
  • [31] Measurement data self-calibration fusion method
    Fu H.
    Yang H.
    Wen X.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (08): : 1759 - 1763
  • [32] A WEIGHTED ITERATIVE METHOD FOR ROBUST SELF-CALIBRATION
    Liu Shigang Wu Chengke Tang Li Jia Jing National Key Laboratory of ISN Xidian University Xian China
    JournalofElectronics, 2006, (05) : 713 - 717
  • [33] The self-calibration method of IR mixer with low IF
    Andrzej Szymański
    Ewa Kurjata-Pfitzner
    Jan Lesiński
    Jerzy Wąsowski
    Analog Integrated Circuits and Signal Processing, 2008, 55 : 115 - 124
  • [34] Self-calibration method for capacitor mismatch elimination
    Melikyan, Vazgen
    Aleksanyan, Ani
    Stepanyan, Harutyun
    Harutyunyan, Ani
    Durgaryan, Armen
    PROCEEDINGS OF IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS 2013), 2013,
  • [35] Self-Calibration Method for Accurate Direct-Current Ratio Calibration
    Zhai, Changwei
    Zhao, Jianting
    Lu, Yunfeng
    Hu, Pengcheng
    Zhou, Kunli
    ELECTRONICS, 2025, 14 (05):
  • [36] A laser sheet self-calibration method for scanning PIV
    Anna N. Knutsen
    John M. Lawson
    James R. Dawson
    Nicholas A. Worth
    Experiments in Fluids, 2017, 58
  • [37] CAMERA SELF-CALIBRATION: DEEP LEARNING FROM DRIVING SCENES
    Rachman, Arya
    Seiler, Jurgen
    Kaup, Andre
    2022 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP, 2022, : 2836 - 2840
  • [38] Visual servoing method using camera self-calibration
    Lee, Dong-Wook
    Kim, Se-Hoon
    Won, Sang-Chul
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 2649 - +
  • [39] Method of camera self-calibration based on a planar template
    Wang, Nian
    Fan, Yi-Zheng
    Liang, Dong
    Wei, Sui
    Jiqiren/Robot, 2004, 26 (06):
  • [40] A digital self-calibration method for pipeline A/D converters
    Sumanen, L
    Waltari, M
    Korhonen, T
    Halonen, K
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, PROCEEDINGS, 2002, : 792 - 795