Flow injection biamperometric determination of nitrite and nitrate

被引:0
|
作者
Danet, AF [1 ]
David, V [1 ]
机构
[1] Univ Bucharest, Fac Chem, Dept Analyt Chem, R-70031 Bucharest, Romania
关键词
nitrite; nitrate; biamperometry; flow injection;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and efficient FIA method was used with good results to determine nitrite in residual waters and nitrate in natural waters. Nitrite determination is based on the reaction with iodide occurring in acidic medium and biamperometric detection of the formed iodine at two platinum electrodes polarised at a potential of 100 mV. Nitrate is similarly determined after its previous reduction to nitrite in a cadmium column. me method does not need the solution deaeration. However, the calibration graphs present two regions of linearity owing to the catalytic effect of the dissolved oxygen on the iodide oxidation by nitrite.
引用
收藏
页码:751 / 764
页数:14
相关论文
共 50 条
  • [31] Spectrophotometric simultaneous determination of nitrite, nitrate and ammonium in soils by flow injection analysis
    Lopez Pasquali, C. E.
    Fernandez Hernando, P.
    Durand Alegria, J. S.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 177 - 182
  • [32] Flow injection biamperometric determination of metronidazole with on-line photodegradation
    Palomeque, M
    Bautista, JAG
    Mateo, JVG
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) : 229 - 236
  • [33] Indirect flow-injection determination of catecholamines with biamperometric detection
    Wolyniec, E
    Kojlo, A
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2003, 21 (02): : 217 - 227
  • [34] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE IN BIOLOGICAL SAMPLES BY MULTICHANNEL FLOW-INJECTION ANALYSIS
    PRATT, PF
    NITHIPATIKOM, K
    CAMPBELL, WB
    ANALYTICAL BIOCHEMISTRY, 1995, 231 (02) : 383 - 386
  • [35] Simultaneous determination of nitrite and nitrate in various samples using flow injection with spectrophotometric detection
    Ensafi, AA
    Kazemzadeh, A
    ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) : 15 - 21
  • [36] Simultaneous spectrophotometric determination of nitrite and nitrate in water samples by flow-injection analysis
    Chen, H
    Fang, YJ
    An, TC
    Zhu, K
    Lu, JR
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (02) : 89 - 98
  • [37] Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples
    Burakham, R
    Oshima, M
    Grudpan, K
    Motomizu, S
    TALANTA, 2004, 64 (05) : 1259 - 1265
  • [38] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [39] A flow-injection biamperometric method for determination of pantoprazole in pharmaceutical tablets
    Castro, SL
    Pessoa-Neto, OD
    Santos, SRB
    Medeiros, EP
    Lima, RAC
    Martins, VL
    Araújo, MCU
    Santos, JCC
    Korn, M
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (04) : 1064 - 1068