A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

被引:20
|
作者
Jeong, Yuri [1 ]
Lee, Sang-wook [1 ]
Kwak, Jungwon [1 ]
Cho, Ilsung [1 ]
Yoon, Sang Min [1 ]
Kim, Jong Hoon [1 ]
Park, Jin-hong [1 ]
Choi, Eun Kyung [1 ]
Song, Si Yeol [1 ]
Kim, Young Seok [1 ]
Kim, Su Ssan [1 ]
Joo, Ji Hyeon [1 ]
Ahn, Seung Do [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiat Oncol, Seoul 138736, South Korea
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
Paranasal sinus cancer; Nasal cavity cancer; Volumetric modulated arc therapy; Non-coplanar intensity modulated radiotherapy; Planning target volume; Organs at risk; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; SIMULTANEOUS INTEGRATED BOOST; DELIVERY TIME; RADIATION-THERAPY; SINGLE-ARC; TUMOR-CONTROL; NECK-CANCER; IN-VIVO; CARCINOMAS; IMPACT;
D O I
10.1186/1748-717X-9-193
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). Methods: Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan and non-coplanar IMRT (7-, 11-, and 15-beam) plans. Planning objectives were to deliver 60 Gy in 30 fractions to 95% of PTV, with maximum doses (D-max) of <50 Gy to the optic nerves, optic chiasm, and brainstem, <40 Gy to the eyes and <10 Gy to the lenses. The target mean dose (D-mean) to the parotid glands was <25 Gy, and no constraints were applied to the lacrimal glands. Planning was optimized to minimized doses to OAR without compromising coverage of the PTV. VMAT and three non-coplanar IMRT (7-, 11-, and 15-beam) plans were compared using the heterogeneity and conformity indices (HI and CI) of the PTV, D-max and D-mean of the OAR, treatment delivery time, and monitor units (MUs). Results: The HI and CI of VMAT plan were superior to those of the 7-, 11-, and 15-beam non-coplanar IMRT. VMAT and non-coplanar IMRT (7-, 11-, and 15-beam) showed equivalent sparing effects for the optic nerves, optic chiasm, brainstem, and parotid glands. For the eyes and lenses, VMAT achieved equivalent or better sparing effects when compared with the non-coplanar IMRT plans. VMAT showed lower MUs and reduced treatment delivery time when compared with non-coplanar IMRT. Conclusions: In 10 patients with nasal cavity or paranasal sinus cancer, a VMAT plan provided better homogeneity and conformity for PTV than non-coplanar IMRT plans, with a shorter treatment delivery time, while achieving equal or better OAR-sparing effects and using fewer MUs.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [12] Dosimetric Comparison of Adjuvant Pelvic Radiotherapy for Endometrial Cancer using Intensity-Modulated Radiotherapy (IMRT), Volumetric Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT)
    Temelli, Oztun
    Demirtas, Mehmet
    Sisecioglu, Mahmut Serdar
    Pepele, Eda Kaya
    EURASIAN JOURNAL OF MEDICINE AND ONCOLOGY, 2019, 3 (03): : 203 - 210
  • [13] Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience
    Ostheimer, Christian
    Huebsch, Patrick
    Janich, Martin
    Gerlach, Reinhard
    Vordermark, Dirk
    RADIATION ONCOLOGY JOURNAL, 2016, 34 (04): : 313 - 321
  • [14] Dosimetric comparison of volumetric-modulated arc therapy (VMAT) and fixed field intensity-modulated radiotherapy (IMRT) in patients with nasal tumor: a meta-analysis
    Feng, W. G.
    Ma, W.
    Li, Sh P.
    Guo, Y. X.
    Du, W.
    Cai, H. Y.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 561 - 569
  • [15] Comparison of non coplanar and coplanar beam arrangements in intensity modulated radiation therapy (IMRT) for paranasal sinus carcinoma
    Morris, K
    Huang, Y
    Hunt, M
    Lee, LN
    Wuu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1873 - 1873
  • [16] Volumetric Modulated Arc Therapy (VMAT) Versus Intensity Modulated Radiation Therapy (IMRT) in Pelvic Malignancies: A Dosimetric Analysis
    Jain, S.
    Babaiah, M.
    Mohanty, P.
    Mirza, A.
    Ramalingam, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S752 - S752
  • [17] Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis
    Torizuka, Daichi
    Uto, Megumi
    Takehana, Keiichi
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1114 - 1119
  • [18] Coplanar vs. Non-coplanar Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Fronto-Temporal High Grade Glioma (HGG)
    Vlachaki, M. T.
    Panet-Raymond, V.
    Zavgorodni, S.
    Bendorffe, W.
    Nichol, A.
    Beckham, W.
    Truong, P. T.
    Ansbacher, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S832 - S832
  • [19] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [20] Automated Non-coplanar Volumetric Modulated Arc Therapy Planning for Maxillary Sinus Carcinoma
    Ohira, Shingo
    Inui, Shoki
    Kanayama, Naoyuki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Konishi, Koji
    IN VIVO, 2023, 37 (01): : 417 - 423