Quantitative determination of wine polyfunctional mercaptans at nanogram per liter level by gas chromatography-negative ion mass spectrometric analysis of their pentafluorobenzyl derivatives

被引:46
|
作者
Mateo-Vivaracho, Laura [1 ]
Cacho, Juan [1 ]
Ferreira, Vicente [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, Lab Flavour Anal & Enol, E-50009 Zaragoza, Spain
关键词
thiols; mercaptans; pentafluorobenzylbromide; wine; aroma; flavour; GC-NCI-MS;
D O I
10.1016/j.chroma.2007.02.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast method for the determination of aroma-powerful polyfunctional thiols at nanogram per liter level has been developed and applied to wine. A small volume of wine (6 mL) was extracted with 1.5 mL of benzene containing four internal standards. Pentafluorobenzyl derivatives of mercaptans were formed in the extract by adding small amounts (100 mg L-1) of pentafluorobenzyl bromide and a strong alkali: 1,8-diazabicyclo[5.4.0]undec-7ene (DBU). After washing with a water:methanol (5: 1) solution 0.5 M in HC1, 20 mu L of the extract was directly injected into a gas chromatograph. Derivatives were detected by negative ion mass spectrometry. The method makes it possible to simultaneously determine 2-furfurylthiol (2furanmethanethiol) (FFT), 4-mercapto-4-methyl-2-pentanone (MP), 3-mercaptohexylacetate (MHA) and 3-mercaptohexanol (MH). Inconsistent results were obtained for 2-methyl-3-furanthiol (MF). Detection limits were 0.5 ng L-1 (FFr), 0. 1 ng L-1 (MP), 0.6 ng L-1 (MHA) and 7 ng L-1 (MH), well below the corresponding odor detection thresholds. Method repeatability (10% < RSD < 17%) and linearity (0.98 < R-2 < 0.999) were satisfactory. The linear range was more than 2 orders of magnitude wide, covering the natural range of occurrence of these compounds in wine, and the slopes of the standard addition plots from different wines were very similar. The different aspects of the method optimization are discussed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 50 条
  • [21] Gas chromatography-negative ion chemical ionisation mass spectrometry using o-(pentafluorobenzyloxycarbonyl)-2,3,4,5-tetrafluorobenzoyl derivatives for the quantitative determination of methylphenidate in human plasma
    Leis, Hans J.
    Windischhofer, Werner
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2299 - 2303
  • [22] DETERMINATION OF ALKYLMERCURY IN SEAWATER AT THE NANOGRAM PER LITER LEVEL BY GAS-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA EMISSION-SPECTROMETRY
    CHIBA, K
    YOSHIDA, K
    TANABE, K
    HARAGUCHI, H
    FUWA, K
    ANALYTICAL CHEMISTRY, 1983, 55 (03) : 450 - 453
  • [23] Multiresidue Determination of Organophosphorus Pesticide Residues in Vegetables and Fruit by Gas Chromatography-Negative Ion Chemical Ionization-Mass Spectrometry
    Lin Zhuguang
    Fan Yulan
    Ma Yu
    Jin Zhen
    Tan Jun
    Chen Meiyu
    Chen Zhaobin
    Tu Fengzhang
    Liu Yong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (03) : 221 - 227
  • [24] Critical aspects of the determination of pentafluorobenzyl derivatives of aldehydes by gas chromatography with electron-capture or mass spectrometric detection -: Validation of an optimized strategy for the determination of oxygen-related odor-active aldehydes in wine
    Ferreira, Vicente
    Cullere, Laura
    Loscos, Natalia
    Cacho, Juan
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) : 255 - 265
  • [25] ANALYSIS OF BIOGENIC-AMINES IN BOVINE RETINA BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    MACFARLANE, RG
    MACLEOD, SC
    MIDGLEY, JM
    WATSON, DG
    JOURNAL OF NEUROCHEMISTRY, 1989, 53 (06) : 1731 - 1736
  • [26] Determination of fetal bile acids in biological fluids from neonates by gas chromatography-negative ion chemical ionization mass spectrometry
    Murai, T
    Mahara, R
    Kurosawa, T
    Kimura, A
    Tohma, M
    JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01): : 13 - 22
  • [27] Trace analysis of tributyltin and triphenyltin compounds in sea water by gas chromatography-negative ion chemical ionization mass spectrometry
    Mizuishi, K
    Takeuchi, M
    Hobo, T
    JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (02) : 267 - 273
  • [28] Analysis of a stable halogenated derivative of muramic acid by gas chromatography-negative ion chemical ionization tandem mass spectrometry
    Kozar, MP
    Fox, A
    JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 229 - 238
  • [29] Determination of organophosphorus pesticide residues in human tissues by capillary gas chromatography-negative chemical ionization mass spectrometry analysis
    Russo, MV
    Campanella, L
    Avino, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 431 - 441
  • [30] NEGATIVE-ION CHEMICAL IONIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF PROSTANOID PENTAFLUOROBENZYL ESTER METHOXIME TRIMETHYLSILYL ETHER DERIVATIVES
    SCHWEER, H
    SEYBERTH, HW
    MEESE, CO
    FURST, O
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (03): : 143 - 151