Respiration-induced attenuation artifact at PET/CT: Technical considerations

被引:150
|
作者
Goerres, GW
Burger, C
Kamel, E
Seifert, B
Kaim, AH
Buck, A
Buehler, TC
von Schulthess, GK
机构
[1] Univ Zurich, Div Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Dept Biostat, CH-8091 Zurich, Switzerland
关键词
heart; PET; images; processing; lung; positron emission tomography (PET); artifact; technology;
D O I
10.1148/radiol.2263011732
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Combined positron emission tomographic (PET)/computed tomographic (CT) scanners allow the use of CT data for attenuation correction of PET images. Eight patients with cancer underwent PET/CT scanning. Transmission scanning was performed with conventional attenuation correction and with CT scanning during maximum inspiration and normal expiration. Image quality was visually compared and fluorine 18 activities were measured in volumes of interest in the lung and myocardium. Analysis of variance for repeated measures revealed a significant decrease (P = .0001) in measured activities be tween PET images corrected with CT data acquired during maximum inspiration and those corrected with the conventional attenuation correction method or with CT data acquired during normal expiration. Deep inspiration during CT can result in severe deterioration in the final PET image. (C) RSNA, 2003.
引用
收藏
页码:906 / 910
页数:5
相关论文
共 50 条
  • [31] Two neural mechanisms for respiration-induced cutaneous vasodilatation in humans
    Wallin, BG
    Båtelsson, K
    Kienbaum, P
    Karlsson, T
    Gazelius, B
    Elam, M
    JOURNAL OF PHYSIOLOGY-LONDON, 1998, 513 (02): : 559 - 569
  • [32] RESPIRATION-INDUCED OXYGEN GRADIENTS IN CULTURED-MAMMALIAN-CELLS
    FENGLER, JJP
    DURAND, RE
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1990, 58 (01) : 133 - 144
  • [33] Quantification of respiration-induced dosimetric impact on liver for abdominal radiotherapy
    Lin, L.
    Shi, C.
    Salter, B.
    Fuss, M.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2006, 33 (06) : 2174 - 2175
  • [34] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942
  • [35] A Novel Approach for Reducing Dental Filling Artifact in CT-Based Attenuation Correction of PET Data
    Abdoli, M.
    Ay, M. R.
    Ahmadian, A.
    Sahba, N.
    Zaidi, H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 492 - 495
  • [36] The battle against respiration-induced organ motion in external beam radiotherapy
    Alnowami, Majdi R.
    Hagi, Sarah K.
    SAUDI MEDICAL JOURNAL, 2014, 35 (07) : 651 - 662
  • [37] Attenuation artifact from sclerotic bone can mimic active bone metastasis on PET-CT
    Ho, Linh
    Seto, John
    CLINICAL NUCLEAR MEDICINE, 2006, 31 (11) : 724 - 726
  • [38] The analysis of respiration-induced pancreatic tumor motion based on reference measurement
    Lukas Knybel
    Jakub Cvek
    Bretislav Otahal
    Tomas Jonszta
    Lukas Molenda
    Daniel Czerny
    Eva Skacelikova
    Marian Rybar
    Pavel Dvorak
    David Feltl
    Radiation Oncology, 9
  • [39] Respiration-Induced Movement Correlation for Synchronous Noninvasive Renal Cancer Surgery
    Abhilash, Rakkunedeth H.
    Chauhan, Sunita
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) : 1478 - 1486
  • [40] Respiration-induced hypoalgesia: Additional evidence for pain modulation deficits in fibromyalgia?
    Rhudy, Jamie L.
    PAIN, 2010, 149 (01) : 1 - 2