The reliability and validity of passive leg raise and fluid bolus to assess fluid responsiveness in spontaneously breathing emergency department patients

被引:29
|
作者
Duus, Nicolaj [1 ,2 ]
Shogilev, Daniel J. [5 ]
Skibsted, Simon [1 ,2 ]
Zijlstra, Hendrik W. [1 ]
Fish, Emily [3 ]
Oren-Grinberg, Achikam [3 ]
Lior, Yotam [4 ]
Novack, Victor [4 ]
Talmor, Daniel [3 ]
Kirkegaard, Hans [2 ]
Shapiro, Nathan I. [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Emergency Med, Boston, MA 02215 USA
[2] Aarhus Univ Hosp, Res Ctr Emergency Med, DK-8000 Aarhus, Denmark
[3] Beth Israel Deaconess Med Ctr, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02215 USA
[4] Ben Gurion Univ Negev, Fac Hlth Sci, Soroka Univ Med Ctr, Clin Res Ctr, Beer Sheva, Israel
[5] Duke Univ, Div Emergency Med, Durham, NC USA
关键词
Fluid resuscitation; Noninvasive monitoring; Passive leg raise; Fluid bolus; Fluid responsiveness; CARDIAC-OUTPUT; PRESSURE; BIOREACTANCE; DOPPLER; FLOTRAC;
D O I
10.1016/j.jcrc.2014.07.031
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. Methods: Prospective, observational study of a convenience sample of adult ED patients receiving intravenous fluid bolus. We assessed stroke volume (SV) using NICOM and obtained results from PLR, where the head of the bed was changed from semirecumbent to supine while the patients' legs raised to 45 degrees for 3 minutes. Fluid bolus was defined as 5 mL/kg normal saline infusion. Maximal increase in SV was recorded. Fluid responsiveness was defined as an increase of SV greater than 10% from baseline. We obtained 4 consecutive responses for each patient; PLR1, PLR2, BOLUS1 separated each by 10 minutes, and BOLUS2 initiated immediately after the end of BOLUS1. We calculated. statistics, correlation coefficients, and odds ratios with 95% confidence interval and Bland-Altman plots. Results: We enrolled 109 patients enrolled in this study. The 2 PLRs were significantly correlated (r = 0.78, P < .001) with kappa = 0.46 for FR(P < .001). The 2 BOLUSES less strongly correlated (r = 0.14, P = .001) and kappa = 0.06 for FR (P < .001). Patients who were responsive to PLR1 had 9.5 (3.6-25) odds of being FR for PLR2, whereas those responsive to BOLUS1 had a 1.8 (0.76-4.3) increased odds of FR for BOLUS2. Conclusion: In conclusion, we have found PLR as measured by the NICOM to be a promising tool for the evaluation of SV responsiveness. It was feasible for use in the ED, and the data suggest that the PLR technique may be more reproducible than the fluid bolus technique for assessing volume responsiveness. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:217.e1 / 217.e5
页数:5
相关论文
共 50 条
  • [21] FLUID RESPONSIVENESS AND THE PASSIVE LEG RAISE: KNOWLEDGE, EXPERIENCES, AND ATTITUDES OF AN ICU NURSING COHORT
    Mullen, Louise
    NURSING IN CRITICAL CARE, 2022, 27 : 34 - 34
  • [22] Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test
    Brahim Benomar
    Alexandre Ouattara
    Philippe Estagnasie
    Alain Brusset
    Pierre Squara
    Intensive Care Medicine, 2010, 36 : 1875 - 1881
  • [23] Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test
    Benomar, Brahim
    Ouattara, Alexandre
    Estagnasie, Philippe
    Brusset, Alain
    Squara, Pierre
    INTENSIVE CARE MEDICINE, 2010, 36 (11) : 1875 - 1881
  • [24] Evaluation of Carotid Flow Time to Assess Fluid Responsiveness in the Emergency Department
    Judson, P. Immanuel
    Abhilash, Kundavaram Paul Prabhakar
    Pichamuthu, Kishore
    Chandy, Gina Maryann
    JOURNAL OF MEDICAL ULTRASOUND, 2021, 29 (02) : 99 - 104
  • [25] Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature
    de Freitas Chaves, Renato Carneiro
    Correa, Thiago Domingos
    Serpa Neto, Ary
    Bravim, Bruno de Arruda
    Cordioli, Ricardo Luiz
    Moreira, Fabio Tanzillo
    Timenetsky, Karina Tavares
    Cesar de Assuncao, Murillo Santucci
    ANNALS OF INTENSIVE CARE, 2018, 8
  • [26] Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature
    Renato Carneiro de Freitas Chaves
    Thiago Domingos Corrêa
    Ary Serpa Neto
    Bruno de Arruda Bravim
    Ricardo Luiz Cordioli
    Fabio Tanzillo Moreira
    Karina Tavares Timenetsky
    Murillo Santucci Cesar de Assunção
    Annals of Intensive Care, 8
  • [27] Cardiac output monitoring and fluid responsiveness in spontaneously breathing patients reply
    Piraccini, E.
    Corso, R. M.
    Agnoletti, V.
    Gambale, G.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (04) : 359 - 360
  • [28] Passive leg raising as an indicator of fluid responsiveness in patients with severe sepsis
    Dong, Zhou-zhou
    Fang, Qiang
    Zheng, Xia
    Shi, Heng
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2012, 3 (03) : 191 - 196
  • [29] Passive leg raising as an indicator of fluid responsiveness in patients with severe sepsis
    Zhou-zhou Dong
    Qiang Fang
    Xia Zheng
    Heng Shi
    World Journal of Emergency Medicine, 2012, (03) : 191 - 196
  • [30] Passive leg raising as an indicator of fluid responsiveness in patients with severe sepsis
    Zhouzhou Dong
    Qiang Fang
    Xia Zheng
    Heng Shi
    World Journal of Emergency Medicine, 2012, 3 (03) : 191 - 196