Operational experience with the silicon detector at CDF

被引:1
|
作者
Wagner, Jeannine [1 ]
机构
[1] Univ Karlsruhe, Inst Expt Kernphys, D-76131 Karlsruhe, Germany
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2007年 / 576卷 / 01期
关键词
CDF; silicon detectors; radiation damage;
D O I
10.1016/j.nima.2007.01.156
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CDF Run II silicon vertex detector is the largest operating silicon detector in high-energy physics. Besides being very important for tracking, the silicon detector plays a vital role in the level 2 decision making of the CDF trigger system. The silicon detector consists of eight layers of silicon with more than 720 000 readout channels. Since the commissioning period ended in 2002 the detector has been operating reliably and it has recorded more than 1.5 fb(-1) of data. A summary of the operational experience with the silicon detector at CDF is given and aspects of the longevity of the detector are discussed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 222
页数:3
相关论文
共 50 条
  • [41] Status and performance of the CDF Run II silicon detector
    Maki, Tuula
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 723 - 725
  • [42] CDF Run IIb silicon detector:: The innermost layer
    Merkel, P
    Azzi, P
    Bacchetta, N
    Bisello, D
    Busetto, G
    Hara, K
    Kim, S
    Manea, C
    Wang, Z
    Behari, S
    Maksimovic, P
    Benjamin, D
    Cabrera, S
    Kruse, M
    Bolla, G
    Bortoletto, D
    Canepa, A
    Fernandez, JP
    Booth, P
    Cooke, P
    Cascella, M
    Cardoso, G
    Derylo, G
    Flaugher, B
    Hrycyk, M
    Kuznetsova, N
    Lukens, P
    Nelson, T
    Orlov, Y
    Wester, W
    Yun, JC
    Chertok, M
    Holbrook, B
    Lander, R
    Landry, T
    Pellett, D
    Soha, A
    Yao, W
    Ciobanu, CI
    Junk, T
    Feng, EJ
    Freeman, J
    Galtieri, L
    García-Sciveres, M
    Haber, C
    Lujan, PJ
    Mandelli, E
    Weber, M
    Yao, W
    Zetti, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2215 - 2219
  • [43] CDF:: B physics performance and trigger -: Operational experience
    Annovi, A.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 170 : 283 - 287
  • [44] Status and performance of the CDF Run II silicon detector
    Wallny, RS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 56 - 59
  • [45] THE CDF SVX - A SILICON VERTEX DETECTOR FOR A HADRON COLLIDER
    CARITHERS, WC
    ELY, RP
    HABER, C
    HOLLAND, S
    KIRSTEN, F
    KLEINFELDER, S
    SPIELER, H
    WESTER, WC
    WONG, M
    BEDESCHI, F
    GALEOTTI, S
    MENZIONE, A
    PUNZI, G
    RAFFAELLI, F
    ZETTI, F
    AMIDEI, D
    BOHN, T
    CARTER, H
    HYRCYK, M
    KEPHART, R
    NELSON, C
    SEGLER, S
    TOUSIGNANT, D
    TKACEK, S
    TOLLESTRUP, A
    TURNER, K
    YAREMA, R
    ZIMMERMANN, T
    BOSWELL, C
    MATTHEWS, J
    VEJCIK, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (03): : 388 - 399
  • [46] Radiation Life of the CDF Run II Silicon Detector
    Redondo, Ignacio
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 503 - 506
  • [47] The CDF RUN II Silicon Detector: Aging Studies
    Redondo Fernandez, Ignacio
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 451 - 455
  • [48] Status and radiation hardness of the CDF RunII silicon detector
    Lu, RS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 552 (1-2): : 219 - 223
  • [49] CDF SVX II upgrade silicon detector: Silicon sensors performances
    Purdue Univ, West Lafayette, United States
    Nucl Instrum Methods Phys Res Sect A, 1-3 (112-116):
  • [50] Status and performance of the CDF Run II silicon detector
    Wallny, RS
    ICHEP 2005: PROCEEDINGS OF THE 32ND INTERNATIONAL CONFERENCE HIGH ENERGY PHYSICS VOLS 1 AND 2, 2005, : 953 - 955