Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

被引:55
|
作者
Causone, Francesco [1 ]
Corgnati, Stefano P. [1 ]
Filippi, Marco [1 ]
Olesen, Bjarne W. [2 ]
机构
[1] Politecn Torino, Dept Energet, TEBE Res Grp, I-10129 Turin, Italy
[2] Tech Univ Denmark, ICIEE, Dept Civil Engn, DK-2800 Lyngby, Denmark
关键词
Solar radiation; Solar heat gains; Cooling load; Radiant panels; Heat Balance; Radiant Time Series; GLAZED SPACES; SIMULATION;
D O I
10.1016/j.enbuild.2009.09.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling, is calculated for different kinds of office rooms with a large glazed external surface. An example of cooling load calculation developed with the proposed procedure is given. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 50 条
  • [41] Solar Power Controller to Drive Load at Constant Power under Insufficient Solar Radiation
    Ahammed, Md. Tanvir
    Islam, Md. Rafiqul
    2016 4TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT IN THE IN RENEWABLE ENERGY TECHNOLOGY (ICDRET), 2016,
  • [42] Evaluation of hybrid solar-biomass dryer with no load
    Yassen, Tadahmun Ahmed
    Al-Kayiem, Hussain H.
    Habib, Khairul
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [43] A revised radiant time series method (RTSM) to calculate the cooling load for pipe-embedded radiant systems
    Ning, Baisong
    Zhang, Mengdi
    Li, Jiayu
    Chen, Youming
    ENERGY AND BUILDINGS, 2022, 268
  • [44] LOAD OPTIMIZATION IN SOLAR SPACE HEATING-SYSTEMS
    BARLEY, CD
    SOLAR ENERGY, 1979, 23 (02) : 149 - 156
  • [45] Power Management of Solar PV Systems for PEER Load
    Usmani, Mohammad Jasim
    Haque, Ahteshamul
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (06) : 6327 - 6338
  • [46] Dynamic Load Calculation of Solar Radiation Heat Gain for Energy-saving Buildings Envelope in Winter
    Wang Xuejin
    Zhang Yujing
    Hong Jing
    2020 4TH INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2020), 2020, 510
  • [47] COOLING LOAD CALCULATION - ART OR SCIENCE
    ROMINE, TB
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (01): : 14 - &
  • [48] Passive Method to reduce solar energy effect on the cooling load in buildings
    Mohamad, A. A.
    Alansary, H.
    Orfi, J.
    2ND EUROPEAN ENERGY CONFERENCE, 2012, 33
  • [49] Calculating the load on the room cooling ceiling panel at solar heat gains
    Malyavina, E. G.
    Lomakin, A. G.
    INTERNATIONAL SCIENTIFIC CONFERENCE ENERGY MANAGEMENT OF MUNICIPAL FACILITIES AND SUSTAINABLE ENERGY TECHNOLOGIES, 2020, 1614
  • [50] Part-load based optimization of solar ejector cooling cycle
    Braimakis, Konstantinos
    Kitsopoulou, Angeliki
    Roumpedakis, Tryfon C.
    Stavrakakis, George M.
    Tzivanidis, Christos
    RENEWABLE ENERGY, 2025, 243