Load-frequency control in a multi-source power system connected to wind farms through multi terminal HVDC systems

被引:42
|
作者
Tavakoli, Mehdi [1 ]
Pouresmaeil, Edris [2 ,3 ]
Adabi, Jafar [4 ]
Godina, Radu [5 ]
Catalao, Joao P. S. [3 ,5 ,6 ,7 ]
机构
[1] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol Sar, Mazandaran, Iran
[2] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[3] Univ Lisbon, Inst Super Tecn, INESC ID, P-1049001 Lisbon, Portugal
[4] Babol Noshirvani Univ Technol, Fac Elect & Comp Engn, POB 484, Babol Sar, Iran
[5] Univ Beira Interior, C MAST, P-6201001 Covilha, Portugal
[6] Univ Porto, INESC TEC, P-4200465 Porto, Portugal
[7] Univ Porto, Fac Engn, P-4200465 Porto, Portugal
关键词
Frequency control; Particle swarm optimization (PSO); Wind farm; Multi-terminal HVDC; AUTOMATIC-GENERATION CONTROL; DIFFERENTIAL EVOLUTION ALGORITHM; TRANSMISSION; PARAMETERS; DESIGN;
D O I
10.1016/j.cor.2018.03.002
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper addresses the wind farm contribution in frequency control during the integration in the power grid. In the proposed model, the wind farm utilizes inertia control and droop control techniques with the purpose of improving the frequency regulation. In order to achieve optimal results, all the parameters of the controllers for the different units in the power grid are obtained by using a particle swarm optimization algorithm (PSO) and by introducing a modified objective function instead of a conventional objective function e.g., Integral Time-weighted Absolute Error (ITAE). Also, different constraints such as reheat turbine, time delay, governor dead band and generation rate constraint (GRC) are considered for thermal and hydro units with the aim of studying a more realistic power system, which is the main contribution of this paper when compared to the other works in this field. It is shown that, in case of a perturbation in power demand, the system frequency will recover quickly and effectively in comparison with the traditional approaches. In addition, a sensitivity test is carried out in a single power grid area in order to examine the effectiveness of the proposed approach. Then, the system is extended to a multi-area power system using a multi-terminal HVDC for further investigation of the suggested strategy. Simulation results are presented in order to assess the performance of the proposed approach in the power system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 315
页数:11
相关论文
共 50 条
  • [31] A multi-terminal VSC-HVDC system control strategy for large wind farms integration
    Li, Chenghao
    Zhan, Peng
    Wen, Jinyu
    Luo, Weihua
    Gao, Kai
    Zhang, Zhonglin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 1 - 7
  • [32] Load Frequency Control Assessment of a PSO-PID Controller for a Standalone Multi-Source Power System
    Dhanasekaran, Boopathi
    Kaliannan, Jagatheesan
    Baskaran, Anand
    Dey, Nilanjan
    Tavares, Joao Manuel R. S.
    TECHNOLOGIES, 2023, 11 (01)
  • [33] Discrete-Time Optimal Controller for Load Frequency Control of Multi-Source Power System in Egypt
    Magdy, G.
    Bakeer, Abualkasim
    Shabib, G.
    Elbaset, Adel A.
    Mitani, Yasunori
    PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON INNOVATIVE TRENDS IN COMPUTER ENGINEERING (ITCE' 2018), 2018, : 264 - 270
  • [34] Modeling and control of multi terminal VSC HVDC transmission system for integrating large offshore wind farms
    Ali Raza
    Xu Dianguo
    Su Sunwen
    Li Wiexing
    17TH IEEE INTERNATIONAL MULTI TOPIC CONFERENCE 2014, 2014, : 467 - 472
  • [35] Backstepping DC Voltage Control in a Multi-terminal HVDC System Connecting Offshore Wind Farms
    Zhao, Xiaodong
    Li, Kang
    Xue, Yusheng
    INTELLIGENT COMPUTING IN SMART GRID AND ELECTRICAL VEHICLES, 2014, 463 : 286 - 295
  • [36] Offshore Wind Farms Integration and Frequency Support Control Utilizing Hybrid Multi-terminal HVDC Transmission
    Li, Cheng-hao
    Zhan, Peng
    Wen, Jin-yu
    Yao, Mei-qi
    Li, Nai-hu
    Lee, Wei-jen
    2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [37] Analyzing Small-Signal Stability in a Multi-Source Single-Area Power System with a Load-Frequency Controller Coordinated with a Photovoltaic System
    Shahgholian, Ghazanfar
    Fathollahi, Arman
    APPLIEDMATH, 2024, 4 (02): : 452 - 467
  • [38] Distributed Primary Frequency Control through Multi-Terminal HVDC Transmission Systems
    Andreasson, Martin
    Wiget, Roger
    Dimarogonas, Dimos V.
    Johansson, Karl H.
    Andersson, Goeran
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 5029 - 5034
  • [39] Highly-proportional Wind Power System Multi-Source Collaborate Load Frequency Control Strategy Based on Distributed Model Prediction
    Yang D.
    Zhu J.
    Jiang C.
    Hao Z.
    Zhao G.
    Dianwang Jishu/Power System Technology, 2024, 48 (07): : 2804 - 2814
  • [40] Coordinated control for multi terminal DC grids connected to offshore wind farms
    Rault, P.
    Freytes, J.
    Guillaud, X.
    Colas, F.
    Saad, H.
    Despouys, O.
    Nguefeu, S.
    2016 IEEE 17TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2016,