Cycling coal and natural gas-fired power plants with CCS

被引:14
|
作者
Versteeg, Peter [1 ]
Oates, David Luke [1 ]
Hittinger, Eric [2 ]
Rubin, Edward S. [1 ]
机构
[1] Carnegie Mellon Univ, Dept Engn & Publ Policy, 5000 Forbes Ave, Pittsburgh, PA 15213 USA
[2] Rochester Inst Technol, Dept STS Publ Policy, Rochester, NY 14623 USA
来源
GHGT-11 | 2013年 / 37卷
关键词
post-combustion; carbon capture and sequestration; variable electricity prices; POSTCOMBUSTION CO2 CAPTURE; STORAGE;
D O I
10.1016/j.egypro.2013.06.152
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The profitability impacts of solvent storage are modeled for new coal and natural gas-fired power plants with amine and ammonia-based post-combustion CCS facing variable electricity prices. With perfect information of future prices, up to 3 hours of solvent storage was valuable due to price volatility at carbon prices up to $40/tonne CO2 and no regenerator undersize. With imperfect information with relaxed constraints on regenerator undersizing, up to 8 hours of solvent storage was valuable when coupled with an undersized CO2 capture system at carbon prices up to $60/tonne CO2. The results indicate that storage does not have value above the breakeven CO2 price for these plants. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2676 / 2683
页数:8
相关论文
共 50 条
  • [21] Combining solar power with coal-fired power plants, or cofiring natural gas
    Mills, Stephen
    CLEAN ENERGY, 2018, 2 (01): : 1 - 9
  • [22] Topping with a Natural Gas-Fired Combined Cycle Unit of a Coal-Fired Cogeneration Power Plant with Cross Connections
    Borush, O. V.
    Shchinnikov, P. A.
    Frantseva, A. A.
    THERMAL ENGINEERING, 2021, 68 (01) : 65 - 71
  • [23] Topping with a Natural Gas-Fired Combined Cycle Unit of a Coal-Fired Cogeneration Power Plant with Cross Connections
    O. V. Borush
    P. A. Shchinnikov
    A. A. Frantseva
    Thermal Engineering, 2021, 68 : 65 - 71
  • [24] Exergetic analysis and evaluation of coal-fired supercritical thermal power plant and natural gas-fired combined cycle power plant
    Reddy, V. Siva
    Kaushik, S. C.
    Tyagi, S. K.
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2014, 16 (03) : 489 - 499
  • [25] Exergetic analysis and evaluation of coal-fired supercritical thermal power plant and natural gas-fired combined cycle power plant
    V. Siva Reddy
    S. C. Kaushik
    S. K. Tyagi
    Clean Technologies and Environmental Policy, 2014, 16 : 489 - 499
  • [26] MORE ON GAS-FIRED HEATING PLANTS
    PAYNE, JM
    ASHRAE JOURNAL, 1969, 11 (06): : 6 - &
  • [27] Importance of Gas-Fired Power Plants Location in Integrated Operation of Power and Natural Gas systems: Peak Load Condition Analysis
    Ghasemi, Masoud
    Mashhadi, Habib Rajabi
    Hejazy, Amin
    26TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE 2018), 2018, : 1227 - 1232
  • [28] Primary measures for reducing NO(x) levels of old coal and gas-fired plants
    Ebeling, H.-J.
    Fleskes, H.
    Elektrizitatswirtschaft, 1987, 86 (10): : 383 - 388
  • [29] Towards the hybridization of gas-fired power plants: A case study of Algeria
    Antonanzas, J.
    Alia-Martinez, M.
    Martinez-de-Pison, F. J.
    Antonanzas-Torres, F.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 51 : 116 - 124
  • [30] Gas-fired anti-icing for LM series power plants
    Anon
    Gas Turbine World, 2001, 31 (02):