Stacked Sparse Autoencoders for EMG-Based Classification of Hand Motions: A Comparative Multi Day Analyses between Surface and Intramuscular EMG

被引:44
|
作者
Rehman, Muhammad Zia Ur [1 ]
Gilani, Syed Omer [1 ]
Waris, Asim [1 ,2 ]
Niazi, Imran Khan [1 ,2 ,3 ]
Slabaugh, Gregory [4 ]
Farina, Dario [5 ]
Kamavuako, Ernest Nlandu [6 ]
机构
[1] NUST, Sch Mech & Mfg Engn, Dept Robot & Artificial Intelligence, Islamabad 44000, Pakistan
[2] Aalborg Univ, Dept Hlth Sci & Technol, Ctr Sensory Motor Interact, DK-9200 Aalborg, Denmark
[3] New Zealand Coll Chiropract, Ctr Chiropract Res, Auckland 1060, New Zealand
[4] City Univ London, Dept Comp Sci, London EC1V 0HB, England
[5] Imperial Coll London, Dept Bioengn, London SW7 2AZ, England
[6] Kings Coll London, Dept Informat, Ctr Robot Res, London WC2G 4BG, England
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 07期
关键词
deep networks; myocontrol; biomedical signal processing; surface EMG; intramuscular EMG; autoencoders; MYOELECTRIC CONTROL; PATTERN-RECOGNITION; PROSTHESIS CONTROL; SIGNALS; IDENTIFICATION; STRATEGY;
D O I
10.3390/app8071126
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Advances in myoelectric interfaces have increased the use of wearable prosthetics including robotic arms. Although promising results have been achieved with pattern recognition-based control schemes, control robustness requires improvement to increase user acceptance of prosthetic hands. The aim of this study was to quantify the performance of stacked sparse autoencoders (SSAE), an emerging deep learning technique used to improve myoelectric control and to compare multiday surface electromyography (sEMG) and intramuscular (iEMG) recordings. Ten able-bodied and six amputee subjects with average ages of 24.5 and 34.5 years, respectively, were evaluated using offline classification error as the performance matric. Surface and intramuscular EMG were concurrently recorded while each subject performed 11 hand motions. Performance of SSAE was compared with that of linear discriminant analysis (LDA) classifier. Within-day analysis showed that SSAE (1.38 +/- 1.38%) outperformed LDA (8.09 +/- 4.53%) using both the sEMG and iEMG data from both able-bodied and amputee subjects (p < 0.001). In the between-day analysis, SSAE outperformed LDA (7.19 +/- 9.55% vs. 22.25 +/- 11.09%) using both sEMG and iEMG data from both able-bodied and amputee subjects. No significant difference in performance was observed for within-day and pairs of days with eight-fold validation when using iEMG and sEMG with SSAE, whereas sEMG outperformed iEMG (p < 0.001) in between-day analysis both with two-fold and seven-fold validation schemes. The results obtained in this study imply that SSAE can significantly improve the performance of pattern recognition-based myoelectric control scheme and has the strength to extract deep information hidden in the EMG data.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] EMG-based Multi-User Hand Gesture Classification via Unsupervised Transfer Learning Using Unknown Calibration Gestures
    Shi, Haojie
    Jiang, Xinyu
    Dai, Chenyun
    Chen, Wei
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 1119 - 1131
  • [22] EMG-based 3D hand gesture prediction using transformer-encoder classification
    Mahboob, Tahira
    Chung, Min Young
    Choi, Kae Won
    ICT EXPRESS, 2023, 9 (06): : 1047 - 1052
  • [23] EMPIRICAL COPULA-BASED TEMPLATES TO RECOGNIZE SURFACE EMG SIGNALS OF HAND MOTIONS
    Ju, Zhaojie
    Zhu, Xiangyang
    Liu, Honghai
    INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2011, 8 (04) : 725 - 741
  • [24] Surface Versus Untargeted Intramuscular EMG Based Classification of Simultaneous and Dynamically Changing Movements
    Kamavuako, Ernest Nlandu
    Rosenvang, Jakob Celander
    Horup, Ronnie
    Jensen, Winnie
    Farina, Dario
    Englehart, Kevin B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (06) : 992 - 998
  • [25] A Multi-Modal Approach for Hand Motion Classification Using Surface EMG and Accelerometers
    Fougner, A.
    Scheme, E.
    Chan, A. D. C.
    Englehart, K.
    Stavdahl, O.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4247 - 4250
  • [26] Short latency hand movement classification based on surface EMG spectrogram with PCA
    Zhai, Xiaolong
    Jelfs, Beth
    Chan, Rosa H. M.
    Tin, Chung
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 327 - 330
  • [27] EMG-Based Hand Gesture Classification with Long Short-Term Memory Deep Recurrent Neural Networks
    Jabbari, Milad
    Khushaba, Rami N.
    Nazarpour, Kianoush
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3302 - 3305
  • [28] Surface EMG-Based Instantaneous Hand Gesture Recognition Using Convolutional Neural Network with the Transfer Learning Method
    Yu, Zhipeng
    Zhao, Jianghai
    Wang, Yucheng
    He, Linglong
    Wang, Shaonan
    SENSORS, 2021, 21 (07)
  • [29] Speed Based Surface EMG Classification Using Fuzzy Logic for Prosthetic Hand Control
    Ahmad, S. A.
    Ishak, A. J.
    Ali, S. H.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 121 - +
  • [30] Basic Hand Action Classification Based on Surface EMG Using Autoregressive Reflection Coefficient
    Fattah, Shaikh Anowarul
    Iqbal, Odrika
    Zahin, Saima
    Shahnaz, Celia
    Rosul, Gholam
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 1369 - 1374