Ultimate intrinsic signal-to-noise ratio in MRI

被引:175
|
作者
Ocali, O [1 ]
Atalar, E [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
关键词
SNR optimization; RF coil design; skin effect; focusing;
D O I
10.1002/mrm.1910390317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant righthand circularly polarized component of the magnetic field at the point of interest. A numerical approximation for the optimal field is found by assuming a superposition of a large number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behavior of ultimate intrinsic SNR was investigated as a function of main field strength. II: was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic field up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.
引用
收藏
页码:462 / 473
页数:12
相关论文
共 50 条
  • [21] High signal-to-noise ratio observations and the ultimate limits of precision pulsar timing
    Oslowski, S.
    van Straten, W.
    Hobbs, G. B.
    Bailes, M.
    Demorest, P.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2011, 418 (02) : 1258 - 1271
  • [22] ESTIMATION OF SIGNAL-TO-NOISE RATIO
    RAUCH, S
    IEEE TRANSACTIONS ON INFORMATION THEORY, 1969, 15 (1P1) : 166 - +
  • [23] On Signal-to-Noise Ratio Estimation
    Papic, Veljko
    Djurovic, Zeljko
    Kvascev, Goran
    Tadic, Predrag
    MELECON 2010: THE 15TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, 2010, : 160 - 165
  • [24] Enhancement of Signal-to-Noise Ratio
    Dhara, A. K.
    Journal of Statistical Physics, 87 (1-2):
  • [25] A Signal-to-Noise Ratio Enhancer
    Lu, Ning H.
    2011 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2011, : 34 - 38
  • [26] SIGNAL-TO-NOISE RATIO DEBATED
    HUNTER, JS
    QUALITY PROGRESS, 1987, 20 (05) : 7 - &
  • [27] Enhancement of signal-to-noise ratio
    Asish K. Dhara
    Journal of Statistical Physics, 1997, 87 : 251 - 271
  • [28] Enhancement of signal-to-noise ratio
    Dhara, AK
    JOURNAL OF STATISTICAL PHYSICS, 1997, 87 (1-2) : 251 - 271
  • [29] RELATIONSHIP OF SIGNAL-TO-NOISE RATIO WITH ACQUISITION PARAMETERS IN MRI FOR A GIVEN CONTRAST
    BITTOUN, J
    LEROYWILLIG, A
    IDY, I
    SAINTJALMES, H
    HALIMI, P
    SYROTA, A
    DESGREZ, A
    ANNALES DE RADIOLOGIE, 1987, 30 (01) : 5 - 13
  • [30] The ultimate intrinsic signal-to-noise ratio of loop- and dipole-like current patterns in a realistic human head model
    Pfrommer, Andreas
    Henning, Anke
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2122 - 2138