Experimental study of pressure drop and heat transfer characteristics of φ10.07 wave and wave-slit fin-tube heat exchangers with wave depth of 2 mm

被引:0
|
作者
Youn, B [1 ]
Kil, YH [1 ]
Park, HY [1 ]
Yoo, KC [1 ]
Kim, YS [1 ]
机构
[1] Samsung Elect, Air Conditioner Div, Paldal Gu, Suwon 442742, Kyungki Do, South Korea
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer and air side pressure drop for empty set 10.07 dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for various fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchanger are 21.65 mm and 25 mm respectively, and wave depth of the wave fin is 2 mm. Experiments were conducted for 1, 2 and 3 rows and 3 different fin spacings, 1.3, 1.5 and 1.7 mm. An attempt was made to demonstrate advantage of the enhanced fins over the plane fin by introducing the concept of fan power. Effect of the number of tube rows on heat transfer was discussed in connection with general mechanisms of heat transfer enhancement for fin-tube heat exchanger. Also the effect of hydrophilic coating was investigated. Lastly, correlations for Colburn j-factor and friction factor were developed.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [21] Effect of inlet air relative humidity on airside characteristics of slit fin-tube heat exchangers
    Guo, Yibo
    Du, Zhimin
    Chen, Ping
    He, Keqing
    Jin, Xinqiao
    Huagong Xuebao/CIESC Journal, 2010, 61 (SUPPL. 2): : 49 - 53
  • [22] Experimental Study on the Defrost Characteristics of an Air Source Heat Pump Unit with split Fin-tube Heat Exchangers
    Liu Chuan
    Guo Xian-Min
    Yang Bin
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [23] Experimental study on thermotechnical characteristics of fin-tube heat exchanger
    Yang, Zongshan
    Yu, Qingpo
    Ma, Depu
    Kang T'ieh/Iron and Steel (Peking), 1988, 23 (06): : 54 - 60
  • [24] Heat Transfer and Pressure Drop Characteristics of Plain Fin-and-Tube Heat Exchangers Having 5.0 mm Tubes Under Dehumidifying Condition
    Kim, Nae-Hyun
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (02)
  • [25] An experimental study on the air side heat transfer performance of the perforated fin-tube heat exchangers under the frosting conditions
    Liu, Xiaoqin
    Yu, Jianlin
    Yan, Gan
    Applied Thermal Engineering, 2020, 166
  • [26] Experimental study on heat and mass transfer characteristics for a desiccant-coated fin-tube heat exchanger
    Li, Zhang
    Michiyuki, Saikawa
    Takeshi, Fujinawa
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 641 - 651
  • [27] An experimental study on the air side heat transfer performance of the perforated fin-tube heat exchangers under the frosting conditions
    Liu, Xiaoqin
    Yu, Jianlin
    Yan, Gan
    APPLIED THERMAL ENGINEERING, 2020, 166
  • [28] Experimental investigation on the airside heat transfer and pressure drop of the fin-and-tube heat exchangers having oval tubes
    Myong, Ji-Hyun
    Choi, Byung-Nam
    Go, Min-Geon
    Kim, Nae-Hyun
    EXPERIMENTAL HEAT TRANSFER, 2022, 35 (04) : 484 - 499
  • [29] Experimental Study on Frost Height of Round Plate Fin-Tube Heat Exchangers for Mobile Heat Pumps
    Lee, Moo-Yeon
    Kim, Yongchan
    Lee, Dong-Yeon
    ENERGIES, 2012, 5 (09): : 3479 - 3491
  • [30] Effects of fin structure on heat transfer and resistance characteristics of super slit finned tube heat exchangers
    Tu Q.
    Yuan Y.
    Hu X.
    Huagong Xuebao/CIESC Journal, 2016, 67 (11): : 4615 - 4622