Modeling of fire exposure in facade fire testing

被引:20
|
作者
Anderson, J. [1 ]
Bostroem, L. [1 ]
McNamee, R. Jansson [2 ]
Milovanovic, B. [3 ]
机构
[1] RISE Safety & Transport, Fire Res, Brinellgatan 4,Box 857, S-50115 Boras, Sweden
[2] Brandskyddslaget AB, Langholmsgatan 27,Box 9196, S-10273 Stockholm, Sweden
[3] Univ Zagreb, Dept Mat, Fac Civil Engn, Kaciceva 26, Zagreb 10000, Croatia
关键词
fire; facade test; modeling; fire exposure; FDS;
D O I
10.1002/fam.2485
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a comparative simulation study on 3 large-scale facade testing methods, namely, the SP Fire 105, BS 8414-1, and the ISO 13785-2 methods, is presented. Generally good correspondence between simulations and experimental data has been found, provided that thermal properties of the facade material and heat release rates are known; however, the correspondence deviates in close proximity of the fire source. Furthermore, a statistical ensemble for evaluating the effects stemming from uncertainty in input data is used. Here, it was found using this statistical ensemble that the variability was smaller in the ISO 13785-2 compared to the BS 8414-1 method. The heat release rates (HRR) used in the simulations were adopted from measurements except for the ISO method where the information in the standard was used to approximate the HRR. A quantitative similarity between the HRR in the ISO method and the British method was found.
引用
收藏
页码:475 / 483
页数:9
相关论文
共 50 条