Legionella pneumophila contamination of hospital dishwashers

被引:8
|
作者
Yoshida, Makiko [1 ,2 ]
Furuya, Naoko [2 ]
Hosokawa, Naoto [2 ]
Kanamori, Hajime [1 ]
Kaku, Mitsuo [1 ]
Koide, Michio [3 ]
Higa, Futoshi [4 ]
Fujita, Jiro [3 ]
机构
[1] Tohoku Univ, Dept Infect Control & Lab Diagnost, Grad Sch Med, Sendai, Miyagi, Japan
[2] Kameda Med Ctr, Hosp Epidemiol & Infect Prevent Ctr, Kamogawa City, Japan
[3] Univ Ryukyus, Fac Med, Dept Infect Resp & Digest Med Control & Prevent I, Okinawa, Japan
[4] Okinawa Natl Hosp, Natl Hosp Org, Okinawa, Japan
关键词
Infection control; Tap water; Reservoir;
D O I
10.1016/j.ajic.2018.01.024
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In a tertiary hospital, Legionella spp were isolated from taps and from ward dishwashers connected to contaminated tap piping. Our investigation revealed favorable conditions for growth of Legionella, and showed that Legionella pneumophila SG6 isolates from the taps and dishwashers were all genetically identical by repetitive-element polymerase chain reaction. These results suggest that contaminated dishwashers might be a potential reservoir for the spread of Legionella in health care facilities. (C) 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:943 / 945
页数:3
相关论文
共 50 条
  • [31] AUTECOLOGY OF LEGIONELLA PNEUMOPHILA
    FLIERMANS, CB
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIES A-MEDICAL MICROBIOLOGY INFECTIOUS DISEASES VIROLOGY PARASITOLOGY, 1983, 255 (01): : 58 - 63
  • [32] ISOLATION OF LEGIONELLA PNEUMOPHILA
    GREAVES, PG
    SHARP, G
    MACRAE, AD
    LANCET, 1979, 1 (8115): : 551 - 552
  • [33] CULTURE OF LEGIONELLA PNEUMOPHILA
    RUTTER, DA
    MABER, HB
    LANCET, 1979, 1 (8118): : 723 - 724
  • [34] Pathogenicity of Legionella pneumophila
    Cianciotto, NP
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2001, 291 (05) : 331 - 343
  • [35] LEGIONELLA-PNEUMOPHILA CONTAMINATION OF A HOSPITAL HUMIDIFIER - DEMONSTRATION OF AEROSOL TRANSMISSION AND SUBSEQUENT SUBCLINICAL INFECTION IN EXPOSED GUINEA-PIGS
    ZURAVLEFF, JJ
    YU, VL
    SHONNARD, JW
    RIHS, JD
    BEST, M
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 128 (04): : 657 - 661
  • [36] Monochloramine and chlorine dioxide for controlling Legionella pneumophila contamination: biocide levels and disinfection by-product formation in hospital water networks
    Marchesi, Isabella
    Ferranti, Greta
    Bargellini, Annalisa
    Marchegiano, Patrizia
    Predieri, Guerrino
    Stout, Janet E.
    Borella, Paola
    JOURNAL OF WATER AND HEALTH, 2013, 11 (04) : 738 - 747
  • [37] LEGIONELLA-PNEUMOPHILA IN A HOSPITAL POTABLE HOT WATER-SUPPLY
    WAGENVOORT, JHT
    NIEMANDSVERDRIET, PCJ
    MONNIER, C
    MICHEL, MF
    ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1983, 49 (06): : 612 - 613
  • [38] Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system
    Lagana, Pasqualina
    Moscato, Umberto
    Poscia, Andrea
    La Milia, Daniele Ignazio
    Boccia, Stefania
    Avventuroso, Emanuela
    Delia, Santi
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2015, 22 (04) : 655 - 660
  • [39] The incidence of Legionella pneumophila:: a prospective study in a tertiary care hospital in India
    Chaudhry, R
    Dhawan, B
    Dey, AB
    TROPICAL DOCTOR, 2000, 30 (04) : 197 - 200
  • [40] PROTEINASES OF LEGIONELLA - PHENYLALANINEAMINOPEPTIDASE OF LEGIONELLA-PNEUMOPHILA
    GULNIK, SV
    YUSUPOVA, MP
    LAVRENOVA, GI
    TARTAKOVSKY, IS
    PROZOROVSKY, SV
    STEPANOV, VM
    JOURNAL OF GENERAL MICROBIOLOGY, 1986, 132 : 387 - 392