Penetration resistance and the bearing capacity of small-diameter steel piles

被引:0
|
作者
Vestberg, H. G. [1 ]
Mann, G. [1 ]
Holtz, R. D. [1 ]
机构
[1] Swedish Geotechn Inst, Linkoping, Sweden
关键词
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The objective of this study was to develop an improved relationship between the penetration resistance of small diameter steel pipe piles and their ultimate bearing capacity. Static loading tests were conducted to failure on four 50-mm diameter pipe piles that were driven with a 43 kg jack hammer to four different penetration resistances. The loads and the ultimate bearing capacities interpreted from the jack pressure gauge were 0 to 15 % higher than the capacities interpreted from load cell measurements. The tangent-line method gave loads that were more conservative than those obtained with Davisson method. In the Seattle area, the current permissible load without performing a load test is 18 kN for 50-mm pipe piles continuously driven to a penetration resistance of 25 mm per 1 min with a 43 kg jack hammer. This value was found to be very conservative. Based on our test results, the ultimate observed plunging load was about five to ten times greater than 18 kN. Other interpretation methods also gave significantly higher values.
引用
收藏
页码:2057 / 2060
页数:4
相关论文
共 50 条
  • [22] Uplift capacity of small-diameter drilled shafts from in situ tests
    Lutenegger, Alan J.
    Miller, Gerald A.
    Journal of geotechnical engineering, 1994, 120 (08): : 1362 - 1380
  • [23] The impact of grouting to the bottom of piles to the bearing capacity of large-diameter and extra piles setting into rock
    Chengzhong
    Huangjianhua
    Chengjie
    Lifeng
    Zoujianan
    SOIL MECHANICS AND GEOTECHNICAL ENGINEERING, VOL 1: ELEVENTH ASIAN REGIONAL CONFERENCE, 1999, : 281 - 285
  • [24] A new end bearing capacity equation on large diameter open-ended steel piles considering plugging effect
    Song, Sumin
    GEOTECHNICS FOR SUSTAINABLE INFRASTRUCTURE DEVELOPMENT, 2020, 62 : 113 - 119
  • [25] Study on the potential bearing capacity of long diameter and super-long piles
    Jiang, Jian-Ping
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2006, 38 (03): : 333 - 338
  • [26] Reliability-based calibration of resistance factors for static bearing capacity of driven steel pipe piles
    Kwak, Kiseok
    Kim, Kyung Jun
    Huh, Jungwon
    Lee, Ju Hyung
    Park, Jae Hyun
    CANADIAN GEOTECHNICAL JOURNAL, 2010, 47 (05) : 528 - 538
  • [27] Ultimate bearing capacity formula for large diameter belled piles based on π theorem
    Meng Gao
    Mingyao Wang
    Huihui Jiao
    Shi Yin
    Arabian Journal of Geosciences, 2021, 14 (24)
  • [28] Experimental Study on Post Grouting Bearing Capacity of Large Diameter Bored Piles
    Wang, Duanduan
    Wang, Longfei
    Zhang, Lipeng
    INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGY AND APPLICATION (ICETA 2015), 2015, 22
  • [29] Shear strengthening of steel plates using small-diameter CFRP strands
    Kazem, Hamid
    Rizkalla, Sami
    Kobayashi, Akira
    COMPOSITE STRUCTURES, 2018, 184 : 78 - 91
  • [30] Determination of bearing capacity of the precast piles by dynamic cone penetration test (DCPT)
    Zhussupbekov, A. Zh
    Alibekova, N. T.
    Morev, I. O.
    Utepov, Ye B.
    SOIL-STRUCTURE INTERACTION, UNDERGROUND STRUCTURES AND RETAINING WALLS, 2014, 4 : 242 - 247