Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography

被引:116
|
作者
Goldfarb, JW [1 ]
Edelman, RR [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
coronary vessels; MR; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.206.3.9494509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of three-dimensional (3D), single breath-hold, gadolinium-enhanced magnetic resonance (MR) coronary angiography was investigated. A 3D spoiled gradient-echo imaging technique was used to image the passage of intravenously injected paramagnetic contrast agent through the coronary vasculature in four healthy subjects. Image contrast depended solely on the injected contrast agent. 3D acquisition allowed retrospective reformation and display with maximum intensity projection and rendering algorithms.
引用
收藏
页码:830 / 834
页数:5
相关论文
共 50 条
  • [31] Extracranial atherosclerotic carotid artery disease: Evaluation of non-breath-hold three-dimensional gadolinium-enhanced MR angiography
    Slosman, F
    Stolpen, AH
    Lexa, FJ
    Schnall, MD
    Langlotz, CP
    Carpenter, JP
    Goldberg, HI
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 489 - 495
  • [32] Takayasu arteritis: Evaluation with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Shibuya, H
    Numano, F
    RADIOLOGY, 1998, 209P : 495 - 495
  • [33] Takayasu arteritis: Diagnosis with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Kobayashi, Y
    Numano, F
    Shibuya, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (05): : 481 - 487
  • [34] Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, E
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 345 - 348
  • [35] Breath-hold ultrafast three-dimensional gadolinium enhanced dual-phase MR angiography in the abdomen: First clinical results
    Gaa, JA
    Laub, GA
    Tesdal, IK
    Misri, H
    Moeckel, R
    Teubner, JK
    RADIOLOGY, 1997, 205 : 657 - 657
  • [36] Gadolinium-enhanced breath-hold three-dimensional MR angiography of the portal vein: Value of the magnetization-prepared rapid acquisition gradient-echo sequence
    Yamashita, Y
    Mitsuzaki, K
    Miyazaki, T
    Namimoto, T
    Sumi, S
    Urata, J
    Abe, Y
    Ogata, I
    Takahashi, M
    RADIOLOGY, 1996, 201 (01) : 283 - 288
  • [37] BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES
    PRINCE, MR
    NARASIMHAM, DL
    STANLEY, JC
    CHENEVERT, TL
    WILLIAMS, DM
    MARX, V
    CHO, KJ
    RADIOLOGY, 1995, 197 (03) : 785 - 792
  • [38] Assessment of renal artery stenosis: Comparison of captopril renography and gadolinium-enhanced breath-hold MR angiography
    Bongers, V
    Bakker, J
    Beutler, JJ
    Beek, FJA
    De Klerk, JMH
    CLINICAL RADIOLOGY, 2000, 55 (05) : 346 - 352
  • [39] Gadolinium-enhanced breath-hold three-dimensional time-of-flight MR angiography of the abdominal and pelvic vessels: The value of ultrafast MP-RAGE sequences
    Yamashita, Y
    Mitsuzaki, K
    Tang, Y
    Namimoto, T
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 623 - 628
  • [40] Detection of hepatocellular carcinoma: comparison of ferumoxides-enhanced and gadolinium-enhanced dynamic three-dimensional volume interpolated breath-hold MR imaging
    Hyo-Sung Kwak
    Jeong-Min Lee
    Young-Kon Kim
    Young Hwan Lee
    Chong-Soo Kim
    European Radiology, 2005, 15 : 140 - 147