Acquiring a four-dimensional computed tomography dataset using an external respiratory signal

被引:549
|
作者
Vedam, SS
Keall, PJ
Kini, VR
Mostafavi, H
Shukla, HP
Mohan, R
机构
[1] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Philips Med Syst, Highland Hts, OH USA
[5] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 01期
关键词
D O I
10.1088/0031-9155/48/1/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four-dimensional (4D) methods strive to achieve highly conformal radiotherapy, particularly for lung and breast tumours, in the presence of respiratory-induced motion of tumours and normal tissues. Four-dimensional radiotherapy accounts for respiratory motion during imaging, planning and radiation delivery, and requires a 4D CT image in which the internal anatomy motion as a function of the respiratory cycle can be quantified. The aims of our research were (a) to develop a method to acquire 4D CT images from a spiral CT scan using an external respiratory signal and (b) to examine the potential utility of 4D CT imaging. A commercially available respiratory motion monitoring system provided an 'external' tracking signal of the patient's breathing. Simultaneous recording of a TTL 'X-Ray ON' signal from the CT scanner indicated the start time of CT image acquisition, thus facilitating time stamping of all subsequent images. An over-sampled spiral CT scan was acquired using a pitch of 0.5 and scanner rotation time of 1.5 s. Each image from such a scan was sorted into an image bin that corresponded with the phase of the respiratory cycle in which the image was acquired. The complete set of such image bins accumulated over a respiratory cycle constitutes a 4D CT dataset. Four-dimensional CT datasets of a mechanical oscillator phantom and a patient undergoing lung radiotherapy were acquired. Motion artefacts were significantly reduced in the images in the 4D CT dataset compared to the three-dimensional (3D) images, for which respiratory motion was not accounted. Accounting for respiratory motion using 4D CT imaging is feasible and yields images with less distortion than 3D images. 4D images also contain respiratory motion information not available in a 3D CT image.
引用
收藏
页码:45 / 62
页数:18
相关论文
共 50 条
  • [41] Four-dimensional Computed Tomography for Preoperative Localization of Parathyroid Adenomas
    Zeina, Abdel-Rauf
    Nakar, Helit
    Reindorp, Nadir
    Nachtigal, Alicia
    Krausz, Michael M.
    Ashkenazi, Itamar
    Shapira-Rootman, Mika
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (04): : 216 - 220
  • [42] Four-dimensional computed tomography and detection of dynamic capitate subluxation
    Repse, Stephen E.
    Amis, Benjamin
    Troupis, John M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (03) : 331 - 335
  • [43] A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion
    Hallman, Joshua L.
    Mori, Shinichiro
    Sharp, Gregory C.
    Lu, Hsiao-Ming
    Hong, Theodore S.
    Chen, George T. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : 435 - 441
  • [44] Motion artifact detection in four-dimensional computed tomography images
    Bouilhol, G.
    Ayadi, M.
    Pinho, R.
    Rit, S.
    Sarrut, D.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [45] Evaluation of stuck mechanical valve with four-dimensional computed tomography
    Numata, Satoshi
    Tsutsumi, Yasushi
    Ohashi, Hirokazu
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (03) : 594 - 594
  • [46] Dynamic Four-Dimensional Computed Tomography Angiography for Neurovascular Pathologies
    Alnemari, Ahmed
    Mansour, Tarek R.
    Bazerbashi, Mohamad
    Buehler, Mark
    Schroeder, Jason
    Gaudin, Daniel
    WORLD NEUROSURGERY, 2017, 105 : 1034.e11 - 1034.e18
  • [47] Dynamic ventilation imaging from four-dimensional computed tomography
    Guerrero, T
    Sanders, K
    Castillo, E
    Zhang, Y
    Bidaut, L
    Pan, TS
    Komaki, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 777 - 791
  • [48] Four-dimensional computed tomography: Image formation and clinical protocol
    Rietzel, E
    Pan, TS
    Chen, GTY
    MEDICAL PHYSICS, 2005, 32 (04) : 874 - 889
  • [49] Commissioning a four-dimensional computed tomography system for clinical implementation
    Sasaki, D. K.
    Ingleby, H.
    Venkataraman, S.
    MEDICAL PHYSICS, 2009, 36 (09) : 4319 - 4320
  • [50] Quantifying in vivo scaphoid, lunate, and capitate kinematics using four-dimensional computed tomography
    Brinkhorst, Michelle
    Foumani, Mahyar
    van Rosmalen, Joost
    Selles, Ruud
    Hovius, Steven
    Strackee, Simon
    Streekstra, Geert
    SKELETAL RADIOLOGY, 2021, 50 (02) : 351 - 359