Acquiring a four-dimensional computed tomography dataset using an external respiratory signal

被引:549
|
作者
Vedam, SS
Keall, PJ
Kini, VR
Mostafavi, H
Shukla, HP
Mohan, R
机构
[1] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Philips Med Syst, Highland Hts, OH USA
[5] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 01期
关键词
D O I
10.1088/0031-9155/48/1/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four-dimensional (4D) methods strive to achieve highly conformal radiotherapy, particularly for lung and breast tumours, in the presence of respiratory-induced motion of tumours and normal tissues. Four-dimensional radiotherapy accounts for respiratory motion during imaging, planning and radiation delivery, and requires a 4D CT image in which the internal anatomy motion as a function of the respiratory cycle can be quantified. The aims of our research were (a) to develop a method to acquire 4D CT images from a spiral CT scan using an external respiratory signal and (b) to examine the potential utility of 4D CT imaging. A commercially available respiratory motion monitoring system provided an 'external' tracking signal of the patient's breathing. Simultaneous recording of a TTL 'X-Ray ON' signal from the CT scanner indicated the start time of CT image acquisition, thus facilitating time stamping of all subsequent images. An over-sampled spiral CT scan was acquired using a pitch of 0.5 and scanner rotation time of 1.5 s. Each image from such a scan was sorted into an image bin that corresponded with the phase of the respiratory cycle in which the image was acquired. The complete set of such image bins accumulated over a respiratory cycle constitutes a 4D CT dataset. Four-dimensional CT datasets of a mechanical oscillator phantom and a patient undergoing lung radiotherapy were acquired. Motion artefacts were significantly reduced in the images in the 4D CT dataset compared to the three-dimensional (3D) images, for which respiratory motion was not accounted. Accounting for respiratory motion using 4D CT imaging is feasible and yields images with less distortion than 3D images. 4D images also contain respiratory motion information not available in a 3D CT image.
引用
收藏
页码:45 / 62
页数:18
相关论文
共 50 条
  • [1] Determination of respiratory motion for distal esophagus cancer using four-dimensional computed tomography
    Yaremko, Brian P.
    Guerrero, Thomas M.
    McAleer, Mary F.
    Bucci, M. Kara
    Noyola-Martinez, Josue
    Nguyen, Linda T.
    Balter, Peter A.
    Guerra, Rudy
    Komaki, Ritsuko
    Liao, Zhongxing
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 145 - 153
  • [2] An algorithm for automatic determination of the respiratory phases in four-dimensional computed tomography
    Kleshneva, T.
    Muzik, J.
    Alber, M.
    Phys. Med. Biol., 1600, 16 (N269-N276):
  • [3] An algorithm for automatic determination of the respiratory phases in four-dimensional computed tomography
    Kleshneva, T.
    Muzik, J.
    Alber, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16): : N269 - N276
  • [4] Respiratory motion of adrenal gland metastases: Analyses using four-dimensional computed tomography images
    Chen, Bing
    Hu, Yong
    Liu, Jin
    Cao, An-Ning
    Ye, Lu-Xi
    Zeng, Zhao-Chong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 : 54 - 58
  • [5] Metrics for assessment of reproducibility of respiratory motion for four-dimensional computed tomography imaging
    Bivens, Whitney
    Starkschall, George
    Nelson, Christopher
    MEDICAL PHYSICS, 2006, 33 (06) : 2042 - 2042
  • [6] Effect of respiratory cycle irregularities on image quality in four-dimensional computed tomography
    Thorndyke, B
    Xing, L
    Graves, E
    Loo, BW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S506 - S506
  • [7] Algorithm for automatic offline determination of the respiratory phases in four-dimensional computed tomography
    Kleshneva, T.
    Muzik, J.
    Alber, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S407 - S407
  • [8] Quantitation of the four-dimensional computed tomography process
    Lu, W
    Parikh, P
    El Naqa, I
    Nystrom, M
    Hubenschmidt, J
    Wahab, S
    Singh, A
    Christensen, G
    Mutic, S
    Bradley, J
    Low, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1780 - 1780
  • [9] Quantitation of the four-dimensional computed tomography process
    Lu, W
    Parikh, P
    ElNaqa, I
    Nystrom, M
    Hubenschmidt, J
    Wahab, S
    Mutic, S
    Singh, A
    Christensen, G
    Bradley, JD
    Low, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S286 - S286
  • [10] Four-dimensional computed tomography: musculoskeletal applications
    Wong, Murray T.
    Wiens, Charmaine
    Kuczynski, Michael
    Manske, Sarah
    Schneider, Prism S.
    CANADIAN JOURNAL OF SURGERY, 2022, 65 (03) : E388 - E393