Buckling behavior and strength of thin-walled stiffened trapezoidal CFS under flexural bending

被引:8
|
作者
Santos Franco, Juarez Moara [1 ,2 ]
Batista, Eduardo de Miranda [1 ,3 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, Ilha Fundao, Bloco 1 Sala I-216,POB 68506, BR-21945970 Rio de Janeiro, RJ, Brazil
[2] Univ Fed Rural Rio de Janeiro, Architecture & Urbanism Dept, Rio De Janeiro, Brazil
[3] Univ Fed Rio de Janeiro, COPPE, Civil Engn Program, Rio De Janeiro, Brazil
关键词
Steel roof structure; Cold-formed profiled sheeting; Stiffened cold-formed section; Buckling analysis; Shape grammar; Bending moment strength; DESIGN;
D O I
10.1016/j.tws.2016.11.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold formed steel members are widely applied in light roofing systems, mainly with trussed structural solutions. Developed from thin steel sheets (usually of around one millimeter thickness) stiffened trapezoidal CFS can be considered as an alternative for large span roofing, allowing the assembling of an orthotropic roofing system. In order to improve its flexural buckling behavior, these thin-walled sections must be designed with intermediate stiffeners and quite large possibilities can be achieved in order to (i) improve the cross-section strength under bending moment, (ii) simplify and improve the stiffeners arrangement, (iii) maximize the roof covering width, (iv) develop the roofing system for long span bridging and (v) design with as thin as possible steel sheets. Considering all these conditions, the general cross-section shape can be infinitively modified adopting different stiffener geometries, dimensions, distribution, as well as combining distinct stiffeners along the cross-section. Rational systematic choices and buckling results allowed identifying the "best" solutions, taking advantage of the shape grammar contribution combined with finite strip method buckling analysis. The obtained results revealed the key geometric parameters that must be considered to perform effective improvement of roofing trapezoidal CFS.
引用
收藏
页码:268 / 281
页数:14
相关论文
共 50 条
  • [21] Buckling of Stiffened Thin-Walled Truncated Cones Subjected to External Pressure
    M. E. Barkey
    M. C. Turgeon
    T. Varun Nare
    Experimental Mechanics, 2008, 48 : 281 - 291
  • [22] Buckling of stiffened thin-walled truncated cones subjected to external pressure
    Barkey, M. E.
    Turgeon, M. C.
    Nare, T. Varun
    EXPERIMENTAL MECHANICS, 2008, 48 (03) : 281 - 291
  • [23] BUCKLING STRENGTH OF THIN-WALLED STRUCTURES WITH FOLDED AND CURVED GROOVES IN CONSIDERATION OF THE CURVATURES OF CORNERS AND STIFFENED PARTS
    Hoshide, Koki
    Sogabe, Yuji
    Ohga, Mitao
    Shigematsu, Tsunemi
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [24] POST-BUCKLING STRENGTH OF THIN-WALLED MEMBERS
    LEE, HP
    HARRIS, PJ
    COMPUTERS & STRUCTURES, 1979, 10 (04) : 689 - 702
  • [25] Buckling, strength and failure mechanics of thin-walled structures
    Zaras, J
    Kowal-Michalska, K
    Rhodes, J
    THIN-WALLED STRUCTURES, 2003, 41 (2-3) : 89 - 90
  • [26] Buckling of Thin-Walled Long Steel Cylinders Subjected to Bending
    Houliara, Sotiria
    Karamanos, Spyros A.
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [27] IMPACT STRENGTH OF THIN-WALLED COMPOSITE STRUCTURES UNDER COMBINED BENDING AND TORSION
    MIZUKAWA, K
    FUJII, T
    ITAMI, K
    OSAKA, K
    COMPOSITE STRUCTURES, 1985, 4 (02) : 179 - 192
  • [28] Buckling behavior of built-up thin-walled I-beams with trapezoidal flanged cores
    Plust, Michal
    Paczos, Piotr
    Kedzia, Piotr
    ENGINEERING STRUCTURES, 2025, 331
  • [29] THE ELASTIC BUCKLING BEHAVIOR OF THIN-WALLED STEEL CYLINDRICAL SHELL WITH FOLDED, CURVED GROOVES AND STIFFENED PLATES
    Hoshide, Koki
    Sogabe, Yuji
    Ohga, Mitao
    Shigematsu, Tsunemi
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [30] Buckling and post-buckling of long pressurized elastic thin-walled tubes under in-plane bending
    Houliara, S.
    Karamanos, S. A.
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2006, 41 (04) : 491 - 511