Improved quantification of fluorescence in 3-D In a realistic mouse phantom

被引:2
|
作者
Srinivasan, Subhadra [1 ]
Pogue, Brian W. [1 ]
Davis, Scott [1 ]
Leblond, Frederic [2 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] ART Adv Res Technol Inc, Saint Laurent, PQ H4S 2A4, Canada
关键词
fluorescence; Image reconstruction; small animal imaging;
D O I
10.1117/12.698636
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advanced imaging systems and theoretical models have been developed to quantify fluorescence, and this theoretical framework involves numerical-based solutions of a set of coupled diffusion equations. One key to advancing this modality is the extension of the imaging into realistic tissue geometries, which can be dynamically updated from data from other high resolution modalities. Here we explore the quantification of fluorescence in a three-dimensional (3-D) mouse phantom tagged with heterogeneous optical properties. A finite element model for the diffusion equation was used to approximate light propagation along with Newton's method for image reconstruction, to recover 3-D images of fluorescent yield. Using measurements generated on a brain tumor in a mouse with 2% noise, our results show that only 11.4% of the expected fluorescent yield could be recovered without any prior knowledge about the spatial structure of the domain. Using a parameter reduction scheme based upon prior spatial information of the location and size of the tumor, 100% of the expected value could be estimated. These preliminary results indicate that image guided fluorescence spectroscopy has the ability to provide accurate fluorescence recovery, whereas diffuse imaging based recovery is limited in the ability to quantify.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] SOLVING CRIMES WITH 3-D FLUORESCENCE SPECTROSCOPY
    SIEGEL, JA
    ANALYTICAL CHEMISTRY, 1985, 57 (08) : A934 - &
  • [32] Guidelines for an improved quality of experience in 3-D TV and 3-D mobile displays
    Xu, Di
    Coria, Lino E.
    Nasiopoulos, Panos
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2012, 20 (07) : 397 - 407
  • [33] New 3-D Fluorescence Spectral Indices for Multiple Pigment Inversions of Plant Leaves via 3-D Fluorescence Spectra
    Tian, Shoupeng
    Zhang, Yao
    Wang, Jiaoru
    Zhang, Rongxu
    Wu, Weizhi
    He, Yadong
    Wu, Xiaobin
    Sun, Wei
    Li, Dong
    Xiao, Yixin
    Wang, Fumin
    REMOTE SENSING, 2024, 16 (11)
  • [34] 3-D Quantification of the Aortic Arch Morphology in 3-D CTA Data for Endovascular Aortic Repair
    Woerz, Stefan
    von Tengg-Kobligk, Hendrik
    Henninger, Verena
    Rengier, Fabian
    Schumacher, Hardy
    Boeckler, Dittmar
    Kauczor, Hans-Ulrich
    Rohr, Karl
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (10) : 2359 - 2368
  • [35] Novel 3-D video for quantification of facial movement
    Mehta, Ritvik P.
    Zhang, Song
    Hadlock, Tessa A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2008, 138 (04) : 468 - 472
  • [36] Quantification of biogenic 3-D structures in marine sediments
    Rosenberg, R
    Ringdahl, K
    JOURNAL OF EXPERIMENTAL MARINE BIOLOGY AND ECOLOGY, 2005, 326 (01) : 67 - 76
  • [37] 3-D Quantification of Filopodia in Motile Cancer Cells
    Castilla, Carlos
    Maska, Martin
    Sorokin, Dmitry V.
    Meijering, Erik
    Ortiz-de-Solorzano, Carlos
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (03) : 862 - 872
  • [38] A vision-based 3-D mouse
    Nesi, P
    DelBimbo, A
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER STUDIES, 1996, 44 (01) : 73 - 91
  • [39] 3-D reconstruction of the embryonic mouse viscerocranium
    Sperber, SM
    Guttman, GD
    FASEB JOURNAL, 1998, 12 (05): : A946 - A946
  • [40] Embryonic insight - Mouse histology in 3-D
    Josephson, Julian
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2006, 114 (10) : A596 - A599