Development of the Soft X-ray AGM-AGS RIXS beamline at the Taiwan Photon Source

被引:19
|
作者
Singh, A. [1 ]
Huang, H. Y. [1 ]
Chu, Y. Y. [1 ]
Hua, C. Y. [1 ]
Lin, S. W. [1 ]
Fung, H. S. [1 ]
Shiu, H. W. [1 ]
Chang, J. [1 ]
Li, J. H. [2 ]
Okamoto, J. [1 ]
Chiu, C. C. [1 ]
Chang, C. H. [1 ]
Wu, W. B. [1 ]
Perng, S. Y. [1 ]
Chung, S. C. [1 ]
Kao, K. Y. [1 ]
Yeh, S. C. [1 ]
Chao, H. Y. [1 ]
Chen, J. H. [1 ]
Huang, D. J. [1 ,2 ]
Chen, C. T. [1 ]
机构
[1] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[2] Natl Tsing Hua Univ, Dept Phys, Hsinchu 30013, Taiwan
关键词
soft X-ray beamline; soft X-ray optics; grating monochromator; active grating; resonant inelastic X-ray scattering; soft X-ray spectra;
D O I
10.1107/S1600577521002897
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the development of a high-resolution and highly efficient beamline for soft X-ray resonant inelastic X-ray scattering (RIXS) located at the Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations, as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angles over a wide range. Several high-precision instruments developed in-house for this beamline are described briefly. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power of 4.2 x 10(4), while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impact of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, i.e. La2-xSrxCuO4. The measurements reveal the A(1g) buckling phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge-density waves.
引用
收藏
页码:977 / 986
页数:10
相关论文
共 50 条
  • [41] Fundamental techniques for high photon energy stability of a modern soft x-ray beamline
    Senba, Yasunori
    Ohashi, Haruhiko
    Kishimoto, Hikaru
    Miura, Takanori
    Goto, Shunji
    Shin, Shik
    Shintake, Tsumoru
    Ishikawa, Tetsuya
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 718 - +
  • [42] X-ray Beam Position Monitors and their Usage at the Taiwan Photon Source
    Huang, Chih-Hsien
    Wu, Chun-Yi
    Chiu, Pei-Chen
    Cheng, Yung-Sen
    Liao, Chih-Yu
    Hu, Kuo-Hwa
    Hsu, Kuo-Tung
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [43] The new X-ray absorption fine-structure beamline with sub-second time resolution at the Taiwan Photon Source
    Pao, Chih Wen
    Chen, Jeng Lung
    Lee, Jyh Fu
    Tsai, Meng Che
    Huang, Chi Yi
    Chiu, Chao Chih
    Chang, Chao Yu
    Chiang, Liang Chih
    Huang, Yu Shan
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 930 - 938
  • [44] Development of Superconducting Nanostrip X-Ray Detector for High-Resolution Resonant Inelastic Soft X-Ray Scattering (RIXS)
    Watanabe, Chiharu
    Ukibe, Masahiro
    Zen, Nobuyuki
    Fujii, Go
    Makise, Kazumasa
    Ohkubo, Masataka
    Lee, Te-Hui
    Huang, Di-Jing
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [45] X-ray Optics Testing Beamline 1-BM at the Advanced Photon Source
    Macrander, Albert
    Erdmann, Mark
    Kujala, Naresh
    Stoupin, Stanislav
    Marathe, Shashidhara
    Shi, Xianbo
    Wojcik, Michael
    Nocher, Dan
    Conley, Raymond
    Sullivan, Joseph
    Goetze, Kurt
    Maser, Jorg
    Assoufid, Lahsen
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [46] X-ray interferometry development at the advanced photon source
    Fezzaa, K
    Lee, WK
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 167 - 173
  • [47] Dedicated full-field X-ray imaging beamline at Advanced Photon Source
    Shen, Qun
    Lee, Wah-Keat
    Fezzaa, Kamel
    Chu, Yong S.
    De Carlo, Francesco
    Jemian, Peter
    Ilavsky, Jan
    Erdmann, Mark
    Long, Gabrielle G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (01): : 77 - 79
  • [48] Effect of x-ray beamline optics on x-ray photon correlation spectroscopy experiments
    Sandy, A. R.
    Evans-Lutterodt, K.
    Fezzaa, K.
    Kim, S.
    Narayanan, S.
    Sprung, M.
    Stein, A.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705
  • [49] Projection X-ray Topography System at 1-BM X-ray Optics Test Beamline at the Advanced Photon Source
    Stoupin, Stanislav
    Raghothamachar, Balaji
    Dudley, Michael
    Liu, Zunping
    Trakhtenberg, Emil
    Lang, Keenan
    Goetze, Kurt
    Sullivan, Joseph
    Macrander, Albert
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [50] Development of soft x-ray laser irradiation beamline for ablation and damage study
    Ishino, Masahiko
    Dinh, Thanh-Hung
    Hasegawa, Noboru
    Sakaue, Kazuyuki
    Higashiguchi, Takeshi
    Satoshi, Ichimaru
    Hatayama, Masatoshi
    Washio, Masakazu
    Nishikino, Masaharu
    LASER APPLICATIONS IN MICROELECTRONIC AND OPTOELECTRONIC MANUFACTURING (LAMOM) XXIV, 2019, 10905