Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

被引:25
|
作者
Chan, Heang-Ping [1 ]
Wu, Yi-Ta [1 ]
Sahiner, Berkman [1 ]
Wei, Jun [1 ]
Helvie, Mark A. [1 ]
Zhang, Yiheng [1 ]
Moore, Richard H. [2 ]
Kopans, Daniel B. [2 ]
Hadjiiski, Lubomir [1 ]
Way, Ted [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
digital breast tomosynthesis; computer-aided diagnosis; mass; SART; COMPUTER-AIDED DIAGNOSIS; RADIOLOGISTS CHARACTERIZATION; MAMMOGRAPHIC MASSES; CLASSIFICATION; IMPROVEMENT; PERFORMANCE; OBSERVER; CANCER;
D O I
10.1118/1.3432570
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A(z)) under the receiver operating characteristic curve. Results: The test Az values from the DBT-slice approach ranged from 0.87 +/- 0.03 to 0.93 +/- 0.02, while those from the PV approach ranged from 0.78 +/- 0.04 to 0.84 +/- 0.04. The highest test Az of 0.93 +/- 0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test Az of 0.84 +/- 0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images. (c) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3432570]
引用
收藏
页码:3576 / 3586
页数:11
相关论文
共 50 条
  • [21] Dose Reduction in Digital Breast Tomosynthesis (DBT) Screening using Synthetically Reconstructed Projection Images: An Observer Performance Study
    Gur, David
    Zuley, Margarita L.
    Anello, Maria I.
    Rathfon, Grace Y.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Wallace, Luisa
    Lu, Amy
    Bandos, Andriy I.
    ACADEMIC RADIOLOGY, 2012, 19 (02) : 166 - 171
  • [22] Breast cancer detection using machine learning in digital mammography and breast tomosynthesis: A systematic review
    A. Malliori
    N. Pallikarakis
    Health and Technology, 2022, 12 : 893 - 910
  • [23] Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis
    Wei, Jun
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Helvie, Mark A.
    Lu, Yao
    Zhou, Chuan
    Samala, Ravi
    MEDICAL PHYSICS, 2014, 41 (04)
  • [24] Comparison of breast percent density estimated from digital mammograms and central reconstructed tomosynthesis slice images
    Bakic, Predrag R.
    Kontos, Despina
    Troxel, Andrea B.
    Maidment, Andrew
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 674 - +
  • [25] Wiener Filter for Filtered Back Projection in Digital Breast Tomosynthesis
    Wang, Xinying
    Mainprize, James G.
    Wu, Gang
    Yaffe, Martin J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [26] A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data
    Young, Stefano
    Bakic, Predrag R.
    Myers, Kyle J.
    Jennings, Robert J.
    Park, Subok
    MEDICAL PHYSICS, 2013, 40 (05)
  • [27] Usefulness of digital breast tomosynthesis for non-calcified benign breast masses
    Yamamoto, Nobuko
    Yoshizako, Takeshi
    Yoshida, Rika
    Ando, Shinji
    Nakamura, Megumi
    Yoshikawa, Kazuaki
    Itakura, Masayuki
    Kitagaki, Hajime
    CLINICAL IMAGING, 2019, 54 : 84 - 90
  • [28] Stereoscopic vs. monoscopic detection of masses on breast tomosynthesis projection images
    Muralidhar, Gautam S.
    Ganapathi, Tejaswini
    Bovik, Alan C.
    Markey, Mia K.
    Haygood, Tamara Miner
    Stephens, Tanya W.
    Whitman, Gary J.
    MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318
  • [29] A deep learning classifier for digital breast tomosynthesis
    Ricciardi, R.
    Mettivier, G.
    Staffa, M.
    Sarno, A.
    Acampora, G.
    Minelli, S.
    Santoro, A.
    Antignani, E.
    Orientale, A.
    Pilotti, I. A. M.
    Santangelo, V
    D'Andria, P.
    Russo, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 83 : 184 - 193
  • [30] Digital Breast Tomosynthesis: Radiologist Learning Curve
    Miglioretti, Diana L.
    Abraham, Linn
    Lee, Christoph L.
    Buist, Diana S. M.
    Herschorn, Sally D.
    Sprague, Brian L.
    Henderson, Louise M.
    Tosteson, Anna N. A.
    Kerlikowske, Karla
    RADIOLOGY, 2019, 291 (01) : 33 - 41