共 50 条
Proficiency Survey-Based Evaluation of Clinical Total and Allergen-Specific IgE Assay Performance
被引:2
|作者:
Hamilton, Robert G.
[1
,2
]
机构:
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Johns Hopkins Asthma & Allergy Ctr, Baltimore, MD 21224 USA
[2] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21224 USA
关键词:
IMMUNOGLOBULIN-E LEVELS;
COWS MILK ALLERGY;
FOOD CHALLENGES;
ACCURACY;
DIAGNOSIS;
CHILDREN;
ANTIBODIES;
SERUM;
D O I:
暂无
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Context.-The diagnostic algorithm for human allergic disease involves confirmation of sensitization by detection of allergen-specific immunoglobulin E (IgE) antibody in individuals suspected of having allergic disease because of a history of allergic symptoms after known allergen exposure. Previous studies showed wide disparity among clinically reported allergen-specific IgE levels from different serologic assays. Objective.-To validate the relative analytic performance (sensitivity, interassay reproducibility, linearity/parallelism, intermethod agreement) of clinically used total and allergen-specific IgE assays by using College of American Pathologists' Diagnostic Allergy "SE'' Proficiency Survey data. Design.-Data from 2 SE survey cycles were used to assess relative analytic performance of the ImmunoCAP (Phadia), Immulite (Siemens Healthcare-Diagnostics), and HYTEC 288 (HYCOR-Agilent Technologies) total and allergen-specific IgE assays. In each cycle, 2 recalcified plasma pools from atopic donors were diluted twice with IgE-negative serum and evaluated in approximately 200 federally certified clinical laboratories for total IgE and IgE antibody to 5 allergen specificities. Statistical analysis evaluated analytic sensitivity, linearity, reproducibility, and intermethod agreement. Results.-Interlaboratory intramethod, intermethod, and interdilution agreement of all 6 clinically used total serum IgE assays were excellent, with coefficients of variation (CVs) below 15%. Interlaboratory intramethod, and interdilution agreement of 3 clinically used allergen-specific IgE assays were also excellent with CVs below 15%. However, intermethod CVs identified between-assay disagreement greater than 20% in 80% of allergen-specific IgE measurements. Allergen reagents and patients' immune response heterogeneity are suggested probable causes. Conclusions.-Clinical total and allergen-specific IgE assays display excellent analytic sensitivity, precision, reproducibility, and linearity. Marked variability in quantitative estimates of allergen-specific IgE from clinically used automated immunoassays is a concern that may be ameliorated with component allergen use. (Arch Pathol Lab Med. 2010;134:975-982)
引用
收藏
页码:975 / 982
页数:8
相关论文