Comparison of Two Minimally Invasive Osteosynthesis Techniques for Radial Head Fractures in Paediatric Patients

被引:0
|
作者
Marek, O. [1 ]
Turek, J. [1 ]
Seehofnerova, A. [2 ]
Planka, L. [1 ]
Stichhauer, R. [3 ]
机构
[1] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Chirurg Ortopedie Traumatol, Brno, Czech Republic
[2] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Radiol, Brno, Czech Republic
[3] Univ Karlovy, Lekarska Fak, Fak Nemocnice Hradec Kralove, Oddeleni Detske Chirurg & Traumatol, Hradec Kralove, Czech Republic
关键词
minimally invasive osteosynthesis; radial head; fracture; child; NECK FRACTURES; CHILDREN; REDUCTION; MANAGEMENT; FIXATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY Radial head fractures in paediatric patients account for 5-19% of all elbow injuries and approximately 1% of all fractures in children. Non-displaced fractures are treated with plaster cast fixation. If the fracture is displaced, we proceed to closed reduction, or to osteosynthesis in case of unstable fragments. If closed reduction fails, we opt for open reduction and osteosynthesis. The prospective randomised clinical study aims to compare the two methods of minimally invasive osteosynthesis using the pre-bent Kirschner wire or Prevot nail and to identify differences between them. MATERIAL AND METHODS The prospective randomised clinical study was conducted in 2015-2019. The final cohort included 32 patients who met the inclusion criteria. The patients in whom other osteosynthesis implants had been used or in whom open reduction had to be performed were excluded from the study. Also excluded were the patients with serious concomitant injuries of elbow. For patients included in the cohort, demographic data, precise evaluation of the displacement and location of the fracture as well as the duration of plaster cast fixation and osteosynthesis implants used were recorded. In the clinical part, the methods were compared based on the achievement of full range of motion in dependence on the degree of original displacement, use of osteosynthesis implant, and occurrence of early and delayed complications. Clinical and radiological outcomes were compared. In both types of minimally invasive osteosynthesis, Metaizeau surgical technique was used. RESULTS Based on the clinical trial criteria, 26 (81%) excellent, 4 (13%) good and 2 (6%) acceptable outcomes were achieved. In 3 cases the loss of rotation was up to 20 degrees, in 1 case the loss of flexion was up to 10 degrees. In one patient the loss of flexion was 15 degrees and rotation up to 30 degrees. In another patient the loss of rotation was up to 40 degrees. The radiological assessment showed 14 (44%) excellent outcomes, 15 good (47%) and 3 (9%) acceptable outcomes. The statistical analysis of both the groups of the cohort using non-parametric tests revealed no statistically significant differences in individual demographic parameters. The comparisons of both types of osteosynthesis in dependence on the degree of displacement by non-parametric Fisher's exact test showed no statistically significant difference in the radiologic or clinical results. The only statistically significant difference was observed in the duration of metal implant placement. DISCUSSION Comparable studies report excellent or good clinical outcomes in 80-95% of cases (1,13,16). In our cohort, excellent or good clinical outcomes were achieved in 30 patients (94%). In two patients, in whom Prevot nail was used, the outcomes were acceptable. Nonetheless, this fact did not result in any statistical significance when comparing the two methods separately or in comparisons based on the degree of displacement. CONCLUSIONS The comparison of the two methods of minimally invasive osteosynthesis revealed no statistically significant difference, namely not even when both the methods were compared based on the degree of displacement. When Kirschner wire is used, the possibility to remove the metal implant in the outpatient setting is considered to be an advantage. The drawback consists in potential penetration of the sharp Kirschner wire in the radiocapitellar joint, which we did not encounter when the second technique of osteosynthesis was used. The advantage of Prevot nail includes a lower risk of pin-tract infection.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [21] Minimally invasive plate osteosynthesis for distal radius fractures
    Xu-ming Wei
    Zhen-zhong Sun
    Yong-jun Rui
    Xiao-Jun Song
    Indian Journal of Orthopaedics, 2014, 48 : 20 - 24
  • [22] Minimally invasive plate osteosynthesis for humerus diaphyseal fractures
    Shetty, M. Shantharam
    Kumar, M. Ajith
    Sujay, K. T.
    Kini, Abhishek R.
    Kiran, Kanthi G.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (06) : 520 - 526
  • [23] Minimally invasive plate osteosynthesis for distal radius fractures
    Wei, Xu-ming
    Sun, Zhen-zhong
    Rui, Yong-jun
    Song, Xiao-Jun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) : 20 - 24
  • [24] Fractures of the distal tibia: minimally invasive plate osteosynthesis
    Redfern, DJ
    Syed, SU
    Davies, SJM
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (06): : 615 - 620
  • [25] Minimally invasive plate osteosynthesis for distal tibial fractures
    Devkota, Pramod
    Khan, Javed A.
    Shrestha, Suman K.
    Acharya, Balakrishnan M.
    Pradhan, Nabeesman S.
    Mainali, Laxmi P.
    Khadka, Padam B.
    Manandhar, Hemanta K.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03): : 299 - 303
  • [26] Minimally invasive plate osteosynthesis for proximal humeral fractures
    Koljonen, Paul Aarne
    Fang, Christian
    Lau, Tak Wing
    Leung, Frankie
    Cheung, Nigel W. K.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 160 - 163
  • [27] Minimally invasive plate osteosynthesis for humerus diaphyseal fractures
    M. Shantharam Shetty
    M. Ajith Kumar
    K. T. Sujay
    Abhishek R. Kini
    G. Kiran Kanthi
    Indian Journal of Orthopaedics, 2011, 45 : 520 - 526
  • [28] Minimally invasive plate osteosynthesis for tibial plateau fractures
    Raza, Hasnain
    Hashmi, Pervaiz
    Abbas, Kashif
    Hafeez, Kamran
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (01) : 42 - 47
  • [29] Comparison of a minimally invasive osteosynthesis technique with conventional open surgery for transverse patellar fractures
    Yao Li-Wei
    Mao Hai-Jiao
    Dong Wen-Wei
    Wu Ze-Ting
    Liu Qing
    中华创伤杂志英文版, 2023, 26 (05)
  • [30] Minimally invasive plate osteosynthesis of distal tibial fractures: a comparison of medial and lateral plating
    Shon, Oog-jin
    Park, Chul-hyun
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2012, 17 (05) : 562 - 566