Customized Radiofrequency Phased-Array Coil Combining Transmit-Only, Receive-Only, and Transmit/Receive Coils for Magnetic Resonance Imaging of Visual Cortex at 7 Tesla

被引:2
|
作者
Kim, Hyeong-Seop [1 ,2 ]
Song, Byung-Pan [1 ,2 ]
Kim, Royoung [2 ,3 ]
Choi, Woo-Chul [4 ]
Kim, Donghyuk [5 ]
Shim, Won Mok [1 ,2 ,3 ]
Kim, Kyoung-Nam [6 ]
Lee, Seung-Kyun [1 ,2 ,3 ,7 ]
机构
[1] Sungkyunkwan Univ, Dept Intelligent Precis Healthcare Convergence, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon 16419, South Korea
[3] Sungkyunkwan Univ, Dept Biomed Engn, Suwon 16419, South Korea
[4] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon 34141, South Korea
[5] Gachon Univ, Dept Hlth Sci & Technol, GAIHST, Incheon 21999, South Korea
[6] Gachon Univ, Dept Biomed Engn, Incheon 21936, South Korea
[7] Sungkyunkwan Univ, Dept Phys, Suwon 16419, South Korea
关键词
Visual cortex; RF coil; TORO coil; combined TRx coil; magnetic resonance imaging; functional MRI; TO-NOISE RATIO; FIELD STRENGTH; HEAD COIL; VISUALIZATION; PENETRATION; ABSORPTION; PATTERNS; DESIGN; LIMITS; PULSE;
D O I
10.1109/ACCESS.2022.3167422
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magnetic resonance imaging (MRI) using an ultra-high magnetic field (7 Tesla) enables detailed and non-invasive studies of the function and anatomy of the human visual cortex, which is the brain region responsible for visual signal processing. However, 7T human MRI often suffers from image shading in the occipital region due to the radiofrequency (RF) wave propagation effect. Dedicated visual cortex coils, on the other hand, often lack the capability to visualize the whole brain which is necessary for image registration. We propose a novel RF coil structure in which a 2-channel transmit and receive (TRx) coil is grafted onto the frontal part of a multi-channel transmit-only/receive-only (TORO, 4Tx/14Rx) visual cortex coil. This coil was tested for high-resolution functional MRI with an in-plane resolution of 0.5 mm. The results showed that the proposed coil achieved a higher (x2.5) temporal signal-to-noise ratio (tSNR) in functional imaging of the visual cortex area than that of a commercial 7T whole-head coil. The added 2-channel TRx elements allowed whole-brain edge images to be acquired, enabling successful brain segmentation and atlas registration without the need for a second scan using a whole-head coil. The proposed coil structure can be useful for high-resolution visual functional MRI at very high magnetic fields due to its sensitivity, open geometry, and compatibility with the standard image processing workflow.
引用
收藏
页码:42083 / 42093
页数:11
相关论文
共 23 条
  • [1] Unshielded asymmetric transmit-only and endorectal receive-only radiofrequency coil for 23Na MRI of the prostate at 3 tesla
    Farag, Adam
    Peterson, Justin Charles
    Szekeres, Trevor
    Bauman, Glenn
    Chin, Joseph
    Romagnoli, Cesare
    Bartha, Robert
    Scholl, Timothy J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 436 - 445
  • [2] Effective arrangement of separated transmit-only/receive-only RF coil for improvement of B1 homogeneity at 7 Tesla
    Im, Geun Ho
    Seo, Jeong-Hoon
    Kim, Kyoung-Nam
    Heo, Phil
    Chung, Julius Juhyun
    Jang, Moon-Sun
    Lee, Jung Hee
    Kim, Jae-Hun
    Kim, Sun I.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (05) : 616 - 624
  • [3] Transmit-only/receive-only radiofrequency coil configuration for hyperpolarized 129Xe MRI of rat lungs
    Doganay, Ozkan
    Thind, Kundan
    Wade, Trevor
    Ouriadov, Alexei
    Santyr, Giles E.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2015, 45 (03) : 115 - 124
  • [4] Effective arrangement of separated transmit-only/receive-only RF coil for improvement of B1 homogeneity at 7 Tesla
    Geun Ho Im
    Jeong-Hoon Seo
    Kyoung-Nam Kim
    Phil Heo
    Julius Juhyun Chung
    Moon-Sun Jang
    Jung Hee Lee
    Jae-Hun Kim
    Sun I. Kim
    Journal of the Korean Physical Society, 2014, 65 : 616 - 624
  • [5] A New Phased-Array Magnetic Resonance Imaging Receive-Only Coil for HBO2 Studies
    Mareyam, Azma
    Shank, Erik
    Wald, Lawrence L.
    Qin, Michael K.
    Bonmassar, Giorgio
    SENSORS, 2022, 22 (16)
  • [6] Magnetic field sensitivity at 7-T using dual-helmholtz transmit-only coil and 12-channel receive-only bended coil
    Kim, Kyoung-Nam
    Ryu, Yeunchul
    Seo, Jeung-Hoon
    Kim, Young-Bo
    SCANNING, 2016, 38 (06) : 515 - 524
  • [7] Transmit-Only/Receive-Only Radiofrequency System for Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs
    Giovannetti, G.
    Frijia, F.
    Hartwig, V.
    Menichetti, L.
    Positano, V.
    Ardenkjaer-Larsen, J. H.
    Lionetti, V.
    Aquaro, G. D.
    De Marchi, D.
    Schulte, R. F.
    Wiesinger, F.
    Landini, L.
    Lombardi, M.
    Santarelli, M. F.
    APPLIED MAGNETIC RESONANCE, 2013, 44 (10) : 1125 - 1138
  • [8] Transmit-Only/Receive-Only Radiofrequency System for Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs
    G. Giovannetti
    F. Frijia
    V. Hartwig
    L. Menichetti
    V. Positano
    J. H. Ardenkjaer-Larsen
    V. Lionetti
    G. D. Aquaro
    D. De Marchi
    R. F. Schulte
    F. Wiesinger
    L. Landini
    M. Lombardi
    M. F. Santarelli
    Applied Magnetic Resonance, 2013, 44 : 1125 - 1138
  • [9] Automated Tuning and Matching of a 16-Channel TEM Transmit-Only Array used in Conjunction with a 32-Channel Receive-Only Loop Array for MR Cardiac Imaging at 7 Tesla.
    Snyder, Carl J.
    DelaBarre, Lance
    Vaughan, J. Thomas
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (IMS), 2013,
  • [10] A Transmit/Receive Radiofrequency Array for Imaging the Carotid Arteries at 7 Tesla Coil Design and First In Vivo Results
    Kraff, Oliver
    Bitz, Andreas K.
    Breyer, Tobias
    Kruszona, Stefan
    Maderwald, Stefan
    Brote, Irina
    Gizewski, Elke R.
    Ladd, Mark E.
    Quick, Harald H.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 246 - 254